The FOA Reference For Fiber Optics http://www.thefoa.org/tech/ref/testing/accuracy/accuracy.

html

Topic: Accurately Testing Fiber Table of Contents:


The FOA Reference Guide To
Optic Cables Fiber Optics

Accurately Testing Fiber Optic Cables

Note: You need to know what we mean when we say “accurate” – that the
measurement made gives a value close to the “real” value. Another term often
misunderstood is "precision" which means if you make the same measurement over
and over, you get the same value, but that value may not be accurate. Standards
people prefer to talk about the “uncertainty” of the measurement because it’s
practically impossible to know what the real value is, but it is possible to determine how
much error is likely in any given measurement. With apologies to those people, I’m
going to use the term accuracy because everyone uses it more commonly.

The customer for a fiber optic cable installation will require documentation of test
results before accepting and paying for the work. This obviously leads to certain but
often conflicting requirements on the part of the contractor doing the installation.
Testing takes time, so completing all the tests in the minimum time means more profit.
Testing, however, needs to be done carefully to ensure the measurements are
accurate1, and that can take time. Accurate testing, however, will ensure that no good
cables are rejected and no bad ones missed, so the contractor will not have to repair
what are really good cables and get callbacks on bad ones.

Lots of time – and cost - can be saved if the contractor and installers know the
proper measurements that need to be made, understands how to make those
measurements correctly, has the proper tools, keeps them in good condition, has them
calibrated regularly and knows how to use them efficiently. It is also the duty of the
contractor to convey to the customer what is being done is in line with industry
convention and standards. Learning the background and the issues concerned with
making accurate measurements can save lots of problems – and money.

Industry committees spend massive amounts of time and energy developing


standards that ensure accurate testing. However, those standards are generally written
for manufacturers, not users, so the task of translating “standardese” – the language
they are written in – into understandable English is left to the manufacturers
themselves and technical educators in articles like this. This tutorial will give you

1 of 11 01/05/2016 3:23 PM
The FOA Reference For Fiber Optics http://www.thefoa.org/tech/ref/testing/accuracy/accuracy.html

insight into what tests are required, what problems are inherent in testing multimode
fiber, how measurement techniques differ and how to interpret the results of testing
and document them.

What Tests Are Available, Needed and Performed?

All fibers in a cable plant should be tested at least for continuity, proper end to end
connections and, most importantly, loss. How each of these tests are performed
depends on the installation type, required standards and the actual layout of the
components in the cable plant.

Actually, there are five industry standard ways of testing the loss of a fiber optic
cable – three for insertion loss and two for OTDRs – depending on how you use
reference test cables for your setup. Insertion loss testing with a test source and power
meter with reference cables (right) can use 1, 2 or 3 reference cables to set the “zero
dB loss” reference for testing and each way gives a different loss. Generally standards
prefer the 1 reference cable loss method, but it requires that the test equipment uses
the same fiber optic connector types as the cables under test. If the cable has different
connectors than the test equipment (e.g. LCs on the cable and SCs on the tester), it
may be necessary to use a 2 or 3 cable reference, which will give a lower loss since
connector loss is included in the reference and will be subtracted from the total loss
measurement. Any of the three methods are acceptable, as long as the method is
documented. Be careful, however, as most network link losses assume a 1 cable
reference, which can affect the acceptance of the cable.

OTDRs (Figure 2) always require a launch cable for the instrument to settle down
after reflections from the high powered test pulse overloads the instrument. OTDRs
have traditionally been used with long distance networks where only a launch cable is
used, but this method does not measure the loss of the connector on the far end.
Adding a cable at the far end allows measuring the loss of the entire cable, but
negates the big advantage of the OTDR, that it makes measurements from only one
end of the cable.

2 of 11 01/05/2016 3:23 PM
The FOA Reference For Fiber Optics http://www.thefoa.org/tech/ref/testing/accuracy/accuracy.html

First of all, to look at test requirements, we'll divide the topic by installation type:
Outside Plant (OSP) or Premises.

Testing Outside Plant Cables

OSP cables are typically long distance singlemode cables that are installed in short
sections, usually 5-12 km max depending on the cable size, since the bulk and weight
of the cable determines how long is the longest cable that can be installed. Shorter
lengths may be common in urban or campus networks, as cable is installed between
junction points which are determined by the geography of the cable plant. Since
shorter lengths of cable are spliced together, verification of the splices is important and
is usually done with an OTDR test during the installation process. Once installation is
complete, end-to-end insertion loss is done with a test source and optical power meter,
sometimes called an OLTS (optical loss test set) and reference test cables. Certain
ultra-long distance cables may require more complex testing for chromatic or
polarization-mode dispersion.

The accuracy of testing these long singlemode fibers with multiple splices depends
on many factors. Since the fibers are long, the attenuation of the fiber is an important
part of the measured loss. Since the attenuation coefficient of the fiber is dependent on
the wavelength of the light source, small differences in the wavelength of a test source
(in either an OLTS or OTDR) can lead to significant differences in the measured loss.
The only way to minimize this variation is to use test sources as close to the nominal
wavelengths as possible (1310 and 1550 nm typically, althoght others may be
specified.)

OTDRs depend on fiber backscatter for making measurements, so any difference in


fiber backscatter at a splice will lead to higher loss in one direction and lower loss (or a
gain) in the other direction. The only way to accurately measure splice loss is to
measure in both directions and average, a tedious process in a long, large fiber count
cable. One can get an idea of the magnitude of the uncertainty of the measurement by
looking at the attenuation coefficient of the fiber on either side of the splice. It the two
fibers are nearly equal, the directional variation will be small, but if they are large, big
differences may be found.

How Do You Test Premises Cables?

In premises cabling systems designed for use with LAN backbones, fiber to the
desk, CCTV, industrial control signals, etc., there are three tests that may be done,
connection verification, insertion loss and OTDR. All cables should be tested for
continuity with a visual fault locator or fiber tracer and the connections verified. In my
experience, many fiber optic cabling problems are caused by poor documentation or
confirmation of connections. Since each link consists of two fibers, one fiber must
connect a transmitter to a receiver and the other the complementary pair.
Documentation and markings should all these connections to be made simply. This is
easily confirmed with a visual light source coupled into the fiber.

The measurement needed for confirming the quality of the installation is the optical
loss or insertion loss of each of the fibers in the cable. Loss measurements are made
end-to-end on the permanently installed cable plant, the equivalent of the UTP
permanent link. Industry standards call for making that measurement with a test source

3 of 11 01/05/2016 3:23 PM
The FOA Reference For Fiber Optics http://www.thefoa.org/tech/ref/testing/accuracy/accuracy.html

and optical power meter, sometimes called an OLTS (optical loss test set) and
reference test cables.

Proposals have been made to also allow testing installed cable with just an optical
time domain reflectometer (OTDR) but no accepted standard today requires this.
TIA-568 (both the B version and the soon to be published C version) follows the
industry convention, requiring insertion loss testing (called Tier 1 testing in TIA-568)
and permits OTDR testing also (Tier 2) to provide additional information, but does not
allow OTDR only testing in lieu of insertion loss testing.

The use of OTDR testing of premises cable plants instead of insertion loss testing
causes much confusion among contractors and customers. Hardly a week goes by that
the FOA does not get a call regarding this issue. Misinterpretation of these
requirements have led to some unhappy instances in our experience, including
misreading OTDRs causing the removal and discarding of $100,000 worth of good
cable and the retesting of 1100 cables of 12 fibers each, as well as several instances
of customers returning OTDRs to distributors who sold them the units.

Measurement Uncertainty

Two Types of Measurement Errors

Measuring a physical parameter always involves errors. Unfortunately you never


know the real value you are trying to measure to begin with, so all you can do is to
estimate the error based on the possible sources of error in making the measurement.
There are two types of errors, random and systematic.

Random errors are what you see when you make a measurement multiple times
and get a slightly different value each time. Hook up your instrument and make the
measurement, disconnect and try again. Each time, the result will be slightly different.
Generally one should make several measurements, average them and use the data to
calculate the random error, called standard deviation, to understand the uncertainty of
the measurement. Random errors define precision.

Systematic errors are how the average measurement differs from the real value,
which can be caused by some problem in setup or calibration. Unfortunately, it’s hard
to determine the systematic error, but some possible ways exist sometimes. We'll look
at systematic errors first. Systematic errors are related to what we call accuracy.

Systematic Errors in Fiber Optic Measurements

Why would all measurements be slightly different from the "real" value. Consider
testing long lengths of singlemode fibers. The attenuation coefficient of the fiber is
measured by the manufacturer at 1310 nm, but your test source may have a
wavelength slightly different. If your source wavelength is shorter than 1310 (say 1290
nm, still within the limits of wavelength standards for laser sources,) all measurements
of loss will be slightly higher than the manufacturer's tests. It may only be 0.02-0.03
dB/km, but over 25 km, that makes a difference of 0.5-0.75 dB loss. Likewise a test
source at longer wavelength (say 1330 nm) will measure lower loss.

In multimode fiber, LED test sources, which have wide spectral output, may have not
only a different wavelength, but different spectral outputs. The measured loss will be
an integration of all the wavelengths. Different LEDs will measure different losses, but
the effect may not be large because most measurements are made on short cables. A

4 of 11 01/05/2016 3:23 PM
The FOA Reference For Fiber Optics http://www.thefoa.org/tech/ref/testing/accuracy/accuracy.html

bigger problem is the way the output of the LED fills the modes in the core of the
multimode fiber, discussed below.

For all measurements, systematic errors can be caused by testing with launch
cables that have bad connectors, especially fibers not centered in the ferrule or are
made with fibers with different core sizes (62.5 micron fiber cores can vary from about
60 to 65 microns.) Test this yourself, using a a light source and power meter and two
cables of 50 and 62.5 micron cores. Test loss single-ended in one direction and then
the other and note the enormous difference and how it is directional.

And, of course, the test method used (Method A, B or C for insertion loss or use of
reference cables with OTDRs) causes a systematic difference in measurements
depending on the unknown connection loss(es) included in the process of setting the
reference for "0 dB." (For more details on this, read "5 Ways" and "Loss Math.")

The biggest and perhaps most common systematic error in testing comes from
setting the reference power before testing. If a mistake is made during the reference
process or the launch cable is removed and replaced on the test source, the changes
in reference value will be reflected in every measurement. This is especially important
when testing at two wavelengths, as references should always be set with the meter
on the wavelength of measurement. Meters are calibrated at various wavelengths
because of the wavelength sensitivity of their detectors. Changing the meter calibration
setting can cause errors of several dB.

Dirt can also cause systematic errors if the reference cables are dirty when the
reference is set and cleaned afterwards during testing. If the dirt causes a big enough
loss when the reference is set, it may even cause measurements to show a "gain"
during tests - a real surprise for even experienced installers when they find "gainers"
during insertion loss tests, thinking that happens only during OTDR testing.

Random Errors in Fiber Optic Measurements

Random errors are errors that change with each measurement. Prove this yourself.
Using a light source and power meter (set on 0.01 dB resolution) connected with a
mating adapter and two patchcords tested single-ended. Mate and unmate the cables
numerous times and note the different losses which can vary by tenths of a dB. These
are random errors. If you can find a mating adapter with a plastic alignment sleeve, try
that over 10-100 matings and watch how the loss reading go up. Look at the end of the
connector and you see how dirty it gets from the plastic sleeve wearing against the
connector.

Speaking of dirt, that is one of the biggest causes of error. You should always clean
both connectors when testing a cable. Between testing, keep dust caps on the
connectors to prevent further contamination, but remember "dust caps" are often a
source of dust, so clean the connector before each measurement. Unless all the
connectors are carefully cleaned before each test, the condition of the end of the fiber
can cause large random errors.

Finally, all connectors wear with multiple insertions as the connectors end faces
mate and wear the endface polish. Over the course of many measurements, the loss
of reference cable connectors will increase slowly. The way to find this is to retest
against each other periodically and replace when loss gets unacceptable. Experienced
installers can repolish their connectors on diamond film like singlemode connectors,
but it may be more cost effective to replace the cables. And always keep a set of spare

5 of 11 01/05/2016 3:23 PM
The FOA Reference For Fiber Optics http://www.thefoa.org/tech/ref/testing/accuracy/accuracy.html

reference cables in the field.

Multimode Fiber Measurement Uncertainty

All test methods have uncertainties when testing fiber optic cable. Making accurate
loss measurements on fiber has been a constant and confusing subject of discussion
within the standards committees, especially with respect to multimode fibers. We have
tried to understand how light travels in multimode cable plants and how components
like connectors affect how that light travels. Then we tried to understand how the
losses of fiber, connectors and splices were affected by the methods used for testing.

We're going to explain, hopefully in understandable terms, how this works, how it
affects your measurements and how you can try to control test conditions to enhance
your test accuracy. It’s going to take some careful reading on your part, but when we’re
finished, you are going to be more knowledgeable, test faster and with less
measurement uncertainty.

How Light Travels In Multimode Fiber

The most important component affecting loss in a multimode cable plant is the
source coupling light into the fiber. Light sources may be LEDs or lasers. Lasers may
be VCSELs (vertical cavity surface-emitting lasers) or Fabry-Perot lasers (telecom
style.) Each of these emits light in a different pattern (right), with LEDs having the
broadest beam, F-P lasers a very narrow beam and VCSELs in between. The light
coupled from the source is transmitted in a multimode fiber in many rays or “modes,”
hence the name multimode. (below)

As you can see, a laser couples light only into modes that travel near the center of
the fiber while a LED couples light into practically all the modes. Look closely and you

6 of 11 01/05/2016 3:23 PM
The FOA Reference For Fiber Optics http://www.thefoa.org/tech/ref/testing/accuracy/accuracy.html

can see the modes near the center of the fiber core (lower-order modes) travel shorter
paths than the modes near the edges of the core (higher order modes.) The shorter
path of the lower-order modes means that they travel through less glass and suffer
less loss than the ones traveling in the outside of the core. That means a laser suffers
less attenuation (loss per unit length, in dB/km) in the same multimode fiber than a
LED.

Furthermore, as light travels down the fiber, the attenuation changes. The light in the
outside modes is attenuated, leaving mostly light in the modes near the center. At a
kilometer from a LED source, the light in the outer modes is mostly attenuated and the
light carried in the fiber looks more like the light launched from a laser. This means the
attenuation at that point is less than at the beginning because its only in lower order
modes.

So what is the loss of the fiber? The manufacturer’s spec for fiber is around 3 dB/km
at 850 nm and 1 dB/km at 1300 nm. That is for a test using a calibrated source that is
much closer to the launch of a laser source than a LED. The difference in the
attenuation coefficient of a fiber tested with a laser or LED can be 1-2 dB/km. With a
LED source, the first hundred meters of fiber – representative of a premises network –
may have an attenuation of over 4 dB/km.
The same factors hold for connector and spice loss. Most of the loss in connectors is
due to misalignment of the two fibers and the higher order modes are much more likely
to be lost at a connector than lower order modes. A connector coupled to a LED
source with a short cable could have a loss of 0.5 dB while if it were coupled to a laser
source or were 1 km away could have a loss of 0.3 dB.

By now, I suspect your head is swimming. If you still have your wits about you, you
may want to know how any standards body can solve this issue. The answer is how
everything is solved – compromise. Create a standard launch condition that is more
than a laser but less than a LED, which today is appropriate, since it’s more like the
VCSELs (vertical cavity surface-emitting lasers) used in today’s Gigabit and faster
multimode links.

Manufacturers use special lensed sources in their labs that can control the launch
conditions exactly. The way to approximate this launch for field testing is to use a LED
source and a mode modifier, usually a few turns of the reference launch cable wrapped
around a cylindrical mandrel that filters out the higher order modes. The mandrel size

7 of 11 01/05/2016 3:23 PM
The FOA Reference For Fiber Optics http://www.thefoa.org/tech/ref/testing/accuracy/accuracy.html

must chosen according to the fiber and cable type being used.(right, Table below)
These devices are available from many test equipment manufacturers.

It’s highly recommended that you use this standard source method, as it will
produce more consistent test results and provide greater reproducibility better if you
ever have to retest. And the losses measured are going to be lower so you are less
likely to fail good cables.

Even so, the uncertainty of the measurement is likely to be several tenths of a dB.
The uncertainty comes from the coupling of your reference cables to the fiber under
test, which includes the quality of the terminations on the reference cables, how clean
they are and how many times they have been used, since they degrade with use.

TIA-568 Specified Mandrel


Wrap five turns over the specified size mandrel
Cable/Fiber Type
900 micron Buffered
Fiber Size 3 mm Jacketed Cable
Fiber
50/125 22 mm 25 mm
62.5/125 17 mm 20 mm

Here are two other more technical articles on modal distribution and control in MM fiber
for testing.
Modal Effects on Multimode Fiber Loss Measurements
Encircled Flux For Multimode Fiber Measurements

So Why Aren’t OTDRs Used?

Some people think everybody uses OTDRs for all fiber optic testing, but that’s only
true for outside plant (OSP) applications. Most OSP installations involve splicing
singlemode fiber to get longer runs and the OTDR allows verifying the quality of the
splice. But when that link is finished, it must still be tested for insertion loss with a light
source, power meter and reference cables, just like premises cables. Premises cables
rarely have splices and are short, often too short for the OTDR to measure.

Insertion loss and OTDR testing use different methods. Insertion loss tests just like
the fiber will be used, with a source on one end and a detector on the other, so tested
insertion loss should be close to what the communications link actually will see.
OTDRs, however, make an indirect measurement, based on fiber scattering, the major
source of loss of a fiber. It sends a very powerful pulse down the fiber and some of the
scattering comes back toward the instrument, where it is measured and stored. As the
test pulse moves down the fiber (right), it takes a “snapshot” of the fiber illuminated by
the test pulse from which information about the fiber may be implied.

Everything the OTDR learns about the fiber is dependent on the amount of light
scattered back toward it and how the instrument is set up for the test. This
“backscatter” is a function of the materials in the fiber and the diameter of the core.

8 of 11 01/05/2016 3:23 PM
The FOA Reference For Fiber Optics http://www.thefoa.org/tech/ref/testing/accuracy/accuracy.html

Joints between two dissimilar fibers that have different backscatter coefficients will not
allow one way measurements. One way the loss is too high, the other way too low
(maybe even a “gainer” where the change in backscatter is more than the loss of the
connection.)

The second problem with OTDRs on multimode fiber is the laser source. As
mentioned above, lasers couple light narrowly into multimode fiber and will measure
lower attenuation and connector or splice loss than recommended by standards on the
outward bound test pulse, but scattered light probably overfills the fiber, even more
than a LED on the return. To date, we are unaware of anyone who has modeled this
and can provide guidance on the expected test results from an OTDR.

In addition, there are problems in premises applications with OTDR distance


resolution. Light travels about 1 meter in 5 nanoseconds. The width of the test pulse is
usually 10-30 ns and the minimum resolution of the OTDR is about 3 times that or 2-6
meters. Highly reflective events like multimode connectors in premises cabling, cause
instrument overload and lengthen the minimum resolution of the instrument. Only a few
specialized OTDRs have the resolution needed for premises cabling.

OTDRs are complicated instruments. Before the OTDR is used to make a


measurement, you have to set all these parameters correctly: range, wavelength,
pulse width, number of averages, index of refraction of the fiber and the measurement
method (usually 2 types for each measurement.) OTDR manufacturers should teach
you how to set up the OTDR properly and how to interpret the rather complicated
display. (left). But few customers are willing to invest the day or two necessary to learn
how to use the instrument properly. So manufacturers create an “autotest” function like
a Cat 6 certifier that tests the fiber and gives you a pass/fail result. Every debacle I
have seen in OTDR testing resulted from inadequately trained personnel using
autotest.

9 of 11 01/05/2016 3:23 PM
The FOA Reference For Fiber Optics http://www.thefoa.org/tech/ref/testing/accuracy/accuracy.html

Unfortunately, because of their indirect measurement technique, OTDRs do not


easily correlate with insertion loss tests, and that’s why they are not allowed by
industry standards to be use alone. Some users claim to have been able to control
modal power in multimode fiber and get correlation between OTDRs and insertion loss
tests, but results are hard to duplicate. The FOA did a comprehensive comparison test
ourselves using special mode conditioners and were unable to get correlation. In fact,
some of our tests gave divergent results between two different OTDRs!

If one considers the OTDR test to be a “qualitative” not “quantitative” test, and one
knows how to interpret the OTDR trace properly, one can determine if connectors and
splices are properly installed and if any damage has been done to the cable during
installation. If the user does not have the experience and knowledge to do a proper
analysis, the device usually only causes problems.

Testing Efficiently And Accurately

The contractor and the user should agree on what documentation and testing are
required before the project is started. That documentation should include the layout of
the cabling, types and numbers of fiber in each cable, connection diagrams and
insertion loss test results. That agreement should be part of the bid and the contract. If
the customer wants OTDR data, they should be quizzed on why they want it and be
made to understood that OTDR testing is time consuming and expensive (like the
instrument itself!)

Before beginning the installation, the contractor should calculate a loss budget for
each link based on the length of the link and the number of connections. This confirms
the equipment will operate over that link. Then the expected loss will be known to allow
a pass/fail decision by the person doing the testing. The contractor should have the
proper test equipment and installers using the equipment should be familiar with its
use.

When terminating cables, each cable should be tested with a source and power
meter using high quality reference cables. The accuracy of the measurements
depends on having properly operating test equipment, high quality reference cables
with a mandrel wrap, cleaning all connections before every measurement and using a
consistent measurement technique.

10 of 11 01/05/2016 3:23 PM
The FOA Reference For Fiber Optics http://www.thefoa.org/tech/ref/testing/accuracy/accuracy.html

Reference cables should be tested with the same test equipment they are used with
each day and cleaned carefully before each measurement. This also provides good
practice to the installers using the equipment. All installers using the test equipment
should be familiar with using the mandrel wrap on the launch cables.

Since the light source and power meter insertion loss test requires an instrument at
each end of the cable, two installers working together will speed up the process. A
visual tracer can be used to identify the next fiber to test, making communication
easier and cheaper than using cell phones.

Data should be recorded in a spreadsheet alongside the loss budget calculation


used for pass/fail criteria so the contractor and customer can verify the installation.
Troubleshoot high loss links that fail testing by testing “single ended” with only a launch
cable. Bad connections will show up as high loss when connected to the launch cable
but not when connected directly to a power meter so reversing the cable test direction
will usually find bad connectors.

Return to the FOA Online Fiber Optic Reference Guide Table of Contents

(C)1999-2014, The Fiber Optic Association, Inc.