Anda di halaman 1dari 53

FactoryTalk® View Studio v8.

0
Kendal Connection Live

January 2015

PUBLIC INFORMATION

Rev 5058-CO900E Copyright © 2014 Rockwell Automation, Inc. All Rights Reserved.
Agenda

FactoryTalk View Studio 8.0

RF Ideas Rockwell Reader

InView NEW Comms Module and Web-based Programming

PUBLIC INFORMATION Copyright © 2014 Rockwell Automation, Inc. All Rights Reserved.
FactoryTalk View Machine Edition 8.0
August 2014 Release

Configuration and Improved Run-Time Expanded Operating Streamlined


Application Building Experience System Support Installation
• Simplified project • User Management • Windows 8 • Unattended Install
management controls • Windows 8.1 • Uninstall
• Resizable alarm • Improved Domain Update FactoryTalk View
editor Authentication • Windows 2012 Tool
• Application • Security Code Server R2
Manager workflow changes • Last release
• Improved audit trail supporting older
• User Group Microsoft
Security functions Operating Systems
• Application loading & FactoryTalk View
Error-proofing Machine Edition
versions
• Unsolicited
Messages

Support for PanelView Plus 7 Terminals


PUBLIC INFORMATION Copyright © 2014 Rockwell Automation, Inc. All Rights Reserved. 3
Summary of Release
 Products and Services Released:
 FactoryTalk View Site Edition 8.0
 FactoryTalk View Machine Edition 8.0
 FactoryTalk ViewPoint 8.0
 FactoryTalk Services Platform 2.70
 FactoryTalk Alarms and Events 2.70
 RSLinx Enterprise 5.70
 RSLinx Classic 3.70
 FactoryTalk Activation 3.62.01

PUBLIC INFORMATION Copyright © 2014 Rockwell Automation, Inc. All Rights Reserved. 4
PanelView™ Plus 7
High-level Introduction

PUBLIC INFORMATION Copyright © 2014 Rockwell Automation, Inc. All Rights Reserved. 6
PanelView Plus 7
Introduction

Optimized value with two distinct platforms


 New Displays
 Increased Screen resolution
 Wide Screens
 More Sizes – Up To 19”
 More Certifications
 ATEX
 INMETRO
 Marine

Better hardware, easy migration!


PUBLIC INFORMATION Copyright © 2014 Rockwell Automation, Inc. All Rights Reserved. 7
PanelView Plus 7
Standard vs. Performance
PvP7 - Standard PvP7 - Performance
Avail Sizes (in): Avail Sizes (in):
4.3W, 5.7, 6.5, 9.0W, 10.4 6.5, 9.0W, 10.4,
12.1W, 15.0, 19.0

AFC: Jan, 2015 AFC: Q3, 2015


Housing & Bezel Material Plastic Aluminum

Communication Single Ethernet Dual port Ethernet, embedded DLR

Op. System / Software Windows CE 6.0 w/standard features set Windows CE 6.0 w/extended features set
FTView ME 7.0 FTView ME 8.10
Application limits: 1 Controller, 25 Screens, 200 Application limits: None
Alarms

Processor / Memory ARM / 512 MB flash and RAM X86 / 1 GB flash, 512 MB RAM

Power Options DC only AC and DC

User Interface Resistive, touch screen only Resistive, touch or touch/keypad combo

Certs UL, CE UL, CE, Marine,


(future: ATEX, INMETRO, Conformal Coating)

PUBLIC INFORMATION Copyright © 2014 Rockwell Automation, Inc. All Rights Reserved. 8
Configuration and Application Building
FactoryTalk View Machine Edition 8.0 Feature Information

PUBLIC INFORMATION Copyright © 2014 Rockwell Automation, Inc. All Rights Reserved.
How Security Works prior to View 8.00

PUBLIC INFORMATION Copyright © 2014 Rockwell Automation, Inc. All Rights Reserved.
How Security Works prior to View 8.00

Project Project Project


A B C

RSLinx
Users & Groups Config.

Public Local FactoryTalk Directory

PUBLIC INFORMATION Copyright © 2014 Rockwell Automation, Inc. All Rights Reserved. 11
How Security Works in View 8.00

PUBLIC INFORMATION Copyright © 2014 Rockwell Automation, Inc. All Rights Reserved.
VME
Simplified Project Maintenance

Overview
• Improved handling of multiple
FactoryTalk View Machine Edition
applications on same PC
• Each project has its own private security
configuration
• Users, Groups, and policy

Benefits
• Allows user to restore a project
(MER/APA) without overwriting any other
project’s security configuration
• No need to be ‘careful’ when restoring
MER or APA
PUBLIC INFORMATION Copyright © 2014 Rockwell Automation, Inc. All Rights Reserved. 13
FT Talk Directory Review
 Same way of configuring security as before.
 Improved handling of multiple FTView Machine Editions applications on
same PC
 Each project has its own private security configuration
 Allows user to restore a project (MER/APA) without overwriting any
other project’s security configuration

 FT Admin console cannot access security settings of ME 8.0 projects

PUBLIC INFORMATION Copyright © 2014 Rockwell Automation, Inc. All Rights Reserved. 14
VME
Resizable Alarm Editor

Overview
• Alarm Editor allows resizing of the
various tables in the dialog

Benefits
• Easier to manage and configure Alarms

PUBLIC INFORMATION Copyright © 2014 Rockwell Automation, Inc. All Rights Reserved. 15
VME
Application Manager Workflow

Overview
• Application Manager returns to starting
step when an operation completes
• Application Manager allows user to
overwrite existing
• backup (APA) files when creating a
backup file
• project when restoring a backup (APA)
or runtime (MER) file

Benefits
• Allows user to immediately initiate next
operation saving time

PUBLIC INFORMATION Copyright © 2014 Rockwell Automation, Inc. All Rights Reserved. 16
Improved Run-Time Experience
FactoryTalk View Machine Edition 8.0 Feature Information

PUBLIC INFORMATION Copyright © 2014 Rockwell Automation, Inc. All Rights Reserved. 17
VME
Run-time User Management
Overview
• New objects to manage native
FactoryTalk and Windows-linked users
• Add, Delete, Change Group, Enable,
Disable, Unlock, Change Account
Properties, Change Password
• Add, remove, and modify user accounts
while an MER is running
• Security configuration changes persisted
in the MER

Benefits
• No longer need to rebuild MER to
change security configuration
• Once an application is deployed on a
PVP, View Studio is no longer required
for most security modifications to the
project
PUBLIC INFORMATION Copyright © 2014 Rockwell Automation, Inc. All Rights Reserved. 19
VME
Administrative Change Password

Overview
• Change Password button modified to
add an Administrative mode, that allows
user’s with access to change ANY user
password
• Security configuration changes persisted
in the MER

Benefits
• Prevents users being ‘locked’ out of
system by a malicious actor
• More administrative control of user
account passwords

PUBLIC INFORMATION Copyright © 2014 Rockwell Automation, Inc. All Rights Reserved. 20
Domain Authentication before v8.0
 Domain authentication only supports Windows 2000, Windows 2003
mixed-mode, and Windows 2003 native-mode domains
 Requires changes to domain policies to work
 Successful configuration was time-consuming; often customers could
not get it to work
 Extensive Knowbase article covers setup and known constraints

 No support for Windows 2008 or Windows 2012 domains

PUBLIC INFORMATION Copyright © 2014 Rockwell Automation, Inc. All Rights Reserved. 21
Windows 2008 and 2012 Server VME
Active Directory Authentication Support

Overview

• Added LDAP and LDAP over SSL to the


PanelView Plus terminals (Lightweight
Directory Access Protocol)
• Existing application will work in Windows
2008/2012 domains, unchanged
• LDAP configuration applies to the
terminal, not the application
• Operation transparent to Operator/User

Benefits

• Windows-linked user and groups support


centralized account management
• Support for 21 CFR Part 11 compliance
PUBLIC INFORMATION Copyright © 2014 Rockwell Automation, Inc. All Rights Reserved. 23
Domain Review
 Support Windows Server 2008 & 2012
Domain authentication
 Domain must support LDAP
 Additional LDAP configuration in ME
Station
 Supports LDAP or LDAP Over SSL
 LDAP Over SSL encrypts the user
credentials
 LDAP over SSL requires certificate to be
moved (manually) to terminal

 Engineering workstation (View Studio) does not have to be part of the same
domain controller.
 Windows CE does not cache credentials.

PUBLIC INFORMATION Copyright © 2014 Rockwell Automation, Inc. All Rights Reserved. 24
Login Button Improvements Support VME
Domain Integration

Overview
• Enhanced login button supports
• Control of domain field visibility
• Allow/ Disallow domain field editing
• Domain field content can be fixed, user
entered, or bound to a tag
• Obscure user name entry with ‘#’

Benefits
• Saves operator time
• Requires less Operator knowledge

PUBLIC INFORMATION Copyright © 2014 Rockwell Automation, Inc. All Rights Reserved. 25
VME
Changes to A-P Security Codes
 Assume a user is a member of
more than one group. The Overview
groups have the following
• All of a user’s A-P configurations are
configured security codes ANDed together in v8.0, and later
Runtime Security Configuration A B C D
• If a user is a member of more than one
A-P configuration, at run-time the user’s
Group1 X X X effective A-P Security Code permissions
Group2 X X X will be the most restricted set
• previous versions granted the most
At run-time the user’s effective lenient effective Security Code A-P
security codes have changed in permissions
v8.0 and later, compared to
earlier versions Benefits
Effective A-P Security Codes A B C D

FactoryTalk View v8.0 X X

FactoryTalk View v7.0, and earlier X X X X


• Support for 21 CFR Part 11 compliance

PUBLIC INFORMATION Copyright © 2014 Rockwell Automation, Inc. All Rights Reserved. 26
VME
Capture Value Before Change VSE

Overview
• When you change the numeric or string
input value, the previous value is logged
and shown in the FactoryTalk
FactoryTalk AssetCentre AssetCentre Audit Log
Audit Log View

Benefits
• Provides improved tracking of operator
actions
• Improves support for 21 CFR Part 11
Audit Message Detail
compliance
• Streamlines troubleshooting process

PUBLIC INFORMATION Copyright © 2014 Rockwell Automation, Inc. All Rights Reserved.
VME
New User Group Security Function VSE

Overview
• CurrentUserHasGroup() – Returns
True/False whether the current user is
assigned to the specified FactoryTalk
user group
• Example usage
CurrentUserHasGroup() security
CurrentUserHasGroup(“Engineers”)
function

Benefits
• Enables evaluation of a user’s
membership in a security group from a
display screen

PUBLIC INFORMATION Copyright © 2014 Rockwell Automation, Inc. All Rights Reserved. 28
VME
Improved System Error-proofing

Overview

• When building MER system warns if a


shortcut uses an unsupported network,
Ex. RIO
• When loading MER on PanelView Plus
terminal will warn if
• MER project resolution (size or aspect
ratio) does not match physical terminal
• MER shortcut(s) references a network
the terminal cannot support,
Ex. PanelView Plus 7 and DH+

Benefits

• Saves wasted time


PUBLIC INFORMATION Copyright © 2014 Rockwell Automation, Inc. All Rights Reserved. 29
RSLinx Enterprise Accepts VME
Unsolicited Messages VSE

Overview
• Controllers send Direct Tag information
to HMI application under programmatic
control
• Control program determines when
information is transmitted to HMI

Benefits
• Unsolicited messages can be used to
reduce network traffic for ‘exception’
events (Ex. Alarms)
• Normal tag data is polled, or solicited,
from the controller

PUBLIC INFORMATION Copyright © 2014 Rockwell Automation, Inc. All Rights Reserved. 30
Streamlined Installation
FactoryTalk View Machine Edition 8.0 Feature Information

PUBLIC INFORMATION Copyright © 2014 Rockwell Automation, Inc. All Rights Reserved.
VME
Unattended installation VSE

Overview

• Use scripting in a command line or batch


file to automate installation of all
FactoryTalk View components

Use a batch file


(.bat) to automate
installation Benefits

• Use during large-scale rollouts when it is


too costly to have resources interactively
install the software on individual PCs
• During installation, instead of prompting
you for information interactively, the
process follows the specified parameters
PUBLIC INFORMATION Copyright © 2014 Rockwell Automation, Inc. All Rights Reserved. 32
VME
Uninstall FactoryTalk View Tool VSE

Overview
• Use the tool to uninstall FactoryTalk View
components that are already installed on
your computer

Benefits
• A more direct method to uninstalling
FactoryTalk View and related
dependencies

PUBLIC INFORMATION Copyright © 2014 Rockwell Automation, Inc. All Rights Reserved. 33
VME
Error-proofing Installation VSE

Overview

• Prevents FactoryTalk View products from


installing on to any PC running an
unsupported Microsoft Operating System
Examples (not a comprehensive list)
• Windows XP SP1
• Windows 98
• Windows 2000 Server
• Windows NT

Benefits

• Saves wasted time and resources


• Reduce frustration

PUBLIC INFORMATION Copyright © 2014 Rockwell Automation, Inc. All Rights Reserved. 34
Expanded Operating System Support
FactoryTalk View Machine Edition 8.0 Feature Information

PUBLIC INFORMATION Copyright © 2014 Rockwell Automation, Inc. All Rights Reserved.
Expanded Operating System VME
Support VSE

Windows 8, Windows 8.1 Update and Windows 2012 Server R2


join the list of supported operating systems in this release.

PUBLIC INFORMATION Copyright © 2014 Rockwell Automation, Inc. All Rights Reserved. 36
Additional PanelView Plus VME
Platform Support
 PanelView Plus Platforms
 PanelView Plus 6 Compact 1000
 PanelView Plus 7 Standard
 PanelView Plus 7 Performance

PUBLIC INFORMATION Copyright © 2014 Rockwell Automation, Inc. All Rights Reserved. 37
Removing Operating System VME
Support VSE

 FactoryTalk View v8.0 is the LAST release to support


 Windows XP [any edition or SP]
 Windows Vista [any edition or SP]
 Windows 2003 Server [any edition or SP]

PUBLIC INFORMATION Copyright © 2014 Rockwell Automation, Inc. All Rights Reserved. 38
Removing PanelView Plus VME
Platform Support
 FactoryTalk View 8.0 is the LAST release to support v 3.2 and v4.0 MER
 Using release after v8.0, it is not possible to create v3.2 or v4.0 MER
 Using release after v8.0, it is not possible to execute v3.2 or v4.0 MER
 Using release after v8.0, it IS possible to open and convert legacy
applications the newer project format

PUBLIC INFORMATION Copyright © 2014 Rockwell Automation, Inc. All Rights Reserved. 39
FactoryTalk View 8.00
RF IDeas Rockwell Reader

PUBLIC INFORMATION Copyright © 2014 Rockwell Automation, Inc. All Rights Reserved.
Rockwell Reader Overview

PUBLIC INFORMATION Copyright © 2014 Rockwell Automation, Inc. All Rights Reserved.
RF IDeas Workflow Optimization
Benefits Applications
• Compliance  Operator ID in Manufacturing
• Security  Industrial Dispensing/Tool Cribs
• Safety  Attendance Management
• Workflow Improvement
 Secure Print Release
• Combine employee
identification to process &  Computer Logon
material

PUBLIC INFORMATION Copyright © 2014 Rockwell Automation, Inc. All Rights Reserved.
ROI of Workflow Improvement
Users of RF IDeas solutions benefit with savings of up to 15 minutes per
employee per week.
Scenario:
 1,000 employee facility or company
 15 times average sign-on per employee per day
 15 seconds per manual sign on vs. 3 seconds per badge sign on = 3 minutes
saved per employee per day
 250 employee hours saved per week. Average annual salary of $50,000 =
$300,000+ saved per year

PUBLIC INFORMATION Copyright © 2014 Rockwell Automation, Inc. All Rights Reserved.
Auto-Locking Presence Detector
 pcProx Sonar
 Compliments ANY logon solution
 Walk-up and Walk-Away Keystrokes
 Lock, Logoff, Run Script
 Range 2-5 feet
 USB Plug-n-Play
 No Software required

 USB proxMat
 Detects user on mat
 USB Keystrokes on Walk-up or Walk-Away

PUBLIC INFORMATION Copyright © 2014 Rockwell Automation, Inc. All Rights Reserved.
Where We Are

Over 80% of Fortune 100 Companies use RF IDeas Products

PUBLIC INFORMATION Copyright © 2014 Rockwell Automation, Inc. All Rights Reserved.
RF IDeas Rockwell Reader Overview

 The pcProx Plus connects to PVP6 1000 via USB.


 The gray units are configured out of box to work with the PVP login prompt.
 Username is the card ID (usually printed on the card)
 Password is a generated number based on all information on the card.
 If you don’t want to manually enter the user information when adding a new
user, we have 1 red unit that we can all share to be used as an enroll unit.

PUBLIC INFORMATION Copyright © 2014 Rockwell Automation, Inc. All Rights Reserved. 46
RE-CAP

 pcProx Plus connects to PVP6 1000 via USB. It mimics a keyboard, so no


special plug and play drivers are required.
 The units with RA in the catalog numbers work with the PVP login prompt
out of box.
 Configuration changes to the reader are done using a free tool that can be
downloaded from RF Ideas.

Workflow Improvement

PUBLIC INFORMATION Copyright © 2014 Rockwell Automation, Inc. All Rights Reserved. 47
Login Unit default Configuration

PUBLIC INFORMATION Copyright © 2014 Rockwell Automation, Inc. All Rights Reserved. 48
Enroll Unit Default Configuration

PUBLIC INFORMATION Copyright © 2014 Rockwell Automation, Inc. All Rights Reserved. 49
Changing Configuration
 LUID = 0
 The Reader is setup to be single
authentication

 LUID = 1
 The Reader is setup to be dual
authentication

 LUID = 2
 The Reader is setup to be in enroll
mode.

 Looking to add more for View SE and


other Rockwell software login prompts.

PUBLIC INFORMATION Copyright © 2014 Rockwell Automation, Inc. All Rights Reserved. 50
InView New Web-based Programming
Using the new Comms Module

PUBLIC INFORMATION Copyright © 2014 Rockwell Automation, Inc. All Rights Reserved.
PUBLIC INFORMATION

Rev 5058-CO900E Copyright © 2014 Rockwell Automation, Inc. All Rights Reserved.
INVIEW COMMS MODULE
WEBPAGE

New
The new Spectrum InView comms webpage replaces the
old Rockwell IMS configuration software.

Improved
Clean-sheet design for improved ease of use.

PUBLIC INFORMATION Copyright © 2014 Rockwell Automation, Inc. All Rights Reserved.
OLD Software LAYOUT

Complex & Difficult

All setting for all controller types at all times

Compatible with Windows XP only

PUBLIC INFORMATION Copyright © 2014 Rockwell Automation, Inc. All Rights Reserved.
NEW Software LAYOUT
Intuitive & Easy-to-use

Web-based & OS independent

Served from the Comms Module, no install


required

Only relevant settings are presented to the user


(unlike the old IMS software)

PUBLIC INFORMATION Copyright © 2014 Rockwell Automation, Inc. All Rights Reserved.
Thank You

PUBLIC INFORMATION

Follow ROKAutomation on Facebook & Twitter.


Connect with us on LinkedIn.

www.rockwellautomation.com

Rev 5058-CO900F Copyright © 2014 Rockwell Automation, Inc. All Rights Reserved.