Data :
Proses di HE-04
= 631354,7453 J/s
= 60246,97534 J/s
= 7470,635366 J/s
= 386885,5236 J/s
1𝐵𝑡𝑢 3600 𝑠
Konversi q total = 1085957,88 J/s x 1055,056 𝐽 x 1ℎ
= 3705441,577 Btu/h
q total = U x A x∆T
A = q total / (U x ∆T)
3705441,577 Btu/h
A = 𝐵𝑡𝑢 = 171,55 ft2 = 172 ft2 (untuk perancangan)
100 x (500−284) °F
ℎ.𝑓𝑡2 .°F
Penentuan Harga
http://www.matche.com/equipcost/Exchanger.html
Area = 172 ft2