Anda di halaman 1dari 4

Project: FOUNDATION DESIGN Page # ___

Engineer: 4/24/2019
Descrip: A3-B3
ASDIP Foundation 3.2.2 COMBINED FOOTING DESIGN www.asdipsoft.com

GEOMETRY SOIL PRESSURES (Comb: Service)


Column to Column Distance .... 5.31 ft Gross Allow. Soil Pressure ..... 3.10 ksf
Exterior Interior Overburden Pressure ............. 0.56 ksf
Column Length (X) .... 12.0 12.0 in Reaction Force ....................... 20.8 kip
Column Width (Z) ...... 12.0 12.0 in Reaction Eccentricity .............. 0.00 ft
Edge Distance (X) ..... 1.00 1.00 ft OK Ftg. Area in Contact with Soil ...... 100.0 %
Footing Width (Z) ....... 5.00 5.00 ft Exterior Interior
Footing Thickness .............. 18.0 in OK Bearing Pressure ...... 0.57 0.57 ksf
Soil Cover ........................... 2.99 ft Bearing Ratio ............ 0.18 0.18 OK
Pedestal Height .................. N. A.

APPLIED LOADS SLIDING (Comb. Service)


- Exterior Col. Service Factored Footing-Soil Friction Coeff. ......... 0.45
Axial Force P ........... 0.0 58.4 kip Passive Pressure Coeff. Kp ........ 2.77
Moment about Z Mz 0.0 18.4 k-ft Friction Force at Base ............ 9.4 kip
Shear Force Vx ........ 0.0 9.0 kip Passive Force @ Ftg .............. 8.9 kip
- Interior Col. Service Factored Horiz. Resisting Force ............ 18.3 kip
Axial Force P ........... 0.0 107.0 kip Horiz. Sliding Force ................ 0.0 kip
Moment about Z Mz 0.0 14.7 k-ft Sliding Safety Factor .............. 99.99 > 1.5 OK
Shear Force Vx ........ 0.0 107.0 kip

MATERIALS
Columns Footing
Concrete f'c ............. 2.9 2.9 ksi
Reinf. Steel fy .......... 72.5 72.5 ksi
Soil Cover Density ................. 115.0 pcf

DESIGN CODES
Concrete Design ................ IS 456:2000
Load Combinations ............ User-defined

1 of 4
Project: FOUNDATION DESIGN Page # ___
Engineer: 4/24/2019
Descrip: A3-B3
ASDIP Foundation 3.2.2 COMBINED FOOTING DESIGN www.asdipsoft.com

OVERTURNING CALCULATIONS (Comb: Service)


OVERTURNING RESISTING
Force Arm Moment Force Arm Moment
- About Z-Z kip ft k-ft - About Z-Z kip ft k-ft
Ext. Moment Mz ... 0.0 0.0 0.0 Soil Cover ........... 11.9 3.66 43.4
Ext. Shear Vx ....... 0.0 1.50 0.0 Footing Weight ... 8.7 3.66 31.9
Ext. Axial P .......... 0.0 1.00 0.0 Ext. Column ........ 0.0 1.00 0.0
Int. Moment Mz .... 0.0 0.0 0.0 Int. Column .......... 0.0 6.31 0.0
Int. Shear Vx ........ 0.0 1.50 0.0 Ext. Axial P .......... 0.1 1.00 0.1
Int. Axial P .......... 0.0 6.31 0.0 Int. Axial P ........... 0.1 6.31 0.6
Passive Pressure 0.0 0.60 0.0 Water Buoyancy . 0.0 3.66 0.0
Rh = 0.0 OTM = 0.0 Rv = 20.8 RM = 76.0
Arm of Vertical Resultant .... 3.66 ft
Overturning Safety Factor .. 99.99 > 1.5 OK

FOOTING AT EXTERIOR COL.


- One-way Shear (Comb: Factored)
Under-strength ϕ Factor ............. 0.75
- Side + Side
One-way Shear Vux ... 0.0 52.5 kip
Shear Strength ϕVcx .. 70.4 70.4 kip
Max. One-way Shear Ratio Vu/ϕVc .. 0.75 OK
- Punching Shear (Comb: Factored)
Unbalanced Moment Factor Ɣvx ... 0.39
Punching Shear due to Axial .... 26.1 psi
Punching Shear due to Mz ....... 7.8 psi
Punching Shear Stress Vu ...... 33.9 psi
Effective Perimeter bo ............. 77.1 in
Average Effective Depth d ...... 14.5 in
Punching Shear Strength ϕVc .. 161.6 psi
Punching Shear Ratio Vu/ϕVc ....... 0.21 OK
- Transv. Flexure (Comb: Factored)
Under-strength ϕ Factor ............. 0.90
Footing Effective Length ............. 3.19 ft
Use 12 D12 Bars Parallel to Z (Top) , d = 15.3 in
Use 12 D12 Bars Parallel to Z (Bot) , d = 14.3 in
Bottom Steel Min. Area Ratio ........ 0.59 OK
Top Bot
Bending Moment Mux .. 0.0 34.5 k-ft
Bending Strength ϕMnx 165.4 154.0 k-ft
Max. Bending Ratio Mux/ϕMnx ....... 0.22 OK
Top Z-Bars Develop. Length Ratio . 0.27 OK
Bot Z-Bars Develop. Length Ratio .. 0.29 OK 2 of 4
Project: FOUNDATION DESIGN Page # ___
Engineer: 4/24/2019
Descrip: A3-B3
ASDIP Foundation 3.2.2 COMBINED FOOTING DESIGN www.asdipsoft.com

FOOTING AT INTERIOR COL. LOAD TRANSFER (Comb: Factored)


- One-way Shear (Comb: Factored) Bearing Under-strength ϕ Factor ....... 0.65
Under-strength ϕ Factor ............. 0.75 Ext. Int.
- Side + Side Compressive Stress Pu 1.2 1.4 ksi
One-way Shear Vux ... 60.6 9.2 kip Column Bearing ϕPn ..... 2.6 2.6 ksi OK
Shear Strength ϕVcx .. 70.4 70.4 kip Footing Bearing ϕPn ..... 4.2 4.2 ksi OK
Max. One-way Shear Ratio Vu/ϕVc .. 0.86 OK Shear Force Vu ............. 0.0 0.0 kip
- Punching Shear (Comb: Factored) Shear Friction ϕVn ........ 101.8 101.8 kip OK
Unbalanced Moment Factor Ɣvx ... 0.39 Dowel Steel Area As ..... 3.12 3.12 in²
Punching Shear due to Axial .... 84.1 psi Min. Steel Area As min .. 0.72 0.72 in² OK
Punching Shear due to Mz ....... 6.2 psi Dev. Length Ratio at Col. 0.50 0.50 OK
Punching Shear Stress Vu ...... 90.3 psi Dev. Length Ratio at Ftg. 0.40 0.40 OK
Effective Perimeter bo ............. 77.1 in
Average Effective Depth d ...... 14.5 in
Punching Shear Strength ϕVc .. 161.6 psi
Punching Shear Ratio Vu/ϕVc ....... 0.56 OK
- Transv. Flexure (Comb: Factored)
Under-strength ϕ Factor ............. 0.90
Footing Effective Length ............. 3.19 ft
Use 12 D12 Bars Parallel to Z (Top) , d = 15.3 in
Use 12 D12 Bars Parallel to Z (Bot) , d = 14.3 in
Bottom Steel Min. Area Ratio ........ 0.59 OK
Top Bot
Bending Moment Mux .. 0.0 23.3 k-ft
Bending Strength ϕMnx 165.4 154.0 k-ft
Max. Bending Ratio Mux/ϕMnx ....... 0.15 OK
Top Z-Bars Develop. Length Ratio . 0.27 OK
Bot Z-Bars Develop. Length Ratio .. 0.29 OK

LONGITUDINAL REINF.
- Long. Flexure (Comb: Factored)
Use 12 D12 Bars Parallel to X (Top) , d = 15.8 in UPLIFT CALCS (Comb: Service)
Use 15 D12 Bars Parallel to X (Bot) , d = 14.8 in Uplift Force P ....................... 0.0 kip
Top Bot Pedestals Selfweight ............ 0.0 kip
Min. Steel Area Ratio ... 0.23 0.99 OK Footing Selfweight ................ 8.7 kip
Bending Moment Muz .. 30.5 182.5 k-ft Soil Cover Weight ................. 11.9 kip
Bending Strength ϕMnz 174.1 201.5 k-ft Downward Force W ............. 20.6 kip
Max. Bending Ratio Muz/ϕMnz ....... 0.91 OK Uplift Safety Factor ............... 99.99 > 1.0 OK
Ext. Bot X-Bars Dev. Length Ratio . 0.40 OK
Int. Bot X-Bars Dev. Length Ratio ... 0.40 OK

3 of 4
Project: FOUNDATION DESIGN Page # ___
Engineer: 4/24/2019
Descrip: A3-B3
ASDIP Foundation 3.2.2 COMBINED FOOTING DESIGN www.asdipsoft.com

EXT. COLUMN (Comb: Factored) INT. COLUMN (Comb: Factored)


Use 10-D16 Longitudinal Bars, Use Ties D8 Use 10-D16 Longitudinal Bars, Use Ties D8
Axial Load Pu ...................... 58.4 kip Axial Load Pu ...................... 107.0 kip
Bending Moment Mu ............. 18.4 k-ft Bending Moment Mu ............. 14.7 k-ft
Axial Strength ϕPn ................ 298.2 kip Axial Strength ϕPn ................ 298.2 kip
Flexural Strength ϕMn .......... 56.9 k-ft Flexural Strength ϕMn .......... 51.8 k-ft
Biaxial Strength Ratio ................. 0.32 OK Biaxial Strength Ratio ................. 0.36 OK

4 of 4

Anda mungkin juga menyukai