W-FAZ/A4 W-FAZ/HCR FIXING ANCHORS

02.6

Individual attachment:
Cracked and uncracked concrete

W-FAZ/A4,
Stainless steel A4

W-FAZ/HCR
(via special order)
Highly corrosion-resistant steel
(1.4529)

For W-FAZ/S Fixing Anchor, see 02.5

Proof of performance

Approvals Test reports 2. Advantages


• High loads, small axle bases and edge Machine Setting Tool for
European clearances
Technical Fire resistance M8 - M24 • Time-saving through-bolt mounting fixing anchors (W-FA &
Fire resistance • Can be loaded immediately – no
Approval Technical Report W-FAZ) M8 – M16
TR 020 Direct flame ēect waiting times
Option 1 for cracked R30 - R120 • The fixed anchor cone with
and uncracked concrete patented plastic coating
facilitates reliable later
expansion
• Reliable mounting thanks to the
application of the prescribed torque Art. No. 0904 908 016
when anchoring
For details, see separate product
3. Properties information
1. Applications • Force-controlled/torque-controlled
• Can be used for medium to heavy loads spreading anchor made of stainless steel A4 and highly corrosion-resistant steel HCR in the
• Suitable for fastening: Metal structures, metal profiles, brackets, foot plates, supports, sizes M8, M10, M12, M16 and M20
cable conduits, piping, railings, wooden structures, beams etc. • Approvals:
• With European Technical Approval, the anchor may be used in reinforced or unreinforced ETA-99/0011 for individual attachment
standard concrete of a strength class of at least C20/25 and at most C50/60 in Option 1, cracked and uncracked concrete, stainless steel A4 and HCR highly corrosion-
accordance with EN 206:2000-12 resistant steel; dimensioned in accordance with the "Guideline for European Technical
• For use in concrete < C20/25 and pressure-resistant natural stone (without approval) Approval (ETAG) of Metal Anchors for Use in Concrete", Appendix C, Measurement
• The anchor may be used for anchoring under primarily static loads or quasi-static loads Process A
• Individual fastening: Anchoring with European Technical Approval in cracked • Fire resistance: W-FAZ/A4, W-FAZ/HCR (M8 – M16) R30, R60, R90, R120
concrete (concrete tensile zone) and in uncracked concrete (concrete pressure Technical Report TR020 (contained in ETA-99/0011)
zone) Fire resistance: W-FAZ/A4, W-FAZ/HCR (M8 – M16) F30, F60, F90 and F120
• W-FAZ/A4 (stainless steel A4) may be used in dry indoor rooms, outdoors Fire load according to DIN 4102-02:1977-09
(including industrial atmospheres and near the sea) or in humid rooms if no especially (ETK – Einheits-Temperaturzeitkurve (standard temperature time curve))
aggressive conditions exist Fire resistance: W-FAZ/HCR (M8 – M16) Fire load according to the ZTV tunnel fire
• W-FAZ/HCR (highly corrosion-resistant steel HCR) may be used in areas with a compartment curve
very high corrosion potential e.g. indoor pool atmosphere, road tunnels, poorly
ventilated parking garages and parts in seawater and in a marine atmosphere).

Setting instructions
MWF - 05/12 - 04381 - ©

Drill hole Clean drilled hole Knock in anchor Mount component Apply torque
with mason's mallet
or machine setting
tool
W-FAZ/A4 W-FAZ/HCR FIXING ANCHORS
02.6

Performance data
Anchor diameter [in mm] M8 M10 M12 M16 M20
Perm. Tensile zone
centered (cracked concrete C20/252), s • 2.4 4.3 7.6 11.9 17.1
tensile load1) 3 hef, c • 1.5 hef)
N perm. [kN] = C20/252)
on a single anchor Pressure zone
without edge (uncracked concrete 5.7 7.6 11.9 16.7 24.0
influence C20/252),scr,sp and ccr,sp see approval
Perm. Tensile zone
transverse (uncracked concrete C20/252), 7.4 11.4 17.1 26.9 34.3
load1) c • 10 hef)
on a single Vperm. [kN] = C20/25
2)
Pressure zone
anchorwithout (uncracked concrete C20/252), 7.4 11.4 17.1 31.4 43.9
edge influence c • 10 hef)
Permissible bending torque M perm [Nm] 14.9 29.7 52.6 133.1 231.6
Permissible load under fire load (R30, R60, R90, R120) see European Technical Approval ETA-99/0011
F30 [in kN] 9.0 15.0 19.0 30.0 –
Fire resistance duration F60 [in kN] 5.0 9.0 12.0 15.0 –
(anchoring base: concrete • C20/25) F90 [in kN] 1.8 4.0 5.0 7.5 –
F120 [in kN] 1.0 2.0 3.0 6.0 –

Characteristic values
Standard minimum component thickness h std• [in mm] 100 120 140 160 200
Minimum axial spacing smin• [in mm] 40 40 50 50 60 60 60 65 95 90
Cracked concrete Uncracked concrete for c • [in mm] 70 80 75 75 100 120 100 120 150 180
Minimum edge spacing c min• [in mm] 40 50 55 60 60 75 60 80 95 130
Cracked concrete Uncracked concrete for s • [in mm] 80 100 90 120 140 150 180 150 200 240
Reduced minimum component thickness h min• [in mm] 80 100 120 140 –
Minimum axial spacing smin• [in mm] 40 40 45 60 60 60 70 80 – –
Cracked concrete Uncracked concrete for c • [in mm] 70 80 90 140 100 120 160 180 – –
Minimum edge spacing c min• [in mm] 40 50 50 90 60 75 80 90 – –
Cracked concrete Uncracked concrete for s • [in mm] 80 100 115 140 140 150 180 200 – –
Axial spacing scr,N [in mm] 138 180 210 255 300
Edge spacing ccr,N [in mm] 69 90 105 127.5 150
Effective anchoring depth hef [in mm] 46 60 70 85 100
Nom. drill dia. d 0 [in mm] 8 10 12 16 20
Drill cutting dia. dcut” [in mm] 8.45 10.45 12.5 16.5 20.55
Drill hole depth h1• [in mm] 60 75 90 110 125
Through-hole in the component being connected d f” [in mm] 9 12 14 18 22
Torque while installing anchor Tinst = [in Nm] 20 35 50 110 200

Anchor dimensions (W-FAZ/HCR available via special order)


W-FAZ/A4 M8 M10 M12 M16 M20
75
80
95
115
165
90
95
110
130
180
110
115
125
145
180
220
255
275
300
325
145
170
220
280
300
325
340
165
195
265
Total length l [in mm] 285
10
15
30
50
100
10
15
30
50
100
15
20
30
50
85
125
160
180
205
230
25
50
100
160
180
205
220
30
60
130
150

Max. attachment height t fix [in mm]


W-FAZ/A4 M10-100/180

W-FAZ/A4 M12-125/220
W-FAZ/A4 M12-160/255
W-FAZ/A4 M12-180/275
W-FAZ/A4 M12-205/300
W-FAZ/A4 M12-230/325

W-FAZ/A4 M16-100/220
W-FAZ/A4 M16-160/280
W-FAZ/A4 M16-180/300
W-FAZ/A4 M16-205/325
W-FAZ/A4 M16-220/340

W-FAZ/A4 M20-130/265
W-FAZ/A4 M20-150/285
W-FAZ/A4 M8-100/165

W-FAZ/A4 M10-30/110
W-FAZ/A4 M10-50/130

W-FAZ/A4 M12-15/110
W-FAZ/A4 M12-20/115
W-FAZ/A4 M12-30/125
W-FAZ/A4 M12-50/145
W-FAZ/A4 M12-85/180

W-FAZ/A4 M16-25/145
W-FAZ/A4 M16-50/170

W-FAZ/A4 M20-30/165
W-FAZ/A4 M20-60/195
W-FAZ/A4 M8-50/115

W-FAZ/A4 M10-10/90
W-FAZ/A4 M10-15/95
W-FAZ/A4 M8-10/75
W-FAZ/A4 M8-15/80
W-FAZ/A4 M8-30/95

Designation
0904 608 100

0904 610 100


0904 621 201
0904 621 202
0904 621 203
0904 621 204
0904 621 205
0904 621 206
0904 621 207
0904 621 208
0904 621 210
0904 621 211

0904 616 100


0904 616 160
0904 616 180
0904 616 205
0904 616 220

0904 620 130


0904 620 150
0904 608 10
0904 608 15
0904 608 30
0904 608 50

0904 610 10
0904 610 15
0904 610 30
0904 610 50

0904 616 25
0904 616 50

0904 620 30
0904 620 60

W-FAZ/A4 Fixing Anchor Art. No.


Stainless steel A4
100
100
100
100
50
50
50
50
50
50
25
25
25
25
25
25
20
20
20
20
20
20
10
10
10
10
10
10
10
5
5

Packing unit P. Qty.


MWF - 06/11 - 04382 - ©

Würth system components

1) The part-safety coe̅cients of the resistances regulated in the approval and a part-safety coe̅cient ofthe ē ects
of γF = 1.4 have been taken into account. For the combination of tensile and transverse loads, for edge influence
and anchor groups, please refer to the Guideline for European Technical Approval (ETAG), Appendix C.
2) The concrete has normal reinforcement. Higher values are possible for higher concrete strengths.