Anda di halaman 1dari 1

NOTE: PROVIDE CLEAN OUT FOR CENTRAL WASTE WATER TREATMENT FACILITY ( WWTF)

THE CONTROL APPROACHES AND


MERGING SECTION AND / OR MANSASA & LIBERTAD SUBDIVISION
POSSIBLE CHECK POINT OF SEWER LINE
PROVINCE OF BOHOL PHILIPPINES

SAMPLES OF HOPE
INSTALLED LINER

4 CHAMBER WASTE WATER TREATMENT


6" PVC PIPE FACILITY ( W W T F )
SEWAGE
IRRIGATION
DELIVERY PIPE CHECKERED PLATE
MANHOLE 6" PVC PIPE
USAGE
COVER SLUDGE RETURN LINE

SAMPLING
CLEAN OUT &
MONITORING
TANK TANK
SEWAGE COARSE BUBBLE
DELIVERY PIPE
DIFFUSER
2.00

WASTE WATER TREATMENT


SUBMERSIBLE
6" PVC PIPE PUMP
SLUDGE
SETTLING

SLOPE

SAMPLES OF HOPE
UNIT INSTALLED SIDE ELEVATION
INSTALLED LINER DETAILED DRAWING
PLASTIC S.V.

17.00 IRRIGATION
USAGE
6" PVC PIPE 0.20
0.20 1.50 SLUDGE RETURN LINE

CHLORINE TANK
MANUAL
SEWAGE
DELIVERY PIPE

CLEAN OUT TANK


3.00

3.00
6" PVC PIPE 6" PVC PIPE 6" PVC PIPE 6" PVC PIPE
6" PVC PIPE
SUBMERSIBLE
PUMP
1 UNIT 5 HP ROOT BLOWER
SEWAGE OR
DELIVERY PIPE
1 UNIT 3 HP ROOT BLOWER

0.20 0.20 0.20


4.00 4.00 4.00 4.00
0.20
1 TOP VIEW
A 1 SCALE 1 : 100 METERS

CHLORINE TANK
SEWAGE
IRRIGATION MANUAL
DELIVERY PIPE CHECKERED PLATE
MANHOLE 6" PVC PIPE
USAGE
COVER SLUDGE RETURN LINE

SAMPLING
CLEAN OUT &
MONITORING
TANK TANK
SEWAGE COARSE BUBBLE
DELIVERY PIPE
DIFFUSER
2.00

SUBMERSIBLE
6" PVC PIPE PUMP
SLUDGE
SETTLING

SLOPE

1 UNIT 5 HP ROOT BLOWER


OR
1 UNIT 3 HP ROOT BLOWER

1 SIDE ELEVATION
A 2 SCALE 1 : 100 METERS

CERTIFYING PROFESSIONAL
RA 9266 SECTION 33 PROPOSED PROJECT : MANSASA PROJECT OWNER : MANSASA & LIBERTAD SUBDIVISION PRINCIPAL DESIGNER : ENGR. ANTONIO N. ATILLO REG. M.E. SEAL SET SHEET
Drawings and specifications and
other contract documents duly signed, LIBERTAD SUBDIVISION
stamped or sealed, as instruments of
service, are the intellectual property
and documents of the architect,

No. 5 Virgo St, Pleasant Homes Subd. Bo.


Punta Princesa , Cebu City 6000
whether the object for which they are
made is executed or not. It shall be
unlawful for any person to duplicate
or make copies of said documents for
TYPICAL SEWERAGE LINE GRADING
FOR THE ALTHARRA SUBDIVISION
( MANSASA & LIBERTAD)
WASTE WATER TREATMENT
REG.
NO.
PTR.
NO.
TIN.
NO.
use in the repetition of and for other
projects or buildings, whether
executed partly or in whole, without
FACILITY ( WWTF ) DRAWN BY: EDISON P. ALFAFARA DATE : March . 9 , 2019
the written consent of the architect or
DATE DATE DATE author of said documents. LOCATION: PROVINCE OF BOHOL PHILIPPINES ADDRESS : PROVINCE OF BOHOL PHILIPPINES ADDRESS: BOGO CITY , CEBU DATE : 3.9,2019

Anda mungkin juga menyukai