Anda di halaman 1dari 30

LAPORAN LABORATORIUM

PRAKTIKUM ELEKTRONIKA
PENGUJIAN BEBAN NOL TRANSFORMATOR 1 FASA
d
i
s
u
s
u
n
oleh :

NAMA : FEBRIANA RIZKY BR.HOMBING


KELAS : EL-4F
NIM : 1705033014

POLITEKNIK NEGERI MEDAN


JURUSAN ELEKTRO
PROGRAM STUDI TEKNIK LISTRIK
TA 2018/2019
LEMBAR PENILAIAN

JUDUL PERCOBAAN : Pengujian Beban Nol Transformator 1 Fasa

NO. PERCOBAAN : 04 (empat)

NAMA PERLAPOR : Febriana Rizky Br.Hombing

NIM : 1705033014

KELOMPOK : 01 (SATU)

NAMA PARTNER : Elga Theofani Ivana Pakpahan


Febriana Rizky Sihombing
Humaira Sari
Jesicca Ivana Putri

KELAS : EL - 4F.

TANGGAL PERCOBAAN : 29 MARET 2019

TANGGAL PENYERAHAN : 4 APRIL 2019

INSTRUKTUR :- Drs.ARFIAN
- JULI IRIANI MT

NILAI :

i
DAFTAR ISI

Lembar Penilaian..........................................................................................................i
Daftar Isi ..................................................................................................................... ii
1. Tujuan Percobaan............................................................................................. 1
2. Pendahuluan ..................................................................................................... 1
3. Alat dan Bahan yang Dibutuhkan .................................................................... 2
4. Rangkaian Percobaan ........................................................................................2
5. Tugas dan Pertanyaan .......................................................................................3
6. Tabel Evaluasi ...................................................................................................4
7. Analisis..............................................................................................................5
8. Jawaban .............................................................................................................8
9. Kesimpulan .....................................................................................................11
10. Saran ................................................................................................................12

ii
D. PENGUJIAN BEBAN NOL TRANSFORMATOR 1 FASA
1. Tujuan Percobaan .

Pada akhir percobaan diharapkan mahasiswa sebagai praktikan dapat :

 Menentukan rugi rugi beban nol atau rugi inti.

 Menentukan parameter R m , Xc , Ic , dan Im .

2. Pendahuluan.

Pada transformator terdapat rugi rugi daya yang terdiri dari rugi inti dan rugi tembaga.
Pengujian trafo pada kondisi tanpa beban atau tanpa beban nol dilakukan untuk memperoleh
rugi inti yang terjad, sedangkan untuk mengetahui rugi daya, dilakukan dengan pengujian
dalam kondisi beban atau hubung singkat.

Rangkaian ekivalen transformator dalam kondisi tanpa beban diperlihatkan pada


gambar dibawah ini.

Gambar I

Arus yang mengalir pada trafo pada kondisi tanpa beban disebut dengan arus penguat yang
terdiri dari:

 Arus penguatan ( Im ), yang aktif dapat menimbulkan rugi rugi besi atau inti.
 Arus yang timbul dikarenakan arus Eddy ( Edy Current ) dan histerisi, yang dikenal
dengan arus magnetisasi ( Im ) .

1
Dari gambar Ib , dapat ditentukan,

Arus beban nol :

I0 = √𝐼𝑐 2 + 𝐼𝑚 2

Dan 𝐼𝑚 = 𝐼0 sin

𝐼𝑚 = 𝐼0 cos

Pada keadaan beban nol nilai arus I0 relatif kecil akan menghasilkan rugi tembaga pada sisi
primer dapat diabaikan, sehingga rugi daya pada kondisi ini dianggap merupakan rugi rugi
inti saja.

3. Peralatan yang diperlukan.

a. Sumber tegangan arus bolak-balik 0 - 240 volt 1 buah


b. Transformator 1 fasa 220 Volt / 48 volt / 50 VA 1 buah
c. Voltmeter 2 buah
d. Wattmeter 1 buah
e. Amperemeter 1 buah
f. Kabel penghubung 15 buah
4. Rangkaian Percobaan.

2
5. Tugas dan pertanyaan
a. Buatlah rangkaian seperti gambar diatas.
b. Aturlah tegangan mulai dari tegangan nol hingga 120% tegangan nominalnya
(minimal 5 data pengukuran).
c. Catat dan masukkan data dalam tabel evaluasi nilai 𝑉1, 𝑉2, A dan W pada setiap
kenaikan tegangan.
d. Setelah selesai pengambilan data percobaan tentukanlah : rugi rugi beban nol dan nilai
parameter R c , Xm dan Im ada setiap pengukuran.

3
6. Tabel Evaluasi.
* Vm = 120 % x Vnominal

NO
𝑉1 𝑉2 I0 𝑃1 𝐼𝑐 𝐼𝑚 𝑅𝑐 𝑋𝑚 Cos 𝜃0
Volt Volt (mA) (Watt) Volt (mA) (kΩ) (kΩ) Cos 𝜃
1
2
3
4
5
6
7
8
9
10
11
12

4
7. Analisis

5
6
7
8. Jawaban

8
9
10
9. Kesimpulan

11
10. Saran

MEDAN, 4 APRIL 2019

Febriana Rizky Sihombing

12
LAPORAN LABORATORIUM
PRAKTIKUM ELEKTRONIKA

PENGUJIAN HUBUNG SINGKAT TRANSFORMATOR 1 FASA

d
i
s
u
s
u
n
oleh :

NAMA : FEBRIANA RIZKY BR.HOMBING


KELAS : EL-4F
NIM : 1705033014

POLITEKNIK NEGERI MEDAN


JURUSAN ELEKTRO
PROGRAM STUDI TEKNIK LISTRIK
TA 2019/2020
LEMBAR PENILAIAN

JUDUL PERCOBAAN : Pengujian Hubung Singkat Transformator 1 Fasa

NO. PERCOBAAN : 05 (lima)

NAMA PERLAPOR : Febriana Rizky Br.Hombing

NIM : 1705033014

KELOMPOK : 01 (SATU)

NAMA PARTNER : Elga Theofani Ivana Pakpahan


Febriana Rizky Sihombing
Humaira Sari
Jesicca Ivana Putri

KELAS : EL - 4F.

TANGGAL PERCOBAAN : 29 MARET 2019

TANGGAL PENYERAHAN : 4 APRIL 2019

INSTRUKTUR :- Drs.ARFIAN
- JULI IRIANI MT

NILAI :

i
DAFTAR ISI

Lembar Penilaian..........................................................................................................i
Daftar Isi ..................................................................................................................... ii
1. Tujuan Percobaan................................................................................................... 1
2. Pendahuluan ........................................................................................................... 1
3. Alat dan Bahan yang Dibutuhkan .......................................................................... 2
4. Rangkaian Percobaan ..............................................................................................2
5. Tugas dan Pertanyaan .............................................................................................3
6. Tabel Evaluasi .........................................................................................................4
7. Analisis ...................................................................................................................5
8. Jawaban ...................................................................................................................8
9. Kesimpulan ...........................................................................................................11
10. Saran .....................................................................................................................12

ii
E. PENGUJIAN HUBUNG SINGKAT TRANSFORMATOR 1 FASA
1. Tujuan Percobaan .

Pada akhir percobaan diharapkan praktikan dapat :

 Menentukan presentase tegangan hubung singkat terhadap tegangan nominal.


 Menentukan rugi tembaga (𝑃𝑐𝑢 ) transformator .
 Menentukan konstanta tahanan ekivalen (𝑅𝑒𝑘 ) dan reaktansi ekivalen (𝑋𝑒𝑘 ) .

2. Pendahuluan.

Untuk mengetahui persentase tegangan sisi primer pada saat terjadi hubungan singkat
suatu transformator terhadap tegangan nominal maka dapat ditentukan dengan persamaan :

𝑉ℎ𝑠
𝑉ℎ𝑠 (%) = 𝑉𝑛
× 100 %......................................................(1)

Dari persamaan persentase tegangan hubung singkat terhadap tegangan nominalnya


tersebut dapat diketahui besarnya arus hubung singkat yang terjadi bila transformator bekerja
pada tegangan nominal.

Karena pada percobaan pengujian transformator dalam kondisi hubung singkat tegangan
primer adalah relatif kecil buka kurung kira-kira hingga 15% dari tegangan nominalnya,
maka mutual fluks yang dihasilkan oleh inti transformator dapat diabaikan. Sehingga
rangkaian pengganti sebuah transformator dalam keadaan hubung singkat dapat digambarkan
seperti gambar dibawah ini :

1
Dari rangkaian pengganti transformator yang diperlihatkan pada gambar diatas dapat
ditentukan besarnya rugi tembaga dan konstanta pada kondisi beban nominal, yaitu dapat
ditulis :

Pcu = PHS = Daya hubung singkat

𝑉𝑖𝑛
𝑍𝑒𝑘 = ………………………………. (2)
𝑉𝐻𝑆

𝑃ℎ𝑠
𝑅𝑒𝑘 = ………………………………. (3)
𝐼𝐻𝑆 2

𝑋𝑒𝑘 = √( 𝑍𝑒𝑘 2 − 𝑅𝑒𝑘 2)………………….(4)

Dari nilai konstanta 𝑅𝑒𝑘 dan 𝑋𝑒𝑘 dan ini dapat pula ditentukan rugi tegangan pada
transformator pada saat kondisi beban.

3. Peralatan yang Diperlukan.

a. Sumber tegangan AC 0 - 240 volt 1 buah


b. Transformator 1 fasa 228 volt 1 buah
c. Voltmeter AC 1 buah
d. Amperemeter AC 2buah
e. Watt meter AC 1buah
f. Kabel penghubung 15 buah

4. Rangkaian Percobaan.

2
5. Tugas dan Pertanyaan.

a. Buatlah rangkaian percobaan seperti gambar diatas.


b. Amati hasil pengukuran V1 , I1 , I2 dan P, kemudian isikan pada tabel evaluasi.
c. Tentukan persentase tegangan hubung singkat terhadap tegangan nominal, tahanan
ekivalen (R ek ) dan reaktansi ekivalen (Xek ) .
d. Tentukan perbedaan besar rugi tembaga antara pengukuran daya hubung singkat dan
jumlah rugi tembaga kedua sisi transformator (I1 2 . R1 + I2 2 . R 2 ) , Jelaskan mengapa
berbeda ?
e. Buktikan bahwa hubungan antar rugi tembaga dengan daya semu (VA) beban adalah
berbanding kuadratis.
f. Dengan menggunakan hubungan pada item (e di atas, tentukan rugi tembaga pada
kondisi 2/3 penuh.
g. Tentukan arus hubung singkat pada sisi tegangan rendah terbesar dari transformator
bila sisi tegangan tinggi bertegangan nominal.
h. Buatlah kesimpulan dari percobaan ini.
i. Sebagai catatan, usahakan menunjukkan alat ukur mendekati pada keadaan yang
sebenarnya, ukur tahanan R1 dan R 2 ) dengan ohm meter, pengukuran arus hubung
singkat dapat dilakukan 120% nominal arus pada sisi sekundernya.

3
6. Tabel Evaluasi.

NO 𝑉in I1 I2 P
( Volt ) ( Ampere ) ( Ampere ) ( Watt )
1
2
3
4
5
6
7
8
9
10

4
7. Analisis

5
6
7
8. Jawaban

8
9
10
9. Kesimpulan

11
10. Saran

MEDAN, 4 APRIL 2019

Febriana Rizky Sihombing

12