Anda di halaman 1dari 2
Page | of 1 NABL Accredited Lab TEST REPORT Test order / Report No. BVIPL / MT: 25941¢/1921/3/2019.. 1 Date : 06-04-2018 Date of Receipt : 19-03-2019 ASHTECH (INDIA) PRIVATE LIMITED. ‘Ashford Centre sth floor, Opp. Peninsula Corporate Park, Lower Pare! (west), Mumbal - 400013, FINAL PHYSICAL TEST REPORT ON FLY ASH Source of sample + Sample supplied by the customer. No of Samples Tested x{0ne}, Identification # + Fly Ash -Superpozz (Source - Dahanu) uIN = 19010353 Customer's Reference = Letter dt.19.03.2019 Condition of Sample Satisfactory Lab Reference Number = 2019/MAR/236857 Period of Test +: 19-03-2019 to 16-04-2019 Test Method + 1S:3812 (Part 1 & 2) : 2003 (Reaffirmed 2007) and 1S:1727 — 1967 (Reaffirmed 2008) Requirements as per sie Test Conducted Results 15:3842 2083 Part Part2 z Speatie Gravity 216 Nat specified Compressive Strength at 28 days, N/m? 4s furnished by the customer * Test Not Accredited by NABL Note: 1, The Resuits relate only tothe samples tested 2. Repor shallot be reproduce, except In ful, without the written approval ofthe lab, 2. Any correction invalidates this report. for BUREAU VERITAS INDIA PRIVATE LIMITED anagerLab ices Laboratory Sa ocd. Digh Nai Mumbai -400 708 INDIA ‘Tels +91 22 50954970 + sales.mum@in.bureauveritas.com/adminlab.mmum@in.bureauveritas.com * www bureauveritas.co.in CINAHBYPOS3 F138 HBVipl/print_flyash_phy.php?report_type=multiple&job_id=3577.... 20-Apr-19 BUREAU VERITAS (INDIA) PRIVATE LI Page | of 1 Ea) NABL Accredited Lab ‘TEST REPORT. Test order / Report No. BVIPL/ MT: 25941C/1921/3/2019 .1 Date : 06-04-2019 Date of Receipt : 19-03-2019 ULR-Te549119000003495F ASHTECH (INDIA) PRIVATE LIMITED. Ashford Cenire th floor, Opp. Peinsula Corporate Park, Lower Patel west, Mural -400033 ‘CHEMICAL TEST REPORT ON FLY ASH (PULVERIZED FUEL ASH) Source of sample Sample supplied by the customer. ‘No of Samples Tested o1{0nel. vin 19010353 Identification # ‘Superpozs - Flyash (Source Name - Dahanu) Customer's Reference etter dt.19.03,2019 Condition of Sample Satisfactory LabReference Number + 2019/MAR/296857 Period of Test 20-03-2019 to 22-03-2019 Test Method (S:1727 - 1967 (Reaffirmed 2013) Requirements as per 13812 : 2013 SiNo Test Conducted Results pute pone ‘Sliceous | Coleareous | Sifceous | Caleareous Pulverized | Pulverized | Pulverized | pulverized Fuel Ash | FuelAsh | fuel Ash | Fuel Ash 1. bossonienition, percent by mass, Maximum) [0.24 50% 5.0% 7.0% 7.0% 4 Asturished by the customer Note: 1.The Results relate only othe samples tested 2. Report shal not be reproduced, except in fl without the writen approval ofthe ib, 3 Any correction invalidates Wis repo for BUREAU VERITAS (INDIA) PRIVATE LIMITED Construction Services Laboratory Dinesh Gaikwad in he Shri Authorised Signatory Bureau Veritas (India) Pvt. Ltd. - Construction Services Laboratory Plot No. B3/B4, TTC Inds. Area, Off Thane Belapur Road, M.L.D.C., Digha, Navi Mumbai - 400 708, INDIA ‘Tels +91 22 50954870 + sales.mum(in.bureauveritss.com/adminlab.mum@in.bureauvertas.com * www:burenuveritas.ca.in CN RDE NSSF LSSSITBipyiprint_fyash_chemical, php?report_type=multiple&job_id... 06-Apr-19

Anda mungkin juga menyukai