OWNER’S MANUAL
The exclamation point within an The lightning flash with arrowhead The “Caution, hot surface” symbol
equilateral triangle and "WARNING" symbol, within an equilateral indicates that the marked item may
are intended to alert the user to the triangle, is intended to alert the user be hot.
presence of important operating or to the presence of un-insulated
servicing instructions. Failure to ‘dangerous voltage’ within the Do not cover or block ventilation
heed the instructions will result in product’s enclosure that may be of openings. Ensure the apparatus is
severe injury or death. sufficient magnitude to constitute a installed with plenty of space around
risk of electric shock to persons. the unit (> 6”/12.5cm) as this
This equipment should be used Terminals labelled as “SPEAKER apparatus may generate heat under
under the supervision of an adult OUTPUTS” must be connected to a normal use. This equipment is not WARNING
at all times. speaker cabinet of the designated intended to be used on soft support DO NOT TAMPER WITH VOLTAGE
load (Ω) rating using an un-shielded (like beddings, blankets etc.). This
two conductor cable for speaker use equipment should always be placed FUSE INFORMATION SELECTOR SWITCH
at all times during operation. on a flat, stable surface.
The mains fuse is provided for your safety. The
fuse rating for your model and region is indicated
near the unit’s AC mains inlet
2 3
GENERAL USE FRONT PANEL
Before switching on the power, set the unit’s volume control(s) to minimum.
OFF HALF DIRTY
Ensure the correct speaker load is connected at all times during operation.
Refer to the section entitled “SPEAKER OUTPUTS”
Use good quality shielded instrument cable to connect your instrument to your unit’s input. ON STBY
FULL
NATURAL
To prevent excessive hum and electrical noise, operate your amplifier and instruments as
far away as possible from other electronic devices. Examples include: refrigerators, motors,
air conditioners, television sets, radio receivers etc.
The Natural Channel gives the purest route The Dirty Channel can be set clean or
from guitar to speaker with just a single volume distorted by balancing where the gain and
control. It has no EQ controls but is voiced to volume controls are set. Lower gain
START UP PROCEDURE SERVICING INFORMATION FOR complement your guitar’s natural tone. As a settings will produce cleaner tones.
FOR VALVE AMPLIFIERS VALVE AMPLIFIERS ‘non-master’-style channel, the output valves
will begin to saturate into overdrive at high Note: The EQ controls only affect the
volume settings. Dirty Channel.
Before switching the POWER switch to the ON position, Periodic valve renewal should be considered part of
ensure the HALF/STBY/FULL switch is set to the owning a quality valve [tube] amplifier. The rate of valve
STBY (Startup Tension Bypass) mode. wear is dependent on many factors, but if you notice a
change in the performance of your amplifier, it is likely a
Leave the amp in STBY mode for at least 2 minutes result of valve decline. Valves can fail at any time.
prior to performance. This will help prolong the life of Output valves (EL84, EL34, 6550 etc.) are subject to ORANGE ICONS DIRTY CHANNEL EQ
the valves [tubes]. After 2 minutes, switch to play mode more stress than preamp valves (12AX7, 12AT7 etc.)
(FULL or HALF power). Select the STBY mode during and may require more regular replacement. Consult
breaks in performance. your service centre/dealer for more information. GAIN
INPUT Controls the (preamplifier) gain level.
¼” instrument jack socket. Higher settings produce more
Output valves should always be distortion. Note: When set to minimum,
replaced with matched sets, though no sound will be heard.
not all models require a bias
adjustment. Contact your POWER
The lamp will illuminate to indicate the
Orange dealer for more BASS
power is switched to ON.
information. Adjusts the lower frequency response.
Increasing the bass produces deeper
Refer to page 4 for the
Bias adjustment should sounds.
HALF/STBY/FULL switch.
only be performed by
authorised service MID
personnel. CHANNEL Adjusts the midrange response.
Toggles between the Natural and Dirty
Increasing the mids creates
channel. This can be switched remotely
The fuse labelled "HT using an optional footswitch (see rear).
a fatter sound, whilst reducing
FUSE" will blow in the ‘scoops’ the tone.
event of output valve
failure. The output valve(s)
should be replaced, and VOLUME TREBLE
Adjusts the high frequency response.
SELECTING STBY OR PLAY MODE: the HT fuse replaced with Adjusts the volume level for either the
Increase the treble for brighter tones
the correct 250V type. Natural or Dirty channel.
or reduce for a warmer sound.
OUTPUT (FULL / HALF) The rating is indicated on
This switch toggles between FULL and HALF the product near the HT
power modes. In HALF power mode, the volume fuse holder.
will be reduced and output valve overdrive can be REAR ICONS
achieved at lower output levels. The centre Our Orange Valve Tester
position selects STBY mode. can be used to help match
valves and check valve FX LOOP
Used to place external effects between the FOOTSWITCH
health. Connect a latching footswitch (e.g.
amplifier’s preamplifier section and output
section. Connect the SEND jack to the input Orange FS-1) to remotely select between
Visit orangeamps.com for of external effects. Connect the output of Natural and Dirty channels.
more information. external effects to the RETURN jack.
4 5
REAR CONNECTIONS
The HEADROOM/BEDROOM attenuator
switch works with the FULL/STBY/HALF
switch on the top panel to vary the output power:
HEADROOM (FULL) = 15 Watts
HEADROOM (HALF) = 7 Watts
BEDROOM (FULL) = 1 Watt
BEDROOM (HALF) = 0.5 Watt
SPEAKER
( 16 Ω )
OUT IN
MONO
PEDAL
1 x 16Ω CABINET
SPEAKER OUTPUTS
THE ROCKER 15 TERROR MUST BE CONNECTED
TO A SPEAKER LOAD (Ω) AT ALL TIMES DURING
1 x SPEAKER ( 16 Ω ONLY)
OPERATION.
1 x 8Ω CABINET
1 x SPEAKER ( 8 Ω ONLY )
6 7