Anda di halaman 1dari 1

Tabla LI.

Armados de vigas del primer nivel


Tramo Armado propuesto

Cama Corridos Bastones


(−) 8.91 1 No. 5 + 1 No. 4 8.95
Superior 2 No.6 2 No. 6 + 2 No.4
M–N (−) 15.61 15.91
+ 1 No. 5
2 No.6 + 2
(+) 2.01 Inferior --- 9.66
No. 5
(−) 8.86 1 No. 5 + 1 No. 4 8.95
Superior 2 No.6 2 No. 6 + 2 No.4
N–Ñ (−) 15.52 15.91
+ 1 No. 5
2 No.6 + 2
(+) 2.01 Inferior --- 9.66
No. 5
(−) 8.87 1 No. 5 + 1 No. 4 8.95
Superior 2 No.6 2 No. 6 + 2 No.4
Ñ–O (−) 16.12 15.91
+ 1 No. 5
2 No.6 + 2
(+) 1.80 Inferior --- 9.66
No. 5
(−) 8.86 1 No. 5 + 1 No. 4 8.95
Superior 2 No.6 3 No. 6 + 1 No.4
O–P (−) 17.58 15.50
+ 1 No. 5
2 No.6 + 2
(+) 3.33 Inferior --- 9.66
No. 5
(−) 8.91 1 No. 5 + 1 No. 4 8.95
Superior 2 No.6 3 No. 6 + 2 No.4
P–Q (−) 17.76 18.76
+ 1 No. 5
2 No.6 + 2
(+) 4.04 Inferior --- 9.66
No. 5
Fuente: elaboración propia.

El código ACI 318S-14, sección 9.7.2.3, establece que para vigas en la cual
la separación entre camas de acero excede 14 pulgadas, es necesario colocar
refuerzo adicional en el centro, para evitar agrietamiento causado por las fuerzas
internas producidas por el fraguado; el código especifica que debe ser
1.61 por cada pie de altura, para nuestra viga deberían de colocarse 2.64
(1.61 ∗ 1.6 ) como refuerzo adicional, por lo tanto se colocaran 2 varillas