(List of Experiments)
Weeks Experiments
Week 1 Introduction to IPC Lab and lab safety Introduction to IPC Lab and lab safety
Week 2 Calibration of thermocouple and flow Sensor Calibration of level sensor and Pressure
Sensor
Week 3 Calibration of level sensor and Pressure Sensor Calibration of thermocouple and flow Sensor
Week 4 Controlling Flow of fluid manually on Flow Controlling temperature manually on
control unit. temperature controls Unit.
Controlling temperature using on/off loop on
temperature controls Unit.
Week 5 Controlling temperature manually on Tuesday 19-2-19 IPC Engr iqra was on leave
temperature controls Unit. due to death of her father, Dr. Erum took the
Lecture of Class
Friday-L1 Lab was conducted by Engr Zarrar
directed by Dr. Zaib
Controlling level manually on level controls
Unit.
Controlling level using on/off loop on level
controls Unit.
Week 6 Controlling the Flow in Closed loop Controlling Flow of fluid manually on Flow
control unit.
Week 7 Controlling Pressure Manually on pressures Industrial visit ICI on Tuesday 05 Feb 19
control Unit. Friday: only group took lab instead of ___ to
balance the lab (Controlling level manually on
level controls Unit.
Controlling level using on/off loop on level
controls Unit.)
Week 8 Controlling Level manually on Level Control Controlling the Flow in Closed loop
Unit
Week 9 Mid Viva Mid Viva
Week 10 Level Control loops (Proportional + Integral) Flow control loops (Proportional)
Week 11 Flow control loops (Proportional + Integral + Flow control loops (Proportional + Integral)
Derivative)
Week 12 Temperature Control loops (Proportional + Level Control loops (proportional)
Integral)
Week 13 Characteristics of Proportional Controller(P)
and Proportional and integral
Controller(P+I)
Week 14 Characteristics of Proportional and Derivative
Controller(P+D)
Week 15 Final Viva
1. For a flow rate control system or temperature control system , specify values
of set point, controlled variable, manipulated variable, disturbance and sensitivity.
2. Use Proportional, PI and PD and PID control mechanism to reject the effect of
the disturbance
3. Compare results of the control mechanism and submit it in the form of a report.