REFERENCE DRAWINGS DWG NO.

1 1
ADDITIONAL BARS DELETED

b1 b2 b3 b4 b5 b6 b7 b8 b9 KEY PLAN:

NOTES:
1. COUPLERS TO BE USED FOR LAPPING ALL SLAB REINFORCEMENT AND EMBEDMENT TO WALL AND COLUMNS.
2. IF THE BAR DIAMETER IS CHANGING (MESH OR EXTRA BARS), COUPLERS WITH REDUCER TO BE USED.
IN SUCH CASES THE LOCATION OF COUPLER TO BE LOCATED AT A DISTANCE OF "LD OF SMALLER BAR"
FROM THE LOCATION SHOWN IN PLAN, TOWARDS THE DIRECTION OF SMALLER BARS.
2 3. SIFFNER TO BE PROVIDED TO CONNECT THE FLANGE AT A SPACING OF 150MM. 2
TOWER B

TOWER A

NOTE:
1. DO NOT SCALE FROM DRAWINGS. DIMENSIONS GOVERN.
2. ALL DIMENSIONS TO BE VERIFIED ON SITE.
3. ALL DIMENSIONS ARE IN MILLIMETERS UNLESS NOTED OTHERWISE.
4. ALL LEVELS ARE IN METERS UNLESS NOTED OTHERWISE.
5. THIS DRAWING MUST BE READ IN CONJUNCTION WITH ALL
RELEVANT PROJECT SPECIFICATIONS, SCHEDULES AND DRAWINGS.
bF 6. ANY DISCREPANCY IN OR BETWEEN THE DRAWINGS,
SPECIFICATIONS AND SCHEDULES MUST BE BROUGHT TO THE
IMMEDIATE ATTENTION OF THE ARCHITECT/ENGINEER PRIOR
3 PSR-1 PSR-1 TO UNDERTAKING ANY WORKS. 3
bE
7. THE CONTRACTOR SHALL SUBMIT COORDINATED SHOP
DRAWINGS FOR APPROVAL (BASED ON SITE DIMENSIONS)
PRIOR TO COMMENCEMENT OF ANY SITE WORKS OR PLACING
OF ANY ORDERS AND OR MANUFACTURE OF ANY FITTINGS,
FIXTURES AND COMPONENTS SHOWN. THE CONTRACTOR
SHALL ONLY WORK FROM COORDINATED AND APPROVED SHOP
Ld Ld DRAWINGS
8. ALL MATERIALS SHALL BE APPROVED BY THE ARCHITECT/
ENGINEER PRIOR TO UNDERTAKING ANY WORKS.
9. THE INFORMATION CONTAINED HEREIN IS PROVIDED ONLY TO
COMMUNICATE DESIGN INTENT.
10.THIS DRAWING SHALL BE READ IN CONJUCTION WITH OTHER
RELEVANT ARCHITECTURAL, STRUCTURAL, MECHANICAL, AND
ELECTRICAL DRAWINGS AND ALL RELEVANT SPECIFICATION.
T25-150 (TOP)
T20-150 (BOTTOM)
2750

2750
Ld MESH BOTHWAYS
2000

2000
Ld
4 PSR-4 4
bD PSR-4
2000

2000
2750

2750
T16-150 (TOP) DETAIL-D
T20-150(BOTTOM)
MESH BOTHWAYS
2000 2000

T20-150 (T&B)
MESH BOTHWAYS

T20-150 (T&B)
MESH BOTHWAYS
T20-150 (T&B)
T16-150 (T&B) MESH BOTHWAYS T16-150 (T&B)
5 MESH BOTHWAYS T20-150 (T&B) T20-150 (T&B) MESH BOTHWAYS 5
T20-150 (TOP) REINF. AS PER PLAN LINK LEVEL 05 (ROOF)
MESH BOTHWAYS MESH BOTHWAYS
T16-150(BOTTOM) +125.600 SSL +125.600 m
MESH BOTHWAYS
2750

2750
2000

2000
REBAR UPTO
Ld DETAIL-B WALL FACE (TYP.) Ld
PSR-4 PSR-4
bC 2-2 2-2
TB-29F-S-01712 TB-29F-S-01712
ALL BOTTOM Y DIRECTION BAR TO BE
2000

2000
2750

2750
(3r CONNECTED WITH WELDED COUPLER (3r
R) d TO EMBEDED STEEL SECTION. R) d
YE LA YE LA
d LA YE
R) d LA YE
R)
6 2000 (3r 10T32-150 (3r 2000 6
SKETCH-02 (3rd LAYER)
SKETCH-02
Ld Ld

2000 DET 1 2000


2000

2000
DET 1 T32-150 (TOP)
WELDED COUPLER T32-150 (BOTTOM) WELDED COUPLER
MESH BOTHWAYS

bB PSR-1 PSR-1
SECTION : 1-1
1 : 20

bA
THE MEMBER SIZES AT THE INTERFACE TO BE COORDINATED AS PER
7 DET 2 STEEL PLATE AS PER SPECIALIST STEEL CONTRACTORS CONNECTION DESIGN. ACCORDINGLY 7
STEEL PLATE AS PER SPECIALIST CONTRACTOR.
SPECIALIST CONTRACTOR. CONSULTANT DRAWINGS WILL BE UPDATED ONCE THE CALCUALTIONS ARE
COMPLETED AND APPROVED BY SUPERVISION CONSULTANT AND REVISED
IFC WILL BE ISSUED FOR THE AREA INDICATED
TYPE EXTENTION SHEAR REINFORCEMENT REMARK

PSR1 3200 8L-T12-100 CLOSED STIRRUPS

SKETCH -01 PSR2 2000 4L-T16-150 CLOSED STIRRUPS

PSR3 1500 4L-T12-150 CLOSED STIRRUPS


REINF. AS PER PLAN
SLAB AS PER PLAN
PSR4 3000 8L-T10-100 CLOSED STIRRUPS
100

PSR5 1500 6L-T16-100 CLOSED STIRRUPS


8 8
Ld Ld OR 1.5 SPAN PSR6 1500 4L-T16-100 CLOSED STIRRUPS

COLUMN PSR7 2000 6L-T12-125 CLOSED STIRRUPS

ISSUE FOR CONSTRUCTION 15-02-2019 C2


ISSUE FOR CONSTRUCTION 07-03-2018 C1
SECTION : 2-2 FOR APPROVAL
ISSUED FOR INFORMATION
04-10-2017
27-09-2017
A6
A5
1 : 20 ISSUE FOR COORDINATION 05-07-2017 A4
FOR APPROVAL 24-04-2017 A3
FOR APPROVAL 16-03-2017 A2
ISSUE FOR CONSTRUCTION 27-12-2016 C0
FOR APPROVAL 11-12-2016 A1
TENDER ISSUE 29-09-2016 T1
DETAILED DESIGN 24-06-2016 P1
TENDER ISSUE 13-03-2016 T0

9 REVISIONS DATE REV NO. 9


ARCHITECT
PRINCIPAL ARCHITECT SM

ASSOCIATE ARCHITECT SM
10T40-150 10T40-150
STRUCTURAL DESIGN
APPROVED BY BS
CHECKED BY BA/MM
130MM THICK
. DRAWN BY AM/SK
BOTTOM PLATE FOR EQ REVIEWED BY AS
BOTTOM REINF.
CONNECTION PROJECT:
AS PER THE SPECIALIST STEEL CONTRACTOR DESIGN

10
One Za'abeel 10
2nd Zaa'beel Road
Dubai, UAE
P.O.Box 333888

00 CLIENT:
15
REINF. AS PER PLAN

STEEL PLATE/STIFFNER AS One Za’abeel LLC


PER THE SPECIALIST STEEL DIFC Gate Village Bldg.7, 6th floor
CONTRACTOR DESIGN. P.O.Box. 333888
Dubai, UAE

CONSULTANT/ARCHITECT OF RECORD:

11 11
. STEEL PLATE/STIFFNER AS PER THE
EQ SPECIALIST STEEL CONTRACTOR
DESIGN.

WSP Middle East Architectural & Engineering Consultancy


DETAIL-2 3D REBAR CONNECTION PLATE DETAIL PO Box 7497 Dubai, U.A.E
Tel: +971 4 350 5000 Fax: +971 4 350 5001
www.wsp.com
AS PER THE SPECIALIST STEEL CONTRACTOR DESIGN
TITLE:
PLOT B
LEVEL - 29 (DM PLAN 30F)
150 REINFORCEMENT PLAN SHEET 1
12 12
REINF. AS PER PLAN 3RD LAYER DIAGONAL REINF. STATUS:
ISSUE FOR CONSTRUCTION
DETAIL- 1 1 : 20 SCALE JOB NO. DWG NO. REV NO.

BOTTOM REBAR PLAN 1:100 37446660 TB-29F-S-01712 C2


DM DWG NO.
1 : 20
S-TB-29-01712