Anda di halaman 1dari 1

A3

4 3
2575

+300

200
200mm THK CONC. SLAB ON
50mm THK CONC. BLINDING ON

1200

1200
APPROVED 0.25mm THK HEAVY DUTY POLYTHENE
DAMP PROOF MEMBRANE ON

150mm THK LAYER OF GRANITE HARDCORE OF


MAXIMUM AGG. SIZE 100mm HAVING LEVELLED
SURFACE SAND FILLING AND VERY WELL
COMPACTED ON

WELL COMPACTED APPROVED FILLED MATERIAL


TO MAKE UP LEVELS AS REQUIRED PLACED AND
COMPACTED IN LAYERS NOT EXCEEDING 200mm THK ON
250 250
WELL COMPACTED SUBGRADE (TYPICAL)

SECT. L03
1

C D 2 1
2365
3500
200

+300
+300

200
+0
+0
1200

1200

1200

1200
250 250 250 250

SECT. L03 SECT. L03


2 3

SIROC Engineering Consultants


NOTES: Drawing Title
Consulting Engineers and Project Managers.
NOTES APPLICABLE TO THIS DRAWING
L0039/-/G/01
Job Title 23 Olatunde Ayoola Avenue, Anthony,
1. SEE GENERAL NOTES ON DRAWING NO. ................... The Contractor is to check all drawings Lagos,
2. REINF. LISTED ON BENDING SCHEDULE/S PAGES.........
before starting work and any discrepancies MR EMEKA EMENIKE MAIN BUILDING Lagos State, Nigeria.
3. DRAWING DONE ORIGINALLY ON THE PAPER SIZE Email: engrrozay@gmail.com
found on this drawing or between this drawing Tel. nos: +234(0)8064458336
INDICATED ON THE TOP LEFT CORNER
and any other drawing issued by any party Description By
are to be brought to the notice of the
RESIDENTIAL DEVELOPMENT AT ROAD 13 FOUNDATION /GROUND FLOOR LAYOUT - Scales Date
Drawn NJE 04-10-2017
Engineers immediately. Indicated dimensions are
LEKKI PHASE 1, LEKKI, LAGOS STATE. SECTIONS 1 : 25 Checked: AII 04-10-2017
in mm unless otherwise stated. Dimensions are Mark Date by Revision Approved AII 04-10-2017
to be confirmed on site. Drawing Status Job No: Revision

FOR PLANNING APPROVAL L0039 MB L 04