Anda di halaman 1dari 3

Paper max ∆E76 ≤ 3.0 0.

0 P HEATSET NEWS PROOF


max ∆E76 ≤ 5.0 0.0 P CGATS21 CRPC2
Primaries
max ∆H ≤ 2.5 0.0 P M1 - SCCA OFF

P
ISO12647-7:2013
Overprints max ∆E76 ≤ 6.0 0.0 P
Grays
avg w∆Ch ≤ 1.5
max w∆Ch ≤ 3.0
0.0
0.0
P
P
Passed
avg w∆L* ≤ 1.5 0.0 P 5/8/2019 10:45
NPDC
max w∆L* ≤ 3.0 0.0 P This software is provided free of
charge as a demonstration tool only.
avg ∆E76 ≤ 3.0 0.0 P Its use does not constitute a warranty
Overall or certification by IDEAlliance as to the
max ∆E76 ≤ 6.0 0.0 P accuracy or quality of a proof.
Before using this tool, please READ THIS NOTICE
Legal Notice: This product is intended for demonstration and quality control only and does not constitute a part of any officia
software and IDEAlliance accept no responsibility for damages resulting from the use of this product and make no warranty
not limited to, any implied warranty of merchantability or fitness for a particular purpose. This software is provided "AS IS", a
software may be freely used and distributed for noncommercial uses only. Alteration or incorporation into commercial produ
prohibited.

Instructions (i1Profiler)
Initial installation
• Launch i1Profiler
• Select the 'Advanced' radio button
• Select 'Measure Reference Chart' from the 'Workflow Selector'
• Right-click anywhere in the 'Assets' pane and select 'Show in Finder' (Open Containing Folder in Windows)
• Put the Workflow (.rwxf) file(s) you intend to use in the folder that appeared from the previous step
• Click the 'Refresh Assets' (circular arrow) button at the top of the Assets pane

Step 1 - M• Launch i1Profiler if it isn't already running


• Select 'Measure Reference Chart' from the 'Workflow Selector'
• Double-click a 'Saved Workflow' you installed during the Initial Installation from the 'Assets' list
• Make sure your instrument is connected and choose the 'Measurement Mode'
• Click 'Calibrate' and follow the instructions to measure the chart
• Click 'Save' to save the measurement data
• Select 'i1Profiler CGATS Custom' as the file type where you want it saved
• Enter an appropriate name for the measurement data file and click 'Save'
• Select only the L*a*b* checkbox and click 'OK'

Step 2 - Im• Open Proof Verifier in Excel


• Open the saved .txt data file from Step 1 in Excel
• Select the Lab data in the .txt file and copy it
• Select the 'Pass-Fail' worksheet (tab) at the bottom of the Proof Verifier spreadsheet
• Select the 'Strip Format' 2009 or 2013
• Select the data type in the 'Select appropriate data type:' pop-down menu
• Paste the copied data into upper left cell where it says, 'Paste measured values'

Step 3 - V • The 'Use SCCA' caculates new 'Reference Data' based on the measured paper value
• The 'Primary, Overprint, and Gray Values' table shows
the ∆E, ∆H, ∆Ch, and ∆L* for each color in the table
• The 'Maximum Patches' table shows which patches (% value)
have the highest ∆E
• The 'Pass-Fail box shows if the proof Passed or Failed
for the set tolerances

Note, ∆Ch is the difference between two colors, ignoring their lightness difference. This is very useful for measuring gray bal
Points on a gray scale should always be expressed in terms of ∆Ch and ∆L* together. ∆L* monitors tonality, ∆Ch monitors g
onstitute a part of any official certification program of IDEAlliance. The authors of this
duct and make no warranty or representation, either express or implied, including but
tware is provided "AS IS", and you, its user, assume all risks when using it. This
ation into commercial products without express written consent of its authors is strictly

ng Folder in Windows)
previous step

seful for measuring gray balance error.


ors tonality, ∆Ch monitors gray balance.

Anda mungkin juga menyukai