Anda di halaman 1dari 4

BHT-407-MM-3

CHAPTER 26 — FIRE PROTECTION

TABLE OF CONTENTS

Paragraph Chapter/Section Page


Number Title Number Number

FIRE PROTECTION

26-1 Fire Protection................................................................................ 26-00-00 3


26-2 Hand Fire Extinguisher ............................................................. 26-00-00 3
26-3 Hand Fire Extinguisher — Inspection ............................... 26-00-00 3
26-4 Heat Sensing System ............................................................... 26-00-00 3

FIGURES

Figure Page
Number Title Number

26-1 Fire Extinguisher ................................................................................................. 4

26-00-00
ECCN EAR99 23 DEC 2009 Rev. 26 Page 1/2
BHT-407-MM-3

FIRE PROTECTION

26-1. FIRE PROTECTION FIRE EXTINGUISHER BEFORE YOU


RETURN IT TO SERVICE.
The fire protection system for the helicopter is made
up of a hand fire extinguisher installed in the flight 2. Examine the pressure indicator and make sure
compartment. An optional heat sensing system that the indicator needle is in the green area. For
installed in the engine compartment is available. instructions on how to service the fire extinguisher,
refer to Chapter 12.
26-2. HAND FIRE EXTINGUISHER
3. Examine the quick release latch. Make sure that
The hand fire extinguisher is installed in the flight the latch opens easily and locks correctly.
compartment. It is made up of a fire extinguisher bottle
(1, Figure 26-1) and a mounting bracket (2). The fire 4. Examine the mounting bracket. Make sure that
extinguisher bottle is made up of a rechargeable body, the bracket is installed correctly on the center post.
a safety catch, a discharge nozzle, a red discharge
indicator disc, and a pressure indicator. The mounting
bracket is installed on the center post and has a quick 26-4. HEAT SENSING SYSTEM
release latch.
NOTE
26-3. Hand Fire Extinguisher — Inspection
The heat sensing system is only available
1. Examine the hand fire extinguisher for signs of as an optional kit. It is not standard
damage, corrosion, and pitting. equipment on the helicopter.

The heat sensing system for the helicopter is made up


of a Fenwall firewire. It is installed in the engine
CAUTION compartment. The firewire detects an overheat
condition in the engine compartment and supplies a
signal to the caution and warning panel. For the
IF THE FIRE EXTINGUISHER HAS BEEN extended description and operation of the heat
FIRED, DO NOT USE IT. RECHARGE THE sensing system, refer to Chapter 96.

26-00-00
ECCN EAR99 23 DEC 2009 Rev. 26 Page 3
BHT-407-MM-3

1. Fire extinguisher
2. Mounting bracket

NO OBJECT BEYOND THIS POINT 407_MM_26_0001

Figure 26-1. Fire Extinguisher

26-00-00
Page 4 Rev. 26 23 DEC 2009 ECCN EAR99