1. SCOPE
This specification provides the list of International Codes and Industry Standards which will
govern the design and construction of the ONSHO RE FACILITIES f or SOUTH PARS GAS
FIELD Phase 12.
2. INSTRUCTIONS
The proj ect facilities shall be designed, engineered, built, installed and comm issioned to the
latest relevant international codes and standards. Other references stated in these
standards shall also apply. These reference docum ents shall be the latest revision at the
date of Call for T enders.
CONTRACTOR shall be responsible for check ing consistency of specif ied docum ents and
informing COMPANY of any interpretation prior to application.
The list attached concern only the Codes & Standards, it is understood that com pulsory
regulations (local/international) shall be applied.
The list attached is general and not exhaustive, it shall not restrict the requirem ent
m entioned in the specifications or other docum entation.
ASME SECTION II, Parts ABCD ASME Boiler & Pressure Vessel Code & Materials
ASME SECTION IX ASME Boiler & Pressure Vessel Code, W elding and
Brazing Qualification
A S M E S e c ti o n V Non-destructive examination
A S M E B 16. 47 Large diam eter steel flanges (NPS 26 Through NPS 60)
ASME B 16.5 P i p e Fl a n g e s a n d Fl a n g e d Fi t t i n g s
NACE
NACE MR0175/ISO 15156 Petroleum and Natural Gas Industries Materials for use in
H2S-Containing Environm ents in Oil and Gas production.
EN
Others
D iv is i o n I I I = W in d D e s i g n
This document is the property of N.I.O.C. Any unauthorised attempt to reproduce it, an any form, is strictly
prohibited.
ﺳﺎﻳﺖ ﻣﺮﺟﻊ ﺑﺎﺯﺭﺳﻲ ﻓﻨﻲ ﻭ ﻛﻨﺘﺮﻝ ﻛﻴﻔﻴﺖ
EEMUA Publication No. 143 Recomm endations for Tube end W elding.
AI S C
A S CE
3.3 Heaters-Boilers
B S 2486 Treatm ent of W ater for Steam Boiler and W ater Heater
This document is the property of N.I.O.C. Any unauthorised attempt to reproduce it, an any form, is strictly
prohibited.
ﺳﺎﻳﺖ ﻣﺮﺟﻊ ﺑﺎﺯﺭﺳﻲ ﻓﻨﻲ ﻭ ﻛﻨﺘﺮﻝ ﻛﻴﻔﻴﺖ
ASME SECTION II, Parts ABCD ASME Boiler & Pressure Vessel Code & Materials
ASME SECTION IX ASME Boiler & Pressure Vessel Code & W elding
Procedures
ASME B 16.5 P i p e Fl a n g e s a n d Fl a n g e d Fi t t i n g s
B S 729 Hot dip Galv anised Coatings on Iron & Steel Articles
EEMUA Publication No. 143 Recomm endation for Tube end W elding
B S 2486 Treatm ent of W ater for Steam boiler and W ater Heater
Replace ASTM F 871 and ASTM B 644 with ASTM A153 / A 153M Specification for Zinc
ASCE 7-05 Minimum Design Loads for Buildings and other Structures
This document is the property of N.I.O.C. Any unauthorised attempt to reproduce it, an any form, is strictly
prohibited.
ﺳﺎﻳﺖ ﻣﺮﺟﻊ ﺑﺎﺯﺭﺳﻲ ﻓﻨﻲ ﻭ ﻛﻨﺘﺮﻝ ﻛﻴﻔﻴﺖ
Ref erence
ASME A 58-1 Building Code Requirem ents for m inimum Design load in
buildings and other structures
A PI 6 5 1 Cathodic Protection
C y l i n d r i c a l Ta n k s
NACE
NACE MR0175/ISO 15156 Petroleum and Natural Gas Industries Materials for use in
H2S-Containing Environm ents in Oil and Gas production.
UB C Volume 2 Chapter 16
D iv is i o n I I I = W in d D e s i g n
This document is the property of N.I.O.C. Any unauthorised attempt to reproduce it, an any form, is strictly
prohibited.
ﺳﺎﻳﺖ ﻣﺮﺟﻊ ﺑﺎﺯﺭﺳﻲ ﻓﻨﻲ ﻭ ﻛﻨﺘﺮﻝ ﻛﻴﻔﻴﺖ
P a ge : 9 of 50
B S 5896 Specification for High Tensile Steel W ire and Strand for
the Prestressing of Concrete
A PI 6 5 1 Cathodic Protection
Others
AISI E-I Steel Plate Engineering Data Series: Useful Inform ation –
Design Of Plate Structure, Volume II
This document is the property of N.I.O.C. Any unauthorised attempt to reproduce it, an any form, is strictly
prohibited.
ﺳﺎﻳﺖ ﻣﺮﺟﻊ ﺑﺎﺯﺭﺳﻲ ﻓﻨﻲ ﻭ ﻛﻨﺘﺮﻝ ﻛﻴﻔﻴﺖ
Steel Plates.
UB C Volume 2 Chapter 16
D iv is i o n I I I = W in d D e s i g n
API RP 11 Recom m ended Practices for Pack aged Com bustion Gas
T urbi nes
This document is the property of N.I.O.C. Any unauthorised attempt to reproduce it, an any form, is strictly
prohibited.
ﺳﺎﻳﺖ ﻣﺮﺟﻊ ﺑﺎﺯﺭﺳﻲ ﻓﻨﻲ ﻭ ﻛﻨﺘﺮﻝ ﻛﻴﻔﻴﺖ
This document is the property of N.I.O.C. Any unauthorised attempt to reproduce it, an any form, is strictly
prohibited.
ﺳﺎﻳﺖ ﻣﺮﺟﻊ ﺑﺎﺯﺭﺳﻲ ﻓﻨﻲ ﻭ ﻛﻨﺘﺮﻝ ﻛﻴﻔﻴﺖ
IS O 1 0 8 1 6 Mechanical Vibration
Others
NACE MR0175/ISO 15156 Materials for use in H2S – containing Environm ents in Oil
a n d G a s P r o d u c ti o n
This document is the property of N.I.O.C. Any unauthorised attempt to reproduce it, an any form, is strictly
prohibited.
ﺳﺎﻳﺖ ﻣﺮﺟﻊ ﺑﺎﺯﺭﺳﻲ ﻓﻨﻲ ﻭ ﻛﻨﺘﺮﻝ ﻛﻴﻔﻴﺖ
3.8 P i pi n g
ASME B 1.2 G a g e s a n d G a g i n g f o r U n if i e d I n c h S c r e w T h r e a d s
ASME B.16.1 Cast Iron Pipe Flanges and Flanged Fittings Class 125
(Flat Face)
ASME B 16.5 P i p e Fl a n g e s a n d Fl a n g e d Fi t t i n g s
ASME B16.24, C a s t C o p p e r A l l o y P i p e Fl a n g e s a n d Fl a n g e d Fi t t i n g s
ASME B16.28 W rought Steel Butt-W elding Short Radius Elbows and
Returns
ASME B18.2.1 Square and Hex Bolts and Screws (Inch Series)
This document is the property of N.I.O.C. Any unauthorised attempt to reproduce it, an any form, is strictly
prohibited.
ﺳﺎﻳﺖ ﻣﺮﺟﻊ ﺑﺎﺯﺭﺳﻲ ﻓﻨﻲ ﻭ ﻛﻨﺘﺮﻝ ﻛﻴﻔﻴﺖ
ASME SEC. III Rules for Construction of Nuclear Facility Com ponents
This document is the property of N.I.O.C. Any unauthorised attempt to reproduce it, an any form, is strictly
prohibited.
ﺳﺎﻳﺖ ﻣﺮﺟﻊ ﺑﺎﺯﺭﺳﻲ ﻓﻨﻲ ﻭ ﻛﻨﺘﺮﻝ ﻛﻴﻔﻴﺖ
A PI 5 L Line Pipe
W RC 107 and 297 W elding Research Council Bulletins 107 & 297
MSS SP6 Standard Finishes for Contact Faces of Pipe Flanges and
connecting ends Flanges of Valves and Fittings
MSS SP9 Spot Facing for Bronze, Iron and Steel Flanges
This document is the property of N.I.O.C. Any unauthorised attempt to reproduce it, an any form, is strictly
prohibited.
ﺳﺎﻳﺖ ﻣﺮﺟﻊ ﺑﺎﺯﺭﺳﻲ ﻓﻨﻲ ﻭ ﻛﻨﺘﺮﻝ ﻛﻴﻔﻴﺖ
ASTM A106 Standard Specification for Seam less Carbon Steel Pipe
for High-Temperature Service
ASTM A153 Zinc Coating (Hot Dip) on Iron and Steel Hardware
This document is the property of N.I.O.C. Any unauthorised attempt to reproduce it, an any form, is strictly
prohibited.
ﺳﺎﻳﺖ ﻣﺮﺟﻊ ﺑﺎﺯﺭﺳﻲ ﻓﻨﻲ ﻭ ﻛﻨﺘﺮﻝ ﻛﻴﻔﻴﺖ
or Both
ASTM A217 Martensitic Stainless Steel and Alloy Steel Castings for
Pressure Containing Parts Suitable for High Tem perature
Service
ASTM A307 Standard Specification for Carbon Steel Bolts and Studs,
60 000 PSI Tensile Strength
ASTM A333 Standard Specification for Seam less and W elded Steel
Pipe for Low-Tem perature Service
This document is the property of N.I.O.C. Any unauthorised attempt to reproduce it, an any form, is strictly
prohibited.
ﺳﺎﻳﺖ ﻣﺮﺟﻊ ﺑﺎﺯﺭﺳﻲ ﻓﻨﻲ ﻭ ﻛﻨﺘﺮﻝ ﻛﻴﻔﻴﺖ
ASTM A691 Standard Specification for Carbon and Alloy Steel Pipe,
Electric-Fusion-W elded for High-Pressure Service at High
Tem peratures
ASTM A790 Seam less and W elded Ferritic / Austenitic Stainless Steel
Pipe ASTM A 815 W rought Ferritic / Austenitic Stainless
Steel Fittings
This document is the property of N.I.O.C. Any unauthorised attempt to reproduce it, an any form, is strictly
prohibited.
ﺳﺎﻳﺖ ﻣﺮﺟﻊ ﺑﺎﺯﺭﺳﻲ ﻓﻨﻲ ﻭ ﻛﻨﺘﺮﻝ ﻛﻴﻔﻴﺖ
ASTM B584 Standard Specification for Copper Alloy Sand Castings for
General Applications
This document is the property of N.I.O.C. Any unauthorised attempt to reproduce it, an any form, is strictly
prohibited.
ﺳﺎﻳﺖ ﻣﺮﺟﻊ ﺑﺎﺯﺭﺳﻲ ﻓﻨﻲ ﻭ ﻛﻨﺘﺮﻝ ﻛﻴﻔﻴﺖ
ASTM D2122 Standard Test Method for Determ ining Dim ensions of
Thermoplastic Pipe and Fittings
ASTM D2393 Standard Test Method for Viscosity of Epoxy Resins and
Related Components
ASTM D2471 Standard Test Method for Gel Time and Peak Exothermic
Temperature of Reacting Thermosetting Resins
This document is the property of N.I.O.C. Any unauthorised attempt to reproduce it, an any form, is strictly
prohibited.
ﺳﺎﻳﺖ ﻣﺮﺟﻊ ﺑﺎﺯﺭﺳﻲ ﻓﻨﻲ ﻭ ﻛﻨﺘﺮﻝ ﻛﻴﻔﻴﺖ
ASTM E45 Standard Test Methods for Determ ining the Inclusion
Content of Steel
ASTM E92 Standard Test Method for Vick ers Hardness of Metallic
Materials
ASTM F36 Standard Test Method for Com pressibility and Recovery
of Gask et Materials
Others
DI N 2614 Cem ent Mortar Linings for Ductile Iron and Steel Pipes
and Fittings
This document is the property of N.I.O.C. Any unauthorised attempt to reproduce it, an any form, is strictly
prohibited.
ﺳﺎﻳﺖ ﻣﺮﺟﻊ ﺑﺎﺯﺭﺳﻲ ﻓﻨﻲ ﻭ ﻛﻨﺘﺮﻝ ﻛﻴﻔﻴﺖ
B S 1868 Steel Check Valve (Flanged and Butt W elding End) for
the Petroleum, Petrochemical and Allied Industries.
B S 1873 Steel Globe and Globe Stop and Check Valves (Flanged
and Butt W elding-Ends) for the Petroleum, Petrochem ical
and Allied Industries
B S E N 12449 Copper and Copper Alloys - Seam less, Round Tubes for
General Purposes
This document is the property of N.I.O.C. Any unauthorised attempt to reproduce it, an any form, is strictly
prohibited.
ﺳﺎﻳﺖ ﻣﺮﺟﻊ ﺑﺎﺯﺭﺳﻲ ﻓﻨﻲ ﻭ ﻛﻨﺘﺮﻝ ﻛﻴﻔﻴﺖ
NACE MR0175/ISO 15156 Petroleum and Natural Gas Industries Materials f or use in
H2S-Containing Environments in Oil and Gas production.
Loadi ng
ASCE/SEI 7-05 Minumum Design Loads for Buildings and Other Structure
Concrete Design
This document is the property of N.I.O.C. Any unauthorised attempt to reproduce it, an any form, is strictly
prohibited.
ﺳﺎﻳﺖ ﻣﺮﺟﻊ ﺑﺎﺯﺭﺳﻲ ﻓﻨﻲ ﻭ ﻛﻨﺘﺮﻝ ﻛﻴﻔﻴﺖ
PCA Notes on ACI 318-02 Building Code Requirem ents for Structural Concrete
Foundation
Roads design
Ov erseas Road Note 31 (Fourth Edition), Transport Research Laboratory, ―A guide to the
structural design of bitum en-surfaced roads in tropical and sub-tropical countriesǁ
A.A.S.H.T.O. standards
This document is the property of N.I.O.C. Any unauthorised attempt to reproduce it, an any form, is strictly
prohibited.
ﺳﺎﻳﺖ ﻣﺮﺟﻊ ﺑﺎﺯﺭﺳﻲ ﻓﻨﻲ ﻭ ﻛﻨﺘﺮﻝ ﻛﻴﻔﻴﺖ
ASTM A53 Standard Specification for Pipe, Steel, Black & Hot Dipped,
ASTM A307 Standard Specification for Carbon Steel Bolts and Studs,
ASTM C 192/192M Practice for Mak ing and Curing Concrete Test Specim ens
in t h e L a b o r a t o r y
This document is the property of N.I.O.C. Any unauthorised attempt to reproduce it, an any form, is strictly
prohibited.
ﺳﺎﻳﺖ ﻣﺮﺟﻊ ﺑﺎﺯﺭﺳﻲ ﻓﻨﻲ ﻭ ﻛﻨﺘﺮﻝ ﻛﻴﻔﻴﺖ
ASCE/SEI 7-05 Minimum Design Loads for Buildings and Other Structure
PCA Notes on ACI 318-02 Building Code Requirem ents for Structural Concrete
ASTM A53 Standard Specification for Pipe, Steel, Black & Hot Dipped,
ASTM A307 Standard Specification for Carbon Steel Bolts and Studs,
This document is the property of N.I.O.C. Any unauthorised attempt to reproduce it, an any form, is strictly
prohibited.
ﺳﺎﻳﺖ ﻣﺮﺟﻊ ﺑﺎﺯﺭﺳﻲ ﻓﻨﻲ ﻭ ﻛﻨﺘﺮﻝ ﻛﻴﻔﻴﺖ
ASTM A 496/496M Standard Specification for Steel W ire, Deform ed, for
Concrete Reinforcem ent
ASTM A 700 Practices for Pack aging, Mark ing, and Loading Methods
for Steel Products for Shipm ent
ASTM C 684 Test Method for Mak ing, Accelerated Curing, and Testing
of Concrete Compression Test Specim ens
ASTM C 192/192M Practice for Mak ing and Curing Concrete Test Specim ens
in t h e L a b o r a t o r y
3.10.4 M aterials
A. S. T . M St a n d a r d s o r e q u a l
3.10.5 Insulati on
3.11 HVAC
This document is the property of N.I.O.C. Any unauthorised attempt to reproduce it, an any form, is strictly
prohibited.
ﺳﺎﻳﺖ ﻣﺮﺟﻊ ﺑﺎﺯﺭﺳﻲ ﻓﻨﻲ ﻭ ﻛﻨﺘﺮﻝ ﻛﻴﻔﻴﺖ
- Fundamental
- Refrigeration
UK Heating Ventilation Contractor Association (HVAC) Specification for Sheet Metal Duct
W ork
BS 476 Part 7 Method of Test to Determ ine the Classification of the Surface
Spread of Flame of Product
3.12 Electrical
The latest edition of the following standards and codes shall be applied where applicable:
1- The institute of petroleum m odel code of safe practice, part 1 electrical, and part 15 area
classification code for petroleum installations.
This document is the property of N.I.O.C. Any unauthorised attempt to reproduce it, an any form, is strictly
prohibited.
ﺳﺎﻳﺖ ﻣﺮﺟﻊ ﺑﺎﺯﺭﺳﻲ ﻓﻨﻲ ﻭ ﻛﻨﺘﺮﻝ ﻛﻴﻔﻴﺖ
IE C 6 0 1 4 6 Semi-conductor convectors
IE C 6 0 2 5 5 Electrical relays
IE C 6 0 2 8 9 Reactors
IE C 6 0 2 9 2 LV m otor starters
This document is the property of N.I.O.C. Any unauthorised attempt to reproduce it, an any form, is strictly
prohibited.
ﺳﺎﻳﺖ ﻣﺮﺟﻊ ﺑﺎﺯﺭﺳﻲ ﻓﻨﻲ ﻭ ﻛﻨﺘﺮﻝ ﻛﻴﻔﻴﺖ
IEC 60055-2 Paper insulated m etal sheathed cables for rated v oltage
up to 18/30Kv
IE C 6 0 0 3 8 Standard voltage
This document is the property of N.I.O.C. Any unauthorised attempt to reproduce it, an any form, is strictly
prohibited.
ﺳﺎﻳﺖ ﻣﺮﺟﻊ ﺑﺎﺯﺭﺳﻲ ﻓﻨﻲ ﻭ ﻛﻨﺘﺮﻝ ﻛﻴﻔﻴﺖ
IEC 61800-2 Adj ustable speed electrical power drive systems part 2
IE C 6 0 3 3 7 Control switches
BS EN 50 021 Ty p e N p r o t e c t i o n
This document is the property of N.I.O.C. Any unauthorised attempt to reproduce it, an any form, is
strictly prohibited.
ﺳﺎﻳﺖ ﻣﺮﺟﻊ ﺑﺎﺯﺭﺳﻲ ﻓﻨﻲ ﻭ ﻛﻨﺘﺮﻝ ﻛﻴﻔﻴﺖ
Others
A PI 6 5 1 Cathodic Protection
This document is the property of N.I.O.C. Any unauthorised attempt to reproduce it, an any form, is strictly
prohibited.
ﺳﺎﻳﺖ ﻣﺮﺟﻊ ﺑﺎﺯﺭﺳﻲ ﻓﻨﻲ ﻭ ﻛﻨﺘﺮﻝ ﻛﻴﻔﻴﺖ
A PI R P 5 5 2 Transmission System
A PI R P 5 5 5 Process Analysers
This document is the property of N.I.O.C. Any unauthorised attempt to reproduce it, an any form, is strictly
prohibited.
ﺳﺎﻳﺖ ﻣﺮﺟﻊ ﺑﺎﺯﺭﺳﻲ ﻓﻨﻲ ﻭ ﻛﻨﺘﺮﻝ ﻛﻴﻔﻴﺖ
Installation
ASME, Div. 1 Flanged Rating when Tem perature Exceeds the Lim its of
Sect. VIII, ap. 2 ANSI B 16-5
ASME, Div. 1 Hydraulic Test for Safety Relief Valv e Sect. VIIII
IEC 60092.353 Single & Multicore Cables with Extruded Solid Insulation
for Rated Voltage 0.6/1.0 KV
IEC 60245-1 to 4 Rubber Insulated Conductors & Cables, Nom inal Voltage
450/750 Volts
This document is the property of N.I.O.C. Any unauthorised attempt to reproduce it, an any form, is strictly
prohibited.
ﺳﺎﻳﺖ ﻣﺮﺟﻊ ﺑﺎﺯﺭﺳﻲ ﻓﻨﻲ ﻭ ﻛﻨﺘﺮﻝ ﻛﻴﻔﻴﺖ
IE C 6 0 5 8 4 Thermocouples
IE C 6 1 1 3 1 Programmable Controllers
This document is the property of N.I.O.C. Any unauthorised attempt to reproduce it, an any form, is strictly
prohibited.
ﺳﺎﻳﺖ ﻣﺮﺟﻊ ﺑﺎﺯﺭﺳﻲ ﻓﻨﻲ ﻭ ﻛﻨﺘﺮﻝ ﻛﻴﻔﻴﺖ
ISA S5.5 Graphic Sym bols for Process display (Version: 1986)
ISA S75.03 / ASME B16.10 Uniform Face to Face Dim ensions for Flanged Globe
Style Control Valve Bodies
ISA S75.012 Face to Face dim ensions for Socket W eld-end and
Screwed-end Globe-Style control Valves
ISA S75.014 Face to Face Dim ensions for Buttweld End gold style
control valv es
ISA RP 18.1 Al a r m a n d S e q u e n c e s
This document is the property of N.I.O.C. Any unauthorised attempt to reproduce it, an any form, is strictly
prohibited.
ﺳﺎﻳﺖ ﻣﺮﺟﻊ ﺑﺎﺯﺭﺳﻲ ﻓﻨﻲ ﻭ ﻛﻨﺘﺮﻝ ﻛﻴﻔﻴﺖ
P a ge : 37 of 50
British Standards
BS 5445 PT5 Com ponents of Autom atic Fire Detection Systems – Heat
Sensitive Detectors-Point Detectors Containing a Static
El e m e n t
This document is the property of N.I.O.C. Any unauthorised attempt to reproduce it, an any form, is strictly
prohibited.
ﺳﺎﻳﺖ ﻣﺮﺟﻊ ﺑﺎﺯﺭﺳﻲ ﻓﻨﻲ ﻭ ﻛﻨﺘﺮﻝ ﻛﻴﻔﻴﺖ
E E M UA
This document is the property of N.I.O.C. Any unauthorised attempt to reproduce it, an any form, is strictly
prohibited.
ﺳﺎﻳﺖ ﻣﺮﺟﻊ ﺑﺎﺯﺭﺳﻲ ﻓﻨﻲ ﻭ ﻛﻨﺘﺮﻝ ﻛﻴﻔﻴﺖ
DNV
MI L
Others
This document is the property of N.I.O.C. Any unauthorised attempt to reproduce it, an any form, is strictly
prohibited.
ﺳﺎﻳﺖ ﻣﺮﺟﻊ ﺑﺎﺯﺭﺳﻲ ﻓﻨﻲ ﻭ ﻛﻨﺘﺮﻝ ﻛﻴﻔﻴﺖ
EIA RS 232/422/485 Interface between Data Term inal Equipm ent and Data
Com munication Equipment Employing serial Binary Data
General
This document is the property of N.I.O.C. Any unauthorised attempt to reproduce it, an any form, is strictly
prohibited.
ﺳﺎﻳﺖ ﻣﺮﺟﻊ ﺑﺎﺯﺭﺳﻲ ﻓﻨﻲ ﻭ ﻛﻨﺘﺮﻝ ﻛﻴﻔﻴﺖ
N FP A 5 9 A S t a n d a r d f o r P r o d u c t i o n , S t o r a g e a n d H a n d li n g o f L P G
N FP A 7 2 N a t i o n a l Fi r e A l a r m C o d e
This document is the property of N.I.O.C. Any unauthorised attempt to reproduce it, an any form, is strictly
prohibited.
ﺳﺎﻳﺖ ﻣﺮﺟﻊ ﺑﺎﺯﺭﺳﻲ ﻓﻨﻲ ﻭ ﻛﻨﺘﺮﻝ ﻛﻴﻔﻴﺖ
N FP A 1 9 6 1 Fire Hose
3.15 N oi s e C o nt r ol
This document is the property of N.I.O.C. Any unauthorised attempt to reproduce it, an any form, is strictly
prohibited.
ﺳﺎﻳﺖ ﻣﺮﺟﻊ ﺑﺎﺯﺭﺳﻲ ﻓﻨﻲ ﻭ ﻛﻨﺘﺮﻝ ﻛﻴﻔﻴﺖ
3.16 Painting
SP 6 C o m m e r c i a l Bl a s t C l e a n i n g
SP 8 P ic k l i n g
This document is the property of N.I.O.C. Any unauthorised attempt to reproduce it, an any form, is strictly
prohibited.
ﺳﺎﻳﺖ ﻣﺮﺟﻊ ﺑﺎﺯﺭﺳﻲ ﻓﻨﻲ ﻭ ﻛﻨﺘﺮﻝ ﻛﻴﻔﻴﺖ
Others
3.17 Insulation
ASTM A167 Stainless Steel and Heat Resisting Chrom ium – Nickel
Steel Plate, Sheet and Strip
This document is the property of N.I.O.C. Any unauthorised attempt to reproduce it, an any form, is strictly
prohibited.
ﺳﺎﻳﺖ ﻣﺮﺟﻊ ﺑﺎﺯﺭﺳﻲ ﻓﻨﻲ ﻭ ﻛﻨﺘﺮﻝ ﻛﻴﻔﻴﺖ
ASTM C547 Mineral Fibre Blanket Insulation & Blanket Type Pipe
Insulation (metal meshcovered)
ASTM C795 W icking Type Therm al Insulation for use over austenitic
stainless steel
ASTM D2856 Open Cell Content of Rigid Cellular Plastics by the Air
Pycnom eter
This document is the property of N.I.O.C. Any unauthorised attempt to reproduce it, an any form, is strictly
prohibited.
ﺳﺎﻳﺖ ﻣﺮﺟﻊ ﺑﺎﺯﺭﺳﻲ ﻓﻨﻲ ﻭ ﻛﻨﺘﺮﻝ ﻛﻴﻔﻴﺖ
B S 5970 Therm al Insulation of Pipe W ork and Equipm ent (in the
tem perature range of -100°C to +870°C
3.18 Fireproofing
(Underwriter Laboratories)
NA CE
NACE MR0175/ISO 15156-1/2/3: 2001 (E): Petroleum and natural gas industries-Materials
for use in H2S-containing environm ents in oil and gas production.
EFC Publication No.16: Guidelines on Materials Requirem ents for Carbon and Low
Alloy Steels for H2S-Containing Environm ents in Oil and Gas Production.
EFC Publication No.17: Corrosion Resistant Alloys for Oil and Gas Production:
Guidance on General Requirem ents and Test Methods for H2S Service.
European Norms
British Standards
This document is the property of N.I.O.C. Any unauthorised attempt to reproduce it, an any form, is strictly
prohibited.
ﺳﺎﻳﺖ ﻣﺮﺟﻊ ﺑﺎﺯﺭﺳﻲ ﻓﻨﻲ ﻭ ﻛﻨﺘﺮﻝ ﻛﻴﻔﻴﺖ
BS EN ISO 9934-1: Non destructive testing. Magnetic particle testing .General Principles.
BS EN 10160: Ultrasonic testing of steel flat product of thick ness equal or grater than 6mm
(reflection method).
BS EN 1714: Non destructiv e testing of welded j oints. Ultrasonic testing of welded j oints
Section II
E 94 G u i d e f o r R a d i o g r a p h ic T e s t i n g
This document is the property of N.I.O.C. Any unauthorised attempt to reproduce it, an any form, is strictly
prohibited.
ﺳﺎﻳﺖ ﻣﺮﺟﻊ ﺑﺎﺯﺭﺳﻲ ﻓﻨﻲ ﻭ ﻛﻨﺘﺮﻝ ﻛﻴﻔﻴﺖ
API Std 1104 Standard for W elding Pipelines and Related Facilities
3.20 Telecommunication
W here there are no equivalent Iranian standards, the appropriate International and
European standards shall be applied to the Telecom m unications system Design. These
shall include, but not be lim ited to, all applicable sections of :
♦ I E E , I E E E , I S O a n d I E C S t a n d a r d s , TI A / E I A
♦ IMO Regulations
♦ ICAO Regulations
♦ CENELEC Standards
This document is the property of N.I.O.C. Any unauthorised attempt to reproduce it, an any form, is strictly
prohibited.