Specifications, designs and other content appearing in this brochure are current as of April 2017 but subject to change without notice.
04/17
Product Lineup 1 phase 3 phase
NEW
RZR71LVVM RZR100LVVM
Page 16 RZR100MYM
Outdoor unit
OUTDOOR UNIT
NEW
NEW RZR125MVMG
RZR71LVVMG RZR100MVMG
2 3
OPTIONAL
Outdoor unit operating
sound can be reduced
by 4dB(A).
CEILING MOUNTED CASSETTE TYPE Round Flow
Cassette Air Conditioner with 360° Compact Body for Quick & Easy Drain Pump is Equipped as
Installation in Tight Ceiling Standard Accessory with 850 mm
Uniform Airflow sets The Standard
(50LU-71LU) Lift.
256 mm *1 266 mm *2
850 mm
175 mm
*1 298 mm high with 100–140 KA/LU
*2 308 mm high with 100–140 KA/LU
Space. COP
Indoor Colour Decoration panel
W/W 4.85 4.29 3.78 3.79
Fresh white
3.35 3.60 2.90 2.49
unit Airflow rate (H/M/L) m3/min 21/-/13.5 32/26/20 33/28/22.5 32/26/20 33/28/22.5
Because air flows out from corner outlets, comfort Sound level (HH/H/M/L)3 dB(A) (-/35/-/28) (43/37.5/-/32) (44/39/-/34) (-/43/37.5/32 (-/44/39/34) (-/44/40/36)
spreads more widely. Dimensions
(HXWXD)
Unit mm 256X840X840 298X840X840
Decoration panel mm 50X950X950
Machine Unit kg 21 24
weight
Typical flow patterns Decoration panel kg 5.5
Certified Operation range Cooling °CWB 14 to 25
Outdoor Colour Ivory white
There are a total of 23 flow patterns. unit Compressor Type Hermetically sealed swing type Hermetically sealed swing type
Motor output kW 1.12 1.35 1.76 2.03 2.03 1.92 1.92
L-shaped Opposite Refrigerant charge (R-410A) 1.6 1.9 1.9 1.9
All-round flow 3-way flow 2-way flow 2-way flow kg (Charged for 30 m) (Charged for 30 m) (Charged for 30 m) (Charged for 30 m)
Sound level3 Cooling dB(A) 48 49 52 49 52 54
Night quiet mode dB(A) 44 45 45
Dimensions (HXWXD) mm 595X845X300 990X940X320 990X940X320
Machine weight kg 43 65 73
(E.g., installed in (E.g., installed (E.g., installed in (E.g., installed in
10 11
DUCT CONNECTION MIDDLE STATIC PRESSURE TYPE
Flexibility SPECIFICATIONS
With a height of only 245 mm, installation is possible 50 60 71 100 125
even in buildings with narrow ceiling spaces Model Indoor unit FBQ50EVE FBQ60EVE FBQ71EVE FBQ100EVE FBQ125EVE
Name RZR50LVVM RZR60LVVM RZR71LVVMG RZR100MVMG RZR125MVMG
Outdoor unit
850mm
Power supply Indoor unit 1 Phase, 220–240 V, 50 Hz
Outdoor unit 3 Phase, 380–415 V, 50 Hz
Cooling capacity1,2 kW 10.0 (5.0-11.2) 12.5 (5.7-14.0) 14.0 (6.2-15.4)
Rated (Min. - Max.) Btu/h 34,100 (17,100-28,200) 42,700 (19,500-47,800) 47,800 (21,200-52,600)
Power consumption Cooling1 kW 2.82 4.58 5.85
COP W/W 3.55 2.73 2.39
Fan Airflow rate (H/M/L) m /min
3
38/35.5/33 36/30.5/25
Indoor
unit External static pressure3 Pa Rated 50 (50-150)
DC Fan motor and DC drain pump are utilised to Outdoor Sound pressure
level4
Cooling dB(A) 49 52 54
unit Night quiet mode dB(A) 45
improve energy efficiency Dimensions (HXWXD) mm 990X940X320
Machine weight (outdoor) kg 73
Piping Liquid mm o/ 9.5 (Flare)
connection Gas mm o/ 15.9 (Flare)
Clean
Indoor unit mm VP25 (I.Do/ 25×O.Do/ 32)
Drain
Outdoor unit mm o/ 26 (Hole)
Max interunit piping length m 50 (Equivalent length 70m)
Silver ion anti-bacterial drain pan Heat insulation Both liquid and gas piping
Position of drain pan inspection opening has Using a DC fan motor, the external static pressure
been modified for easier inspection work OPTIONS
can be controlled to within a range of 50 Pa to 150 Pa Kit name
Name of option Remark
Drain pan maintenance check window FBQ50EVE FBQ60EVE FBQ71EVE FBQ100EVE FBQ125EVE FBQ140EVE
Adjustable external static pressure Remote controller Wireless type Cooling only BRC4C66
This makes it possible to inspect for drain pan dirt and to Wired type1 BRC1C61
confirm drainage during installation without the use of Navigation Remote Controller1 BRC1E62
50 Pa 150 Pa
Adaptor for wiring KRP1C64
tools.
Wiring adaptor for electrical appendices(2) KRP4AA51
Remote sensor KRCS01-4B
Mounting plate for adaptor PCB.2,3,4 KRP4A98
Inspection opening for Central remote controller5 DCS302CA61
drain pan Unified ON/OFF controller5 DCS301BA61
Set to low static Set to high static pressure for
pressure when ducts advanced needs such as when Schedule timer5 DST301BA61
Drain pan maintenance
are short. using dampers and long ducts. intelligent Touch Controller5 DCS601C51
check window
1
Note: Wiring for wired remote controller to be procured locally. 4
Only one mounting plate can be installed for each indoor unit.
2 5
Mounting plate is necessary for each adaptor marked . The indoor unit is equipped standardly with the interface adaptor for SkyAir series.
Comfort airflow is achieved in accordance with conditions such as 3
Up to 2 adaptors can be fixed for each mounting plate. The Interface adaptor for SkyAir series is not necessary for this indoor unit since it is equipped as standard.
Easy maintenance because the drain pan can be duct length.
removed
12 13
CEILING SUSPENDED TYPE
Benefits of DA series
COP W/W 3.60 3.56 2.84
Colour White
Indoor
Airflow rate (H/L) m3/min 17/-/14
unit
Sound level (H/L)2 dB(A) 39/-/35
Dimensions (HXWXD) mm 195X1,160X680
The technology of the DC fan motor, wide sirocco fan, Machine weight kg 27
and large heat exchanger combine for greater airflow Certified operation range °CWB 14 to 25
and quiet operation. Outdoor
Colour Ivory white
unit Compressor Type Hermetically sealed swing type
High/Middle/Low : 46/42/38 dB(A) Motor output kW 1.12 1.35 1.76
Refrigerant charge (R-410A) kg 1.6 (Charged for 30 m)
Sophisticated design Sound level Cooling
3 dB(A) 48
Night quiet mode dB(A) 44
Flap neatly closes when Dimensions (HXWXD) mm 595X845X300
not in use. Machine weight kg 43
Certified operation range °CDB 10 to 46
Fresh white colour. Piping Liquid (Flare) mm o/ 9.5
connections Gas (Flare) mm o/ 15.9
Drain Indoor unit mm VP20 (I.D o/ 20XO.D o/ 26)
Installable on ceilings 4.3 m high Outdoor unit mm o/ 26.0 (Hole)
Max. interunit piping length m 50 (Equivalent length 70)
Max. installation level difference m 30
Heat insulation Both liquid and gas piping
Comfortable
Indoor Colour white Light Ivory
unit Airflow rate (H/M/L) m3/min 24/-/20 30/-/25 28/24/20 31/27/23 34/29/24
Sound level (H/M/L)2 dB(A) 42/-/37 44/-/39 42/38/34 44/41/37 46/42/38
Auto swing (up and down) and louvers (left and right Dimensions (HXWXD) mm 195X1,400X680 195X1,590X680 235X1,590X690
Machine weight kg 32 35 38
by hand) bring comfort to the room Certified operation range °CWB 14 to 25
Colour Ivory white
Outdoor
Louver manually adjusts unit Compressor Type Hermetically sealed swing type Hermetically sealed scroll type Hermetically sealed swing type
Easy Maintenance
Outdoor unit mm o/ 26.0 (Hole)
Max. interunit piping length m 50 (Equivalent length 70)
Max. installation level difference m 30
Long-life filter (standard) requires no maintenance for
Quiet Operation at 32** dB(A)
Heat insulation Both liquid and gas piping
about 1 year* Note :
1
Rated cooling capacities are based on the following conditions: Indoor temp., 27°CDB, 19.0°CWB; outdoor temp. 35°CDB, 24°CWB. Equiv. refrigeration piping, 7.5 m (horizontal).
**Selected models only 2
The filter is washable and reused after 1 year. Capacities are net, including a deduction for cooling for indoor fan motor heat.
3
Anechoic chamber conversion value, measured according to JIS parameters and criteria. During operation these values are somewhat higher owing to ambient conditions.
3
* For dust concentration of 0.15 mg/m
Uses quiet stream fan and other quiet Two time settings (2500 hrs and 1250 hrs) are available to match the installation
technologies.
environment. Maintenance time warning is displayed on the remote controller OPTIONS
(filter sign).
(FHQ50-125BV) Kit name
Easy-clean, flat surfaces Name of option Remark
FHQ50/60BVV1G FHQ71BVV1B FHQ100BVV1B FHQ125BVV1B FHQ100/125/140DAVMA
Replacement long-life filter Resin net KAF501DA80 KAF501DA112 KAF501DA160 KAFP501A160
Drain pump kit KDU50N125VE KDU50P140VE
incorporated
Navigation Remote Controller Wired type1 BRC1E62
Wiring adaptor for electrical appendices2 KRP4AA52
Comfortable
Machine weight kg 13 17
Certified Operation range °CWB 14 to 25
Colour Ivory white
Outdoor
• Auto swing unit Compressor Type Hermetically sealed swing type
Motor output kW 1.76 2.03 1.92
Refrigerant charge (R-410A) kg 1.6 (Charged for 30 m) 3.35 (Charged for 30 m) 1.9 (Charged for 30 m)
Wide-angle louvers Sound level3 Cooling dB(A) 48 49
Night quiet mode dB(A) 44 45
(by hand) Dimensions (HXWXD) mm 595X845X300 900X940X320
Soft material louver Machine weight kg 43 78 73
Certified Operation range °CDB 21 to 46
bends airflow over mm o/ 9.5
Piping Liquid (Flare)
a wider area connections Gas (Flare) mm o/ 15.9
Drain Indoor unit mm VP13 (I.D o/ 13 X O.D o/ 18)
Outdoor unit mm o/ 26.0 (Hole)
Max. interunit piping length m 50 (Equivalent length 70m)
Auto-swing 5-level air direction setting Max. installation level difference m 30
Heat insulation Both liquid and gas piping
Note :
1
Rated cooling capacities are based on the following conditions: Indoor temp., 27°CDB, 19.0°CWB; outdoor temp. 35°CDB, 24°CWB. Equiv. refrigeration piping, 7.5 m (horizontal).
2
Capacities are net, including a deduction for cooling for indoor fan motor heat.
3
Anechoic chamber conversion value, measured according to JIS parameters and criteria. During operation these values are somewhat higher owing to ambient conditions.
Gettable to 5
different levels
OPTIONS
Kit name
Name of option Remark
FAQ71CVEA FAQ100CVEA
Drain-up kit K-KDU572EVE
Remote controller Wireless type Cooling only BRC7EB519
Wired type1 BRC1C61
Navigation Remote Controller Wired type1 BRC1E62
• Switchable fan speed : High / Middle / Low Wiring adaptor for electrical appendices KRP4AA51
Installation box for adaptor PCB KRP4AA93
Compact & Sophisticated Design • Auto airflow rate (When BRC1E62 is used) Note: 1Wiring for wired remote controller to be procured locally.
Indoor unit
Drain pump kit
16 17
FLOOR STANDING TYPE
Control
Sound level3 Cooling dB(A) 48 49 50 49 52 54
Night quiet mode dB(A) 44 45 45
Dimensions (HXWXD) mm 595X845X300 990X940X320 1,170X900X320 990X940X320
Note :
1 Rated cooling capacities are based on the following conditions: Suction temp., 27°CDB, 19.0°CWB; outdoor temp. 35°CDB, 24°CWB. Equiv. refrigeration piping, 7.5 m (horizontal)
2
Capacities are net, including a deduction for cooling for indoor fan motor heat.
3
Anechoic chamber conversion value, measured according to JIS parameters and criteria. During operation these values are somewhat higher owing to ambient conditions.
Pattern 2 Swing on the left side Pattern 3 Swing on the right side
OPTIONS
Kit name
Name of option Remark
FVQ50CVE FVQ60CVE FVQ71CVEB FVQ100CVEB FVQ125CVEB FVQ140CVEB
Energy Saving
• A DC fan motor improves efficiency. Long-Life Filter Lasts about
1 year* Maintenance not required
*For dust concentration of 0.15 mg/m3
18 19
Functions
CEILING MOUNTED CASSETTE TYPE DUCT CONNECTION MIDDLE and CEILING SUSPENDED TYPE WALL MOUNTED TYPE FLOOR STANDING TYPE
Round Flow HIGH STATIC PRESSURE TYPE
Auto-restart
Control by 2 remote controllers
Group control by 1 remote controller
Control External command control *8 *8 *8 *8 *8 *8 *8
features *8 BV series
Central remote control needs option
Interlock control with Heat Reclaim Ventilator
DIII-NET communication standard Only for DA series
High-efficiency filter
Options Ultra long-life filter
Fresh air intake kit Only for DA series
Others Anti corrosion treated heat exchangers *3 *10 *10 *10 *10
Note: *1 : Applicable when BRC1E62 is used *3 : For outdoor units *5 : Applicable for FVQ50-100 *7 : Installable on max. 4.3 m high ceiling *9 : Applicable for 60/71 class indoor unit
*2 : Applicable when wired remote controller is used *4 : Applicable when BRC1C61 is used *6 : Installable on max. 3.5 m (50-71) *8 : Option *10 : Applicable for RZR50-71M, RZR-LV and RZR-LU
and 4.3 cm.(100-140 ) high ceiling
20 21
Work and Servicing
Drain pump mechanism Ceiling soiling prevention function
Comfort Steeper gradient realises more Daikin's innovative air discharge mechanism keeps airflow
efficient condensate drainage. away from the ceiling. Ceiling cleaning is less frequently
Auto-swing Programme "Dry" High-lift is especially useful for required.
Delivers comfortable The air flow direction can be Dehumidification is microprocessor controlled to prevent long lengths of drain piping.
air-conditioning to all areas, near fixed at your desited angle abrupt and uncomfortable changes in air temperature. Useful Low gas pressure detection
to and far from the by the remote controller. for reducing uncomfortable humidity without uncomfortable
air-conditioner. cooling of the room. Pre charged for up to 30 metres Insufficient gas charging is normally hard to detect. During
post-installation trials and regular inspection procedures, the
Swing pattern selection If refrigerant piping length does not exceed 30 m, there is no refrigerant level is monitored by microprocessor to maintain
High-ceiling application need for on-site gas charging. proper gas pressure. Reliability is assured and maintenance
You can freely set air discharge setting by remote controller.
*Applicable to RZR50-140. and inspection can be carried out more quickly.
Delivers air-conditioning comfort all
(1) Air direction (2) Air direction in (3) Air direction in RXS50FA/60F/71F,RKS25A/35A : 10 m
the way down to the floor in
in standard
setting
draft prevention
setting
ceiling soiling
prevention setting
air-conditioning zones with high Emergency operation
ceilings. Long-life filter If there is a malfunction elsewhere in the system, the fan or
Maintenance is not required for one year*. compressor can still be operated.
The filter is washable and can be reused.
Note: When units are installed on high ceilings, depending on the model,
various restrictions concerning maximum height, air discharge direction,
*For dust concentration of 0.15 mg/m3 Self diagnosis function
and choice of options may apply.
The operating parameters of indoor and outdoor units, and
Independent up-and-down airflow Filter sign sensor data at critical locations throughout the system, are
Independently adjust (manually) the eight horizontal blade Two selectable temperature-sensors The filter sign warns you when it is time to clean the filter. constantly monitored using a microcomputer. To facilitate
louvers in both up and down directions to achieve an airflow that Temperature-sensors are included in the indoor unit and *When using a wired remote controller the sign is displayed in the LCD. quick response in the event of a malfunction, a message
reduces uneven room temperature. optional wired remote controller. Temperature sensing closer When using a wireless remote controller the filter sign lamp illuminates on appears on the LCD of the remote controller and an LED on
the signal receiver unit. the unit illuminates.
to target area is possible to further increase the comfort level.
Switchable fan speed Use the temperature-sensor in
the indoor unit when controlling
High setting provides maximum reach while low setting minimises drafts. air conditioning from another
room. Control features
Auto airflow rate Note: Wireless remote controllers have no
temperature-sensor.
Auto-restart External command control
Airflow rate is automatically controlled in accordance with the
difference between room temperature and set temperature. If there is a power outage while the equipment is operating, Operation and surveillance is carried out using the contact signal from
operations will restart in the same mode as before the power the operation control box in the building surveillance (security) room.
Night quiet operation cut when electricity is restored. *An option is required.
High fan speed mode The Automatic night quiet mode will initiate 8 hours after the
You can increase fan speed approximately 10% higher than the peak temperature is reached in the daytime, and normal Central remote control
"high" setting. operation will resume 10 hours after that. Control by 2 remote controllers
Optional central remote controller enables centralised control of
Using 2 remote controllers you can operate the equipment up to 1024 indoor units (64 groups) from up to 1 kilometer away.
locally or from a remote location.
Remote Controller Note: It is not possible to use two wireless remote controllers.
Interlock control
Enables interlocking control with external equipment such as
Setpoint auto reset Off timer (programmed) Group control by 1 remote controller Heat Reclaim Ventilator.
Even if the set temperature is changed, it returns to the preset Sets and saves setting for an increment of time that You can turn up to 16 indoor units on/off with a single remote
temperature after a preset period of time. automatically turns off air conditioner after a preset period of controller. (When using connected indoor units, the settings DIII-NET communication standard
time for each time operation starts. must all be the same and on/off will be simultaneous.) Standardly equipped interface enables connection to
Setpoint range set centralised control system without need of an adaptor.
Saves energy by limiting the minimum and maximum set On/Off timer
Options
temperatures. Avoids excessive heating and cooling.
Operation starts when the preset time of the ON timer elapses
and stops when the preset time of the OFF timer elapses.
Weekly schedule timer
High-efficiency filter unit Fresh-air intake kit
Up to five operation ON/OFF settings can be programmed per
day for each day of the week. Not only can the time be set for Two types are available: 65% and 90% colorimetry. You can provide air-conditioning with fresh air from outside.
the operation ON setting, but also the temperature. Convenient for places where a ventilation fan cannot be
installed.
Ultra long-life filter
Note: *Connecting ducts, insect nets, fire dampers, air filters, and other parts should, as required,
Requires no maintenance for about 4 years* (10,000h) in be procured locally.
**Outside Air fan interlocked with air conditioning unit is necessary. Optional PCB(KRP1C63)is
22 23
LCD REMOTE CONTROLLER Optional accessory
Wireless remote
Energy saving controller
Restaurant opened Full tables at lunchtime After 30 minutes* Central remote controller Unified on/off controller Schedule timer
Temperature is set to 27ºC Then is lowered to 24ºC for Automatically returns to preset
crowded room temperature (27ºC) DCS302CA61 (Option) DCS301BA61 (Option) DST301BA61 (Option)
Returns to DCS601C51 (Option)
24 25
NOTE NOTE