Alcatel-Lucent 9353
Wireless Management System
Node B Alarms Reference Guide for 9313/9314 Node B
Legal notice
Alcatel, Lucent, Alcatel-Lucent and the Alcatel-Lucent logo are trademarks of Alcatel-Lucent. All other
trademarks are the property of their respective owners.
The information presented is subject to change without notice. Alcatel-Lucent assumes no responsibility for
inaccuracies contained herein.
Copyright © 2004-2010 Alcatel-Lucent, All Rights Reserved
Contains proprietary/trade secret information which is the property of Alcatel-Lucent and must not be made
available to, or copied or used by anyone outside Alcatel-Lucent without its written authorization.
Not to be used or disclosed except in accordance with applicable agreements.
Alcatel-Lucent - Proprietary
Use pursuant to applicable agreements
Publication history 3
PUBLICATION HISTORY
SYSTEM RELEASE: V7.1
June 2010
Issue 07.05/EN Standard
Editorial update
May 2010
Issue 07.04/EN Standard
Up-Issue for DR5
November 2010
Issue 07.03/EN Preliminary
Update for DR4
November 2009
Issue 07.02/EN Preliminary
Update after review
September 2009
Issue 07.01/EN Draft
Update for V7.1 release
June 2009
Issue 06.02/EN Preliminary
Update after internal review
April 2009
Issue 06.01/EN Draft
Update for UA07.0 / OAM07.0 release
Copyright © 2004-2010 Alcatel-Lucent Node B Alarms Reference Guide for 9313/9314 Node B
Publication history 4
April 2009
Issue 05.12/EN Standard
Update for DR5
March 2009
Issue 05.11/EN Preliminary
Update after internal review
January 2009
Issue 05.10/EN Preliminary
Update after internal review
November 2008
Issue 05.09/EN Preliminary
Minor update
October 2008
Issue 05.08/EN Preliminary
Update for MNCL1
September 2008
Issue 05.07/EN Preliminary
Update after internal review
Additional updates per CR DCTPD00066045 completion
August 2008
Issue 05.06/EN Draft
Update for DR4
Resolution CR DCTPD00066045 Review comments to
NN-20500-018P3_Alcatel-Lucent_9300_WCDMA_
Product_Family_-_Node_B_Alarms_Reference_Guide_for_OneBTS_05.pdf
July 2008
Issue 05.05/EN Preliminary
Update after internal review
June 2008
Issue 05.04/EN Draft
Update for DR4
Copyright © 2004-2010 Alcatel-Lucent Node B Alarms Reference Guide for 9313/9314 Node B
Table of contents 6
Copyright © 2004-2010 Alcatel-Lucent Node B Alarms Reference Guide for 9313/9314 Node B
List of figures 8
Example 1 - 9313 Micro and 9314 Pico Node Bs designation.............................................................. ............. ......... 19
Copyright © 2004-2010 Alcatel-Lucent Node B Alarms Reference Guide for 9313/9314 Node B
10
Applicability
This publication applies Alcatel-Lucent W-CDMA V7.1 system release.
Audience
The publication is intended for operation and maintenance personnel and for those who want to know
the principles of the UMTS BTS 1120 and BTS 1010 alarm references.
Prerequisites
It is recommended that readers also become familiar with the following documents:
• Alcatel-Lucent 9313 Micro Node B Technical Description (NN-20500-053)
• Alcatel-Lucent 9314 Pico Node B Technical Description (NN-20500-094)
• Alcatel-Lucent 9300 W-CDMA Product Family - Fault Management (NN-20500-156)
• Alcatel-Lucent 9353 Management System - User Guide (NN-20500-032)
• UTRAN Supervision Guidelines (UMT/SYS/INF/007308)
Related documents
Alcatel-Lucent 9300 W-CDMA Product Family - Node B Alarms Reference Guide for Macro Node B
and Compact Node B (NN-20500-018)
9313 Micro and 9314 Pico Node Bs maintenance guides:
• Alcatel-Lucent 9313 Micro Node B Hardware Preventive Maintenance (NN-20500-054)
• Alcatel-Lucent 9313 Micro Node B Hardware Corrective Maintenance (NN-20500-055)
• Alcatel-Lucent 9313 Micro Node B and 9314 Pico Node B Operation and Maintenance Manual
(NN-20500-058)
• Alcatel-Lucent 9313 Micro Node B and 9314 Pico Node B Local Maintenance Tool Manual
(NN-20500-057)
This document describes the 9313 Micro and 9314 Pico alarms raised by the Node B equipment,
then the alarms raised by the OAM.
The corrective procedures applicable to the Node Bs refer to the Node B hardware maintenance
guides.
Vocabulary conventions
The glossary is presented in Alcatel-Lucent 9300 W-CDMA Product Family - Terminology
(NN-20500-002).
Safety regulations
To guarantee the safety of personnel and equipment, the following aspects must be taken into
account:
• general personnel safety instructions
• equipment safety instructions.
Copyright © 2004-2010 Alcatel-Lucent Node B Alarms Reference Guide for 9313/9314 Node B
12
Copyright © 2004-2010 Alcatel-Lucent Node B Alarms Reference Guide for 9313/9314 Node B
14
Features
N/A.
Other changes
For the list of removed, new and modified Node B alarms in this release, see Alcatel-Lucent 9300
W-CDMA Product Family - UA07.1 / OAM07.1 Release Operational Impacts: CM, FM and PM Delta
(NN-20500-052).
Introduction
This publication contains the alarm descriptions and refers to corrective maintenance procedures
applicable to the Node B. See the list of Node B hardware maintenance guides in the Related
documents section.
This document does not list alarms generated by LMT, for description of these alarms, see
Alcatel-Lucent Micro Node B and 9314 Pico Node B Local Maintenance Tool Manual
(NN-20500-057).
The general principles and messages required for Node B maintenance are described in 9353
Management System - User Guide (NN-20500-032).
Network maintenance is based on graphical supervision of the network. It is also based on the
identification and replacement of faulty items of equipment, using the alarms.
Copyright © 2004-2010 Alcatel-Lucent Node B Alarms Reference Guide for 9313/9314 Node B
16
An alarm sheet contains a description providing the short explanation of the alarm and a table
detailing the following information:
Copyright © 2004-2010 Alcatel-Lucent Node B Alarms Reference Guide for 9313/9314 Node B
18
Severity
The Node B uses the following perceived severity:
• CRITICAL: indicates that a service affecting condition has occurred and an immediate corrective
action is required.
• MAJOR: indicates that a service affecting condition has developed and an urgent corrective
action is required.
• minor: indicates the existence of a non-service affecting fault condition and that corrective action
will have to be taken in order to prevent a more serious fault.
• warning: indicates the detection of a potential or impending service-affecting fault, before any
significant effects have been felt.
Copyright © 2004-2010 Alcatel-Lucent Node B Alarms Reference Guide for 9313/9314 Node B
20
Copyright © 2004-2010 Alcatel-Lucent Node B Alarms Reference Guide for 9313/9314 Node B
22
F5 AIS ERROR
Alarm Code MicroBTS_1040_00050
Object Class MicroBTS/ALCAP
Equipment Type ALCAP
Event Type communicationsAlarm
Probable Cause remoteNodeTransmissionError
Severity
• MAJOR
Impact Possible capacity or performance degradation.
Reason A neighboring node has signaled to the BTS an upstream connectivity
failure.
Remedial Action Check the transmission links. Check the configuration of the BTS
1120/BTS 1010, RNC, and transmission network with respect to the af-
fected PVC. When the fault is repaired the alarm will be ceased auto-
matically by BTS 1120/BTS 1010.
F5 RDI ERROR
Alarm Code MicroBTS_1041_00050
Object Class MicroBTS/ALCAP
Equipment Type ALCAP
Event Type communicationsAlarm
Probable Cause remoteNodeTransmissionError
Severity
• MAJOR
Impact Possible capacity or performance degradation.
Reason A neighboring node has signaled to the BTS an upstream connectivity
failure.
Remedial Action Check the transmission links. Check the configuration of the BTS
1120/BTS 1010, RNC and transmission network with respect to the af-
fected PVC. When the fault is repaired the alarm will be ceased auto-
matically by BTS 1120/BTS 1010.
Copyright © 2004-2010 Alcatel-Lucent Node B Alarms Reference Guide for 9313/9314 Node B
24
Copyright © 2004-2010 Alcatel-Lucent Node B Alarms Reference Guide for 9313/9314 Node B
26
VSWR FAULT
Alarm Code MicroBTS_1029_00130
Object Class MicroBTS/SectorEquipment/AntennaAccess
Equipment Type AntennaAccess
Event Type equipmentAlarm
Probable Cause equipmentMalfunction
Severity
• MAJOR
• warning
Impact Possible capacity and/or performance degradation.
Reason Reflected power too high.
Remedial Action The BTS 1120 (Micro) will automatically cease of alarm if the VSWR
fault indication disappears. The operators can restart the BTS 1120
(Micro) to check if the alarm persists. If the alarm persists the antenna
may be defect, or there may be a loose (RF) connection between an-
tenna and the sector equipment unit. The antenna cables should also
be inspected for possible damages or problems.
Copyright © 2004-2010 Alcatel-Lucent Node B Alarms Reference Guide for 9313/9314 Node B
28
Copyright © 2004-2010 Alcatel-Lucent Node B Alarms Reference Guide for 9313/9314 Node B
30
F5 AIS ERROR
Alarm Code MicroBTS_1040_00060
Object Class MicroBTS/CCP
Equipment Type CCP
Event Type communicationsAlarm
Probable Cause remoteNodeTransmissionError
Severity
• MAJOR
Impact Possible capacity or performance degradation.
Reason A neighboring node has signaled to the BTS an upstream connectivity
failure.
Remedial Action Check the transmission links. Check the configuration of the BTS
1120/BTS 1010, RNC, and transmission network with respect to the af-
fected PVC. When the fault is repaired the alarm will be ceased auto-
matically by BTS 1120/BTS 1010.
Copyright © 2004-2010 Alcatel-Lucent Node B Alarms Reference Guide for 9313/9314 Node B
32
F5 RDI ERROR
Alarm Code MicroBTS_1041_00060
Object Class MicroBTS/CCP
Equipment Type CCP
Event Type communicationsAlarm
Probable Cause remoteNodeTransmissionError
Severity
• MAJOR
Impact Possible capacity or performance degradation.
Reason A neighboring node has signaled to the BTS an upstream connectivity
failure.
Remedial Action Check the transmission links. Check the configuration of the BTS
1120/BTS 1010, RNC and transmission network with respect to the af-
fected PVC. When the fault is repaired the alarm will be ceased auto-
matically by BTS 1120/BTS 1010.
Copyright © 2004-2010 Alcatel-Lucent Node B Alarms Reference Guide for 9313/9314 Node B
34
Copyright © 2004-2010 Alcatel-Lucent Node B Alarms Reference Guide for 9313/9314 Node B
36
Copyright © 2004-2010 Alcatel-Lucent Node B Alarms Reference Guide for 9313/9314 Node B
38
Copyright © 2004-2010 Alcatel-Lucent Node B Alarms Reference Guide for 9313/9314 Node B
40
Copyright © 2004-2010 Alcatel-Lucent Node B Alarms Reference Guide for 9313/9314 Node B
42
F5 AIS ERROR
Alarm Code MicroBTS_1040_00020
Object Class MicroBTS/ItfB
Equipment Type ItfB
Event Type communicationsAlarm
Probable Cause remoteNodeTransmissionError
Severity
• MAJOR
Impact Possible capacity or performance degradation.
Reason A neighboring node has signaled to the BTS an upstream connectivity
failure. A neighboring node has signaled to the BTS an upstream con-
nectivity failure.
Remedial Action Check the transmission links. Check the configuration of the BTS
1120/BTS 1010, RNC, and transmission network with respect to the af-
fected PVC. When the fault is repaired the alarm will be ceased auto-
matically by BTS 1120/BTS 1010.
F5 RDI ERROR
Alarm Code MicroBTS_1041_00020
Object Class MicroBTS/ItfB
Equipment Type ItfB
Event Type communicationsAlarm
Probable Cause remoteNodeTransmissionError
Severity
• MAJOR
Impact Possible capacity or performance degradation.
Reason A neighboring node has signaled to the BTS an upstream connectivity
failure.
Remedial Action Check the transmission links. Check the configuration of the BTS
1120/BTS 1010, RNC and transmission network with respect to the af-
fected PVC. When the fault is repaired the alarm will be ceased auto-
matically by BTS 1120/BTS 1010.
Copyright © 2004-2010 Alcatel-Lucent Node B Alarms Reference Guide for 9313/9314 Node B
44
Copyright © 2004-2010 Alcatel-Lucent Node B Alarms Reference Guide for 9313/9314 Node B
46
INACCURATE RF REFERENCE
Alarm Code MicroBTS_1006_00000
Object Class MicroBTS
Equipment Type MicroBTS
Event Type processingErrorAlarm
Probable Cause timingProblem
Severity
• MAJOR
Impact All traffic services are shut down.
Reason The RF Reference is outside 3GPP requirements.
Remedial Action Inspect the status of the physical links. The physical link status view
can be read using the Local Management Tool. The fault ceases auto-
matically when the BTS 1120/BTS 1010 is able to obtain synchroniza-
tion from one of its physical links. The fault ceases automatically when
the required RF stability is reached. For example, after the timing refer-
ence has recovered, that is, when the RF reference is within 3GPP
specification. Note that it can take some time for the PLL to stabilize. If
the alarm persists even though synchronization can be obtained via
the physical links, the reason can be an hardware fault in BTS
1120/BTS 1010 and the unit needs to be replaced. Always attempt a
restart first though.
Copyright © 2004-2010 Alcatel-Lucent Node B Alarms Reference Guide for 9313/9314 Node B
48
LMT CONNECTED
Alarm Code MicroBTS_1007_00000
Object Class MicroBTS
Equipment Type MicroBTS
Event Type operatorAlarm
Probable Cause unspecifiedReason
Severity
• warning
Impact None
Reason The Local Management Tool has been connected.
Remedial Action The alarm ceases when the LMT Ethernet contact is disconnected. If
the alarm is activated but no management via the LMT is expected,
somebody can be attempting an unauthorized access to the BTS
1120/BTS 1010.
Copyright © 2004-2010 Alcatel-Lucent Node B Alarms Reference Guide for 9313/9314 Node B
50
Copyright © 2004-2010 Alcatel-Lucent Node B Alarms Reference Guide for 9313/9314 Node B
52
Copyright © 2004-2010 Alcatel-Lucent Node B Alarms Reference Guide for 9313/9314 Node B
54
Copyright © 2004-2010 Alcatel-Lucent Node B Alarms Reference Guide for 9313/9314 Node B
56
F5 AIS ERROR
Alarm Code MicroBTS_1040_00030
Object Class MicroBTS/NodeBCP
Equipment Type NodeBCP
Event Type communicationsAlarm
Probable Cause remoteNodeTransmissionError
Severity
• MAJOR
Impact Possible capacity or performance degradation.
Reason A neighboring node has signaled to the BTS an upstream connectivity
failure.
Remedial Action Check the transmission links. Check the configuration of the BTS
1120/BTS 1010, RNC, and transmission network with respect to the af-
fected PVC. When the fault is repaired the alarm will be ceased auto-
matically by BTS 1120/BTS 1010.
F5 RDI ERROR
Alarm Code MicroBTS_1041_00030
Object Class MicroBTS/NodeBCP
Equipment Type NodeBCP
Event Type communicationsAlarm
Probable Cause remoteNodeTransmissionError
Severity
• MAJOR
Impact Possible capacity or performance degradation.
Reason A neighboring node has signaled to the BTS an upstream connectivity
failure.
Remedial Action Check the transmission links. Check the configuration of the BTS
1120/BTS 1010, RNC and transmission network with respect to the af-
fected PVC. When the fault is repaired the alarm will be ceased auto-
matically by BTS 1120/BTS 1010.
Copyright © 2004-2010 Alcatel-Lucent Node B Alarms Reference Guide for 9313/9314 Node B
58
Copyright © 2004-2010 Alcatel-Lucent Node B Alarms Reference Guide for 9313/9314 Node B
60
Copyright © 2004-2010 Alcatel-Lucent Node B Alarms Reference Guide for 9313/9314 Node B
62
Copyright © 2004-2010 Alcatel-Lucent Node B Alarms Reference Guide for 9313/9314 Node B
64
BATTERY MALFUNCTION
Alarm Code MicroBTS_1027_00160
Object Class MicroBTS/SectorEquipment/PowerSystem
Equipment Type PowerSystem
Event Type equipmentAlarm
Probable Cause powerProblem
Severity
• MAJOR
• minor
Impact None - as long as there is no problem with the incoming power.
Reason The internal backup battery is faulty.
Remedial Action Minor: Replace the battery within sector equipment unit within reason-
able time. The battery is close to its end of life. Major: The battery has
passed its end of life and need to be replaced immediately.
BATTERY DISCHARGED
Alarm Code MicroBTS_1028_00160
Object Class MicroBTS/SectorEquipment/PowerSystem
Equipment Type PowerSystem
Event Type equipmentAlarm
Probable Cause powerProblem
Severity
• MAJOR
Impact None - as long as there is no problem with the incoming power.
Reason The internal backup battery is discharged.
Remedial Action This is a normal alarm after a longer interrupt in the incoming power,
during which the BTS 1120 (Micro) has been running on the backup
battery. If the alarm persists for more than 24 h the battery needs to be
replaced.
Copyright © 2004-2010 Alcatel-Lucent Node B Alarms Reference Guide for 9313/9314 Node B
66
Copyright © 2004-2010 Alcatel-Lucent Node B Alarms Reference Guide for 9313/9314 Node B
68
Copyright © 2004-2010 Alcatel-Lucent Node B Alarms Reference Guide for 9313/9314 Node B
70
LICENSE ERROR
Alarm Code MicroBTS_1036_00010
Object Class MicroBTS/SectorEquipment
Equipment Type SectorEquipment
Event Type processingErrorAlarm
Probable Cause configurationOrCustomizationError
Severity
• minor
Impact N/A
Reason License Upgrade function has failed.
Remedial Action Check the license server.
Copyright © 2004-2010 Alcatel-Lucent Node B Alarms Reference Guide for 9313/9314 Node B
72
LICENSE EXPIRED
Alarm Code MicroBTS_1037_00010
Object Class MicroBTS/SectorEquipment
Equipment Type SectorEquipment
Event Type equipmentAlarm
Probable Cause configurationOrCustomizationError
Severity
• minor
Impact N/A
Reason The license has expired.
Remedial Action Update the license.
Copyright © 2004-2010 Alcatel-Lucent Node B Alarms Reference Guide for 9313/9314 Node B
74
Copyright © 2004-2010 Alcatel-Lucent Node B Alarms Reference Guide for 9313/9314 Node B
76
F5 AIS ERROR
Alarm Code MicroBTS_1040_00070
Object Class MicroBTS/UserDataPort
Equipment Type UserDataPort
Event Type communicationsAlarm
Probable Cause remoteNodeTransmissionError
Severity
• MAJOR
Impact Possible capacity or performance degradation.
Reason A neighboring node has signaled to the BTS an upstream connectivity
failure. A neighboring node has signaled to the BTS an upstream con-
nectivity failure.
Remedial Action Check the transmission links. Check the configuration of the BTS
1120/BTS 1010, RNC, and transmission network with respect to the af-
fected PVC. When the fault is repaired the alarm will be ceased auto-
matically by BTS 1120/BTS 1010.
F5 RDI ERROR
Alarm Code MicroBTS_1041_00070
Object Class MicroBTS/UserDataPort
Equipment Type UserDataPort
Event Type communicationsAlarm
Probable Cause remoteNodeTransmissionError
Severity
• MAJOR
Impact Possible capacity or performance degradation.
Reason A neighboring node has signaled to the BTS an upstream connectivity
failure.
Remedial Action Check the transmission links. Check the configuration of the BTS
1120/BTS 1010, RNC and transmission network with respect to the af-
fected PVC. When the fault is repaired the alarm will be ceased auto-
matically by BTS 1120/BTS 1010.
Copyright © 2004-2010 Alcatel-Lucent Node B Alarms Reference Guide for 9313/9314 Node B
78
Copyright © 2004-2010 Alcatel-Lucent Node B Alarms Reference Guide for 9313/9314 Node B
80
Loss of supervision
Alarm Code OAM_0097_00058
RAN Managed Ob- MicroBTS
ject
Equipment Type N/A
Event Type communications
Probable Cause communicationsSubsystemFailure
Severity CRITICAL
Impact The state of MicroBTS is unknown due to loss of OAM link.
Reason Loss of OAM link between OMC and MicroBTS.
Remedial Action cf iBTS Hardware maintenance Guide - No particular action is re-
quired. This notification may be required by Global Product Support for
debugging purposes
Copyright © 2004-2010 Alcatel-Lucent Node B Alarms Reference Guide for 9313/9314 Node B
82
BTS RESTART
Alarm Code OAM_0099_00058
RAN Managed Ob- MicroBTS
ject
Equipment Type N/A
Event Type processing error
Probable Cause softwareProgramError
Severity warning
Impact N/A
Reason This event indicates a restart of the micro/pico BTS.
Remedial Action N/A
Copyright © 2004-2010 Alcatel-Lucent Node B Alarms Reference Guide for 9313/9314 Node B
84
Copyright © 2004-2010 Alcatel-Lucent Node B Alarms Reference Guide for 9313/9314 Node B
Alcatel-Lucent 9353
Wireless Management System
Alcatel-Lucent
Node B Alarms Reference Guide for 9313/9314 Node B
Legal notice
Alcatel, Lucent, Alcatel-Lucent and the Alcatel-Lucent logo are trademarks of Alcatel-Lucent. All other trademarks are the property of
their respective owners.
The information presented is subject to change without notice. Alcatel-Lucent assumes no responsibility for inaccuracies contained
herein.
Contains proprietary/trade secret information which is the property of Alcatel-Lucent and must not be made available to, or copied or
used by anyone outside Alcatel-Lucent without its written authorization.
Alcatel-Lucent - Proprietary
Use pursuant to applicable agreements