Datasheet - Design Requirement C-84524-RW-PP0-DSR-ST-43-0001 Rev
Process Datasheet of Flare KO Drum
ConocoPhillips (Grissik) Ltd.
Rev
1 BASIS AND ASSUMPTION
2
3 1 Pumping out duration from start - stop of pump 1 hr (Note 1)
4 2 Particle diameter 300 micron (Note 2)
5 3 L/D 2
6 6 Liquid Hold-up time required between LLL - HLL 30 minute(s) (Note 2)
7 7 Total Length required = Required length + additional space of nozzle size (= 1.5 ID in + 1.5 ID out)
8 5 Nozzle Size Criteria, ρv2 < 50000 or one size bigger than flare line size whichever greater (Note 3)
9 4 Liquid Level Setting Criteria 1 min or 6 inch
10
11 PROPERTIES DATA
12
13 Properties data are taken from "All PVs flaring Case"
14
15 FLUID DATA UNIT GAS LIQUID
16 Pressure psig 23.6 23.6
17 Temperature F 77.60 77.60
18 Flowrate (Note 4) MMscfd 66.38 6.44
19 lb/hr 155543 30064
20 Design Margin % 10 10
21 Design flowrate lb/hr 171097.3 33070.4
22 Molecular Weight 21.34 42.53
23 Mass Density lb/ft3 0.14 64.93
24 Viscosity cp 0.0116 3.79
25
26
27 SKETCH 5791.2 mm
28
29 inlet outlet
30
31
32 HHLL : 1066.8 mm
33 HLL/LAG Pump Start : 914.4 mm
34 NLL/LEAD Pump Start : 762 mm
35 2895.6 mm LAG Pump Stop : 609.6 mm
36 LLL/LEAD Pump Stop : 457.2 mm
37 LLLL : 304.8 mm
38
39
40
41 CALCULATION
42 Liquid Hold-Time Required = 30 minute between LLL & HLL
43 Vapor flow rate = 77608 kg/hr
44 = 34607 m3/hr
45 Vapor Density, ρv = 2.24 kg/m3
46 Vapor Viscosity, μ = 0.012 cP
47 Liquid Flowrate = 15000.5 kg/hr
48 = 14.4 m3/hr
49 Liquid Density, ρL = 1040.081 kg/m3
50 KO Drum Pumps capacity = 24 Usgpm
51 = 5.5 m3/hr
52 Inlet Stream mix Density = 2.7 kg/m3
53
54 Determination fo drag coefficient (per API RP 521)
55
56 C(Re)2
57
58
59
60
Datasheet - Design Requirement C-84524-RW-PP0-DSR-ST-43-0001 Rev
Process Datasheet of Flare KO Drum
ConocoPhillips (Grissik) Ltd.
Rev
1 particle diameter, Dp = 300 microns
2 = 0.0003 m
3 C(Re)2 = 6071
4 Drag coefficient, C = 1.24
5
6
7 Droplet Velocity
8
9
10 Droplet Velocity = 1.20 m/s
11 Drum Diameter = 2896 mm = 9.5 ft
12 Drum Length = 5791 mm = 19 ft
13 L/D = 2
14 Drum cross section area = 6.59 m2
15 Total Cylinder Volume = 38.14 m3
16 Total Heads Volume = 6.35 m3
17 Total Vessel volume = 44.49 m3
18
19 Liquid Levels partial vol, m3
Liquid area
20 reference level, in level, mm m2 cylinder Heads total vol m3 Vol, m3
21 Bottom 0 0 0 0 0 0 0
22 LLLL 12 305 0.37 2.14 0.20 2.34 2.34
23 LEAD Pump stop 18 457 0.67 3.86 0.43 4.29 4.29
24 LAG Pump stop 24 610 1.01 5.84 0.73 6.57 6.57
25 LEAD Pump start 30 762 1.38 8.01 1.09 9.10 9.10
26 LAG Pump start 36 914 1.78 10.33 1.50 11.83 11.83
27 HHLL 42 1067 2.20 12.75 1.95 14.71 14.71
28
29
30 Criteria Calculation Status
31 hold up time hold up time hold up time
height (in) height (in) height (in)
32 (min) (min) (min)
Page 6 of 8