28 Jln Buroh

based on NA A1.1
Gk - dead load
Qk - imposed y0 1 storage condition because arch drwg refer as warehouse concrete cover defineas fo
Rk - roof imposed load y0 0.7 roof
Wk - Wind load y0 0.5 wind
EHL- imperfection consider as 1.35Gk+1.5Qk, that why EHF gf = 1.0

Combination 1, general formula

Comb 1 1.35Gk + 1.5Qk +1.5Rk +1.5*y0*Wk +EHF case 1 as wind load has both direction X, Y. similar apply to EHF
Str. / ultmate 1.35Gk + 1.5Qk +1.5Rk +0.75Wk +EHF

1.35Gk + 1.5*y0*Qk +1.5*y0*Rk +1.5Wk +EHF case 2


1.35Gk + 1.5Qk +1.05Rk +1.5Wk +EHF

Combination 2, geotechnical consideration for pile, footing


Comb 2 1.0Gk + 1.3Qk +1.3Rk +1.3*y0*Wk +EHF case 1 as wind load has both direction X, Y. similar apply to EHF
Geotechnical 1.0Gk + 1.3Qk +1.3Rk +0.65Wk +EHF

1.0Gk + 1.3Qk +1.3Rk +1.3*y0*Wk +EHF case 1


1.0Gk + 1.3Qk +0.91Rk +1.3Wk +EHF

comb 1 condition Structuraal design on element


Primary Load Case nos 1 2 3 3 4 5 6 7 8 9 10

Load Case Wind Wind Wind Wind


direct X direct X direct Y direct Y
Dead LoadLive Load Live Load 0 deg 0 deg 180 deg 180 deg this group of column load
ULS
WL180 WL180
Gk Qk Rk Wk0 +x1 Wk0 -x2 +Y3 -Y4 EHFx EHF-x EHFy EHF-y
Comb load case 100 1.35 1.5 1.5 0 0 0 0 0 0 0 0
Comb load case 111 1.35 1.5 1.5 0.75 1
Comb load case 112 1.35 1.5 1.5 0.75 1
Comb load case 113 1.35 1.5 1.5 0.75 1
Comb load case 114 1.35 1.5 1.5 0.75 1
Comb load case 201 1.35 1.5 1.05 1.5 1
Comb load case 202 1.35 1.5 1.05 1.5 1
Comb load case 203 1.35 1.5 1.05 1.5 1
Comb load case 204 1.35 1.5 1.05 1.5 1

comb 2 condition geotechnical


Primary Load Case nos 1 2 3 3 4 5 6 7 8 9 10

Load Case Wind Wind Wind Wind


direct X direct X direct Y direct Y
Dead LoadLive Load Live Load 0 deg 0 deg 180 deg 180 deg this group of column load
ULS
WL180 WL180
Gk Qk Rk Wk0 +x1 Wk0 -x2 +Y3 -Y4 EHFx EHF-x EHFy EHF-y
Comb load case 100 1 1.3 1.3 0 0 0 0 0 0 0 0
Comb load case 111 1 1.3 1.3 0.65 1
Comb load case 112 1 1.3 1.3 0.65 1
Comb load case 113 1 1.3 1.3 0.65 1
Comb load case 114 1 1.3 1.3 0.65 1
Comb load case 201 1 1 0.91 1.3 1
Comb load case 202 1 1 0.91 1.3 1
Comb load case 203 1 1 0.91 1.3 1
Comb load case 204 1 1 0.91 1.3 1
based on EC2 part Fire resistace
concrete cover defineas follow: column 75mm
Beam 50mm
slab 50mm

ilar apply to EHF

ilar apply to EHF

this group of column load at foundation will compare with pile capcity (comb 2)
this group of column load at foundation will compare with pile capcity (comb 2)