Pump Control (Output Flow) - Adjust... 315C Excavator Hydraulic System #i01463370 Caterpillar
Adjust the pump output flow if the flow test results differ greatly from the specifications.
Show/hide table
Illustration 1g00764882
(21) Locknut
(23) Locknut
(25) Locknut
(27) Locknut
Adjust the flow of the right pump for the first stage of the constant horsepower control. The left
pump must be at no-load condition.
Turn adjustment screw (22) in order to adjust the output flow of the pump. Turning adjustment
screw (22) clockwise will increase the output flow of the pump. Turning adjustment screw (22)
counterclockwise will decrease the output flow of the pump. A 1/4 turn of adjustment screw (22)
will change the output flow of the pump at the following pressure.
Output flow of the pump will change approximately 12 L/min (3.2 US gpm) if the output flow is
adjusted in the pressure range of 11800 kPa (1700 psi) to 19600 kPa (2850 psi). The pump is
operating in the first stage of the constant horsepower control.
Adjust the flow of the right pump for the second stage of the constant horsepower control. The left
pump must be at no-load condition.
Turn adjustment screw (20) in order to adjust the output flow of the pump. Turning adjustment
screw (20) clockwise will increase the output flow of the pump. Turning adjustment screw (20)
counterclockwise will decrease the output flow of the pump. A 1/4 turn of adjustment screw (20)
will change the output flow of the pump at the following pressure.
Output flow of the pump will change approximately 8 L/min (2.1 US gpm) if the output flow is
adjusted in the pressure range of 27500 kPa (4000 psi) to 34300 kPa (4950 psi). The pump is
operating in the second stage of the constant horsepower control.
Adjust the left pump in the same manner as the right pump. Use locknut (27) and adjustment
screw (26) in order to adjust the first stage of the constant horsepower control. Use locknut (25)
and adjustment screw (24) in order to adjust the second stage of the constant horsepower control.
Show/hide table
Illustration 2g00764884
(29) Locknut
(30) Locknut
In order to adjust maximum output flow, turn adjustment screw (31). Turning adjustment screw
(31) clockwise will decrease the maximum output flow of the pump. Turning adjustment screw (31)
counterclockwise will increase the maximum output flow of the pump. A 1/4 turn of adjustment
screw (31) will change the maximum output flow approximately 3.3 L/min (0.87 US gpm).
Adjust the maximum output flow of the left pump in the same manner as the right pump. Use
locknut (29) and adjustment screw (28) in order to adjust the maximum output flow of the left