Anda di halaman 1dari 60

NABLUS REHABILITATION CENTER - PHASE I ITB-2013-267

Page 1
NABLUS REHABILITATION CENTER - PHASE I ITB-2013-267

SECTION NO. 1
EXCAVATION, BACK FILLING AND SITE WORKS.

NUMBER OF BILLS "1"

Excavation.
General.
1. Excavation for foundation, trenches. Etc. shall be the actual dimensions shown on Drawings including
blinding area, and to be measured from Natural Ground Level or Reduced Level (which is lower), i.e.
1. From Reduced Level when R. L. is lower than N. G. L.
2. From N. G. L. when N. G. L. is lower than the Reduced Level.
2. Allowance for working space is not applicable, unless it is clearly specified in the Special Conditions.
3. Excavation for foundation of retaining walls is to be measured from Lower Reduced level, or from lower Natural
Ground level (as stated in Item 1 above.)
4. Price to include removal of site obstacles, rocks, trees and all debris from site, including any necessary rerouting of
infrastructure works, such as piping, conduits, etc .Unit price shall also include maintaining all trees that are not
obstructing the buildings, boundary walls, courts and roads.
5. Only suitable Back fill material of "Sole Wadie" shall be used and applied in compacted layers of 20cm each.
Each layer of back filling shall be tested separately, on the contractor's expense, prior to applying the next layer.
All excavations materials shall be removed from sight on a daily and continuous basis.
6. Co-ordination with all local authorities to facilitate the works, removal of obstacles or for diversion of roads,
services, etc. is the contractor's responsibility and are deemed to be included in his rates.
7. Excavated soil shall be classified and retained, to back fill with suitable fill material and to place
agricultural soil as where needed as shown in the drawings and as instructed by the Engineer. The extra and
unsuitable soil shall be removed, on the contractor’s expense with no extra cost.
8. Prior to commencement of site leveling or any excavation, the Contractor shall obtain Engineer’s written
approval on the contour grid of 5m x5m map, checked jointly by the contractor and the Engineer, the excavation
profiles and sections showing all levels and dimensions, and the calculations of excavation quantities.
9. Excavation shall be in Cubic Volume, the net measurements of the excavated elements as shown in the
Drawings, no allowance shall be made for increase in bulk after excavation.
10. Hard Core beds shall be of not less than 15 cm. thick. And measured in Meter Square, (the net measurement of the
finished surface). No extra rate shall be paid for Leveling, ramming and filling of voids under the hard core.
11.Rate of Excavation shall include: -
12.Excavation to any depth, in any shape, in any type of soil, below water table level and keeping excavation free
of water.
13.Leveling, ramming, trimming and grading excavation bottoms.
14.Planking and strutting.
15.Cost of lab. Tests of works and materials.
16.Measurements shall be taken net of foundations dimensions.
17.Extra excavations to make room for work space and form work shall be at contractor's expense, and not to be

SEC-1 EXC Page 2


NABLUS REHABILITATION CENTER - PHASE I ITB-2013-267

ITEM DESCRIPTION UNIT QUANTITY UNIT PRICE AMOUNT


NO. US$ US$
Bill No. 1 - Excavation, Back filling and Site Works
1.01 Excavation and backfilling for foundations; in any kind of
soil to the dimensions and levels shown in the drawings.
Price to include back filling with excavated soil if
suitable or imported approved materials up to
bottom of basecourse underneath slab on grade,
removal of extra and unsuitable soil. Back filling
shall be on layers of 200 mm thick with watering and
compacting to min 95% to comply with modified
AASHTO F.D.T. (T-80)

M.C 645 0.00

1.02 Supply and Well Compact Base Course, average 20 cm.


Thick, for under ground slab and tie beam blinding.
Price includes leveling, watering, compacting to 99%,
leveling and compacting of ground (sub-base) under
base Course to min 95% according to Field Density Test.

a. 20 Thick under slab on grade (Ground slab) M.S 1014 0.00

1.03 (Provisional Item) Import and fill with selected


Imported Approved Fill; to the required levels where
directed by the Engineer, only and for the quantities that
are extra and above the quantities included in item 1.01,
1.02 and 13.01.

Filling shall be on layers not to exceed 200 mm. thick.


Price to include leveling, watering and compacting to 95
% field density. Complying with Modified AASHTO
Density Test T-80. All imported fill shall be preapproved
by engineer on a truck by truck basis and prior to
entering the site. M.C 100 0.00

TOTAL CARRIED TO SUMMARY. 0.00

SEC-1 EXC Page 3


NABLUS REHABILITATION CENTER - PHASE I ITB-2013-267

SECTION NO. 2
SKELETON WORKS
NUMBER OF BILLS "3 "

SEC-2 CON Page 4


NABLUS REHABILITATION CENTER - PHASE I ITB-2013-267

ITEM DESCRIPTION UNIT QUANTITY UNIT PRICE


NO. US$
Bill No. 2 - Concrete Works
Preamble.
Rates of Concrete Works shall include:-

1. All form works and shuttering in any form, shape and


size. Making chamfered and curved edges, allowing for and
making grooves and sleeves and the like; removal of forms
and cleaning of all exposed tie wires and rods; making good
the harmed surfaces and edges and all surface finishing.

2. Supplying, Casting, vibrating and curing as per


specifications.
3. Approved additives and admixtures.

4.Incurred costs on Concrete Mix Designs, Sample taking,


testing and providing test results certificates, storing and
saving of samples, and preparation of bar bending schedules
and workshops.

5. Supplying reinforcement of any grade, size and length as


detailed in the drawings, storing on site including cutting,
bending and fixing in position and providing all tying wires,
spacers, shop drawings, testing and bar bending schedules

6. Painting of exposed surfaces of underground reinforced


concrete elements with two coats of water proofing
compound suh as (Sika ready flex, Fosroc Nitobond 30 or
equivalent), the strokes of each layer to be opposite to each
other.

7. Steel bars used for alignment and fixing of reinforcement


works, and extra steel added to assure proper detailing and
safety.

Measurement of Concrete elements shall be the net


dimensions as detailed in the drawings. All recesses
openings and voids shall be deducted.

Measurement shall be only for the seen surfaces of


elements. Overlapping and measuring items twice under
separate headings shall not be allowed.

Slabs are measured from the edge of external walls. (All


beams, drop beams, projection including fair face sun
breakers and any part casted together with the slab will be
included in the price of the slab). Columns are to be
measured from the top level of the slab to the bottom level
of the beam or dropped beam.

8. All wooden form work for any structural element and


slabs shall be made with all new wood parts.

SEC-2 CON Page 5


NABLUS REHABILITATION CENTER - PHASE I ITB-2013-267

ITEM DESCRIPTION UNIT QUANTITY UNIT PRICE


NO. US$
ITEM DESCRIPTION UNIT QUANTITY UNIT RATE
NO. US$
2.01 Supply and Cast Plain Concrete;
a) Blinding Concrete grade B150 under foundations,
footings & tie beams. Thickness should be according to M.S. 760
drawings.

Supply and Cast Reinforced Concrete grade B250. With a


minimum cement content of 300 Kg. per cubic meter. Price
to include for painting with two coats of hot bitumen
2.02 (75/25), the strokes of each layer to be opposite to each
other (for the buried parts).

a). Foundations and Wall Footings. M.C 290

Supply and Cast Reinforced Concrete grade B300. With a


minimum cement content of 350 Kg. per cubic meter. Price
to include for painting with two coats of hot bitumen
(75/25), the strokes of each layer to be opposite to each
2.03 other (for the buried parts).

a). Tie Beams. M.C 56


b) Reinforced Walls below Ground Slab Level M.C 14

Supply and Cast Reinforced Concretegrade B250. With a


minimum cement content of 300 Kg. per cubic meter For
Slab on Hard Core. Ten (10) cm. thick Slab Including surface
2.04 leveling, finishing, polyethylene sheets 500 micron,
construction joints and steel reinforcement overlapped to
tie beams, and all related works. Price includee applying M.S 1171
epoxy paint.

Supply and Cast Reinforced Concrete grade B300 with a


minimum cement content of 350 Kg. per cubic meter for:
2.05 a). Stairs, landings, flights and steps and where required. M.C 12
b). Reinforced Walls above ground slab. M.C 280

Supply and Cast Reinforced Concrete grade B300 with a


minimum cement content of 350 Kg. per cubic meter for the
2.06 following, Price to include for painting with two coats of hot
bitumen (75/25), the strokes of each layer to be opposite to
each other (for the buried parts).

a). Column portions. (Necks). M.C 12


b). Columns. M.C 45

Supply and Cast Reinforced Concrete grade B300 with a


minimum cement content of 350 Kg. per cubic meter. Price
2.07 to include for drop beams, projected beams, other beams
and projections. Price to include reinforcement steel.

a. For 20cm solid slab M.S. 67


b. For 25cm solid slab M.S. 7

Supply and Cast Reinforced Concrete Grade 'B 300' with a


minimum cement content of 350 Kg. per cubic meter for
suspended slabs. Price to include for projected beams,
other beams and projections including fair face sun
breakers, supply, lay and arrange hollow concrete blocks
2.08 'Grade 35' for ribbed slabs, using closed end blocks as
required by the engineer at all ends, edges, openings,
services location etc. measurement for slab to be from
outside edge of slab to the opposite outside edge. Price to
include reinforcement steel.

a. 30 cm thick M.S. 1381


b. 34 cm thick M.S. 125

SEC-2 CON Page 6


NABLUS REHABILITATION CENTER - PHASE I ITB-2013-267

ITEM DESCRIPTION UNIT QUANTITY UNIT PRICE


NO. US$
TOTAL CARRIED TO SUMMARY

SEC-2 CON Page 7


NABLUS REHABILITATION CENTER - PHASE I ITB-2013-267

ITEM DESCRIPTION UNIT QUANTITY UNIT PRICE


NO. US$
Bill No. 3 - STEEL STRUCTURE WORKS
(Provisional Item) Supply, assemble and install a structural
steel roof, complete with steel beams (IPE240), and main
truss units, as well as side sway truss and lateral support, all
from hollow tubular sections as described in the
accompanying plans and details. Structure to be covered
with two layers with 5cm spacing of galvanized sheet metal
with the bottom layer being 0.63mm thick corrugated
sheets, and top layer 0.63mm thick corrugated pre-painted
with reflective type paint. Overlap between sheets shall not
be less than 15cm; an approved water tight insulation to be
applied to the entire overlap area shall be included in the
price here in. Price shall include rock wool or polyurethane
foam insulation between the two layers. Purlins, C12x5x1.5
shall be welded to the trusses (using gusset plates) at 45 cm
spacing to support the sheet metal cover. Support plates
3.01 shall be pre-assembled and welded and made ready prior to
structure assembly. All welding shall conform to AWS CODE
d1.1-99 and to appropriate ASTM standards. All materials
supplied shall be subject to laboratory testing, including
welded joints, to verify physical properties and strength.
Bolts shall be of grade 8.8 for anchor bolts embedded in
concrete and of grade 10.9 for all other bolts used.

laboratory testing, including welded joints, to verify physical


properties and strength. Bolts shall be of grade 8.8 for anchor bolts
embedded in concrete and of grade 10.9 for all other bolts used.

Price shall also include vertical column elements and joints


with concrete columns as per details.
All metal parts shall be painted rust proofed and powder
coated with color as directed by the engineer.

The contractor shall provide complete shop drawings,


including accurate dimensions of all parts and elements to
be used. No additional allowance shall be made for any
additional welds, support plates or any other metal parts as
might be needed for strengthening.

Price incldues sand blasting and three coats epoxy paint M.S. 210

TOTAL CARRIED TO SUMMARY

SEC-2 CON Page 8


NABLUS REHABILITATION CENTER - PHASE I ITB-2013-267

ITEM DESCRIPTION UNIT QUANTITY UNIT PRICE


NO. US$
Bill No. 4 - STONE WORKS
PREAMBLE.
All Stone works shall be of local white stone of First Choice.
Stone material, size, and texturing shall be in accordance
with detailed drawings and Engineer’s instructions and
approval.
Stones shall be of not less than (5 cm. thick, 25 cm. high
and of length ranging from 1.5 to 3 times the height.)
Stones shall be homogeneous in color and texturing and
free of any defects.
Cutting, shaping and building of stone shall be in straight
angles, no twisting, distortion or uneven sizes shall be
allowed.
All cuttings shall be made using Manjal.
Measurement of all types shall be in Meter Square, for the
net dimensions of the vertical plan of the elevations
excluding openings of any area.

No measurement will be made for any recesses,


projections or sides of stone pieces.
Measurement of door and window jambs and reveals,
corner peaces, and the like is not applicable.
No allowances shall be made for stone pieces in any shape.
No allowances or extra rates shall be considered for stone
courses in lintels, overhanging slabs and roof slab courses.
Taking all the above-mentioned into account,
measurement for stone cladding works will follow the
shape of the clad element.
Rates of stone works shall include:-
· Supplying , storing, protection and removal of rejected
and surplus materials.
· Shaping, cutting and fitting.
· Mortar and backing concrete (plain concrete and/or
cement blocks and plain concrete).
· Galvanized steel ties, dowels, hangers, steel mesh and all
tying tools.
· Erecting and dismantling of scaffoldings.
· Pointing and pointing materials of any type, and cleaning
of walls.
· Lintels and other reinforced concrete elements embedded
in the stonewalls including reinforcement.
. 3Cm high density Polystyrene boards for insulation
between concrete and concrete blocks.

SEC-2 CON Page 9


NABLUS REHABILITATION CENTER - PHASE I ITB-2013-267

ITEM DESCRIPTION UNIT QUANTITY UNIT PRICE


NO. US$
Supply and Build Stone Walls;
Supply and build stone walls to the full length and height as
shown in the drawings , first class and first quality polished
finish

a) SW1 white stone walls34 cm thick masonry wall (Jamaeen


stone or equivalent) with plain concrete (B-200), 2cm M.S. 343
4.01 thermal insulation polyester boards and cement (concrete)
block backing Grade 35 (10*20*40cm).

b) SW2, Ditto, but yellow stone walls 34 cm thick masonry M.S. 180
wall from (Birzeit stones or equivalent).
c) SW1 parapet walls, thickness as shown on drawings. M.S. 140
d) SW2 parapet walls, thickness as shown on drawings. M.S. 70

Supply and build Stone cladding facades over reinforced


concrete walls, walls between tie beams and slab on hard
core, slab beams. Columns ( As shown on AD00) according
to Palestine Standards Institution (NO. 113). Price to
include concrete filling of plain concrete Grade B-250, steel
mesh and all ancillaries, first class and first quality polished.

Price not to include for the reinforced concrete elements to


4.02 be caddied, which is to be measured under another item.
a) SW1, Masonry stone wall cladding (Jamaeen stone or M.S 426
equivalent).
b) SW2, Masonry stone wall cladding (Birzeit stones or
equivalent) M.S 425

c) SW2, Masonry stone wall for internal columns cladding M.S 65


(Birzeit stones or equivalent)
Supply, Build stone coping for parapets, head of columns,
and balcony wall parapets as shown on details.
4.03
a. Coping for SW1 (Jamaeen stone or equivalent). M.S. 65

b. Coping for for SW2 (Birzeit stones or equivalent). M.S. 27

TOTAL CARRIED TO SUMMARY

SEC-2 CON Page 10


NABLUS REHABILITATION CENTER - PHASE I ITB-2013-267

ITEM DESCRIPTION UNIT QUANTITY UNIT PRICE


NO. US$
Bill No. 5 - HOLLOW CONCRETE BLOCKS WORKS
PREAMBLE.

All works of this bill shall be of Concrete blocks Grade 35 of


high quality standards and as per specifications.

Block works shall be measured in meter square. The net


measurement of the complete elevations, excluding all
openings and voids more than 0.1 M. S. in area.

No allowance for thickness used other than those shown in


the drawings.

Rates of Block works include:-

· Vertical and horizontal joints.


· Cement and mortar,
· Galvanized angles butter fly ties (at joints and
between walls in cavity walls.

· Concrete filling at all ends including reinforcing steel


to cavities at quoins and door and window openings,
reveals, sills for windows and the like.
· R.C. Door Walls and jambs for classroom doors AND
others as per detailed drawings
· Lintels and bond beams to the full length of the wall,
min 20 cm. High and in the same wall thickness of
reinforced concrete grade B-200 with due reinforcement
steel, on top of doors and windows or as specified per
drawings.
· Window jambs of min. 20 cm width and in same wall
thickness to full height of window.
· And all needed to complete job as per drawings and
specifications.
Supply and Build Concrete Block Walls, 'Grade 35’of any
size blocks.

5.01 a) Hollow Blocks (10 Ten) cm. Thick. M.S 148

b) Hollow Blocks (20 twenty) cm. Thick for internal


partitions and parapet. M.S 450

TOTAL CARRIED TO SUMMARY

SEC-2 CON Page 11


NABLUS REHABILITATION CENTER - PHASE I ITB-2013-267

SEC-2 CON Page 12


NABLUS REHABILITATION CENTER - PHASE I ITB-2013-267

AMOUNT
US$

SEC-2 CON Page 13


NABLUS REHABILITATION CENTER - PHASE I ITB-2013-267

AMOUNT
US$
AMOUNT
US$

0.00

0.00

0.00
0.00

0.00

0.00
0.00

0.00
0.00

0.00
0.00

0.00
0.00

SEC-2 CON Page 14


NABLUS REHABILITATION CENTER - PHASE I ITB-2013-267

AMOUNT
US$
0.00

SEC-2 CON Page 15


NABLUS REHABILITATION CENTER - PHASE I ITB-2013-267

AMOUNT
US$

0.00

0.00

SEC-2 CON Page 16


NABLUS REHABILITATION CENTER - PHASE I ITB-2013-267

AMOUNT
US$

SEC-2 CON Page 17


NABLUS REHABILITATION CENTER - PHASE I ITB-2013-267

AMOUNT
US$

0.00

0.00

0.00
0.00
0.00

0.00

0.00

0.00

0.00

0.00

0.00

SEC-2 CON Page 18


NABLUS REHABILITATION CENTER - PHASE I ITB-2013-267

AMOUNT
US$

0.00

0.00

0.00

SEC-2 CON Page 19


NABLUS REHABILITATION CENTER - PHASE I ITB-2013-267

SECTION No. 3

INTERNAL FINISHES

NUMBER OF BILLS " 5 "

SEC-3-finishing_2r Page 20
NABLUS REHABILITATION CENTER - PHASE I ITB-2013-267

ITEM DESCRIPTION UNIT QUANTITY UNIT PRICE


NO. US$
Bill No. 6 - PLASRERING
PREAMBLE.
PLASTERING to all areas shall be measured net, including openings,
which are less than 0.25 Meter Sq.
The price shall include for running rules , all narrow
widths, for taking out joints on block walls or backing concrete face
for key, for making good to frames around pipes and other
fittings , plastering to jambs and reveals of openings, side of columns,
window sills; all of which shall be measured as plastering .

Price shall also include Expanded metal lath, angle beads at all
appeared corners for the entire height, and plaster stops at opening
edges, expansion joints, sills, labor, curing, erecting and dismantling
of scaffoldings, additives, pigments and all incidentals required as
specified and / or detailed on the Drawings.

6.01 Two Coats of Cement and Sand Plaster over one slurry coat to walls
and ceilings and where required including metal Lath, angle beads,
plaster stops and all required as per Specifications and Drawings.

a. Internal plaster wherever indicated on drawings and according to


specifications.

a-1 Ceilings including drop beams & Walls M.S. 580

a-2 Wall plaster M.S. 6140

b. Ditto, but for External plaster for :

b-1. parapet walls and roof staircase walls , price to include


waterproofing additive such as (Sika Latex, Nitobond SPR 201, or M.S. 400
equivalent) with the last face.

b-2. Ditto but plaster for water well walls M.S. 160

TOTAL CARRIED TO SUMMARY

SEC-3-finishing_2r Page 21
NABLUS REHABILITATION CENTER - PHASE I ITB-2013-267

ITEM DESCRIPTION UNIT QUANTITY UNIT PRICE


NO. US$
Bill No. 7 - TILING WORKS
PREAMBLE.
1. All tilling works (porcelain, ceramics and marble) shall be measured
net in square meters. Deducting all opening and voids more than 0.25
M.S.
2. Marble works for steps and treads of stairs shall be measured in
linear meter. The tread, the riser, flight skirting and water stop shall
all be measured as a single unit in linear meter.

3. Marble works for window sills and other openings shall be


measured in linear meter.
4. Rate shall include preparation of surfaces under tiles, Finish to falls
and cross falls, special tile pieces for edges and the like, tile surface
fiNIShing, Plastic spacers. Pointing and cleaning and all incidentals as
per specifications.

5. Rates shall include also providing and mounting in place “Project


Title Marble Plate” of white Carrara marble polished, finished and
engraved in the design provided by UNDP (dimensions 70cm high
x100cm wide).
6. Price includes pointing with approved ready mix mortar compound
and cleaning of site.
7.01 Supply and Install Granite Porcelain Tiles 40x40x0.8 cm (Turkish, M.S. 640
Spanish, or equivalent), first choice and free from all defects Grade “A”.
(Approved by Palestine Standards Institution).

7.02 Supply and Install Non-Slip Porcelain Floor Tiles (Turkish, Spanish, or
equivalent)
First choice and free from all defect grade “A”. (Approved by Palestine
Standards Institution). Price to include sand with cement filling (Grade
B-100).

Engineer shall approve size and color.


a) for cafeteria kitchen floors 20x20x0.8 cm (Provesional item) M.S. 60
b) for bathroom and kitchen floors 30x30x0.8 cm M.S. 40
c) for pool tiles 20x10x1cm, price includes two coats plastering with M.S. 28
water proofing additives, special pool specific adhesive compound,
special pool specific epoxy mortar. (Provisional item)

7.03 Supply and Install Ceramic wall Tiles (Turkish, Spanish, or equivalent)
for bathrooms and kitchens. First choice and free from all defects
Grade “A”. (Approved by Palestine Standards Institution). Price includes
two coats plaster.

a) 20x30x0.6cm for bathroom and kitchen walls M.S. 180


b) 20x30x0.6cm for pool room and laundry walls (Provisional) M.S. 164
7.04 Supply and Install Local Marble Sills, Thresholds, and wherever needed
(3 cm. thick).
Set in cement mortar bedding price to include grouting, polishing of M.S. 10
face and seen edges.
7.05 Local Marble for Steps and Treads of Stairs.
Supply and install treads of 3 cm thick andrisers of 2 cm. thick. Price
shall include supplying anf installing local marble water stop (5cm wide
x 3cm thick x length as wide as the tread of the stair minus riser
thickness) fixed at the end of treads. Also the price to include filling
under tiles with cement and sand 1: 6 ratio, bedding in cement mortar,
grouting, pointing, polishing of face and all related works.

M.R. 78
Note: The measurement for each stair will be from the adjacent wall to
the external edge of the water stop of that stair.
7.06 Ditto but skirting for flights M.S. 22
7.07 Ditto but for landings M.S. 35
7.08 Ditto but for elevator walls M.S. 23
TOTAL CARRIED TO SUMMARY

SEC-3-finishing_2r Page 22
NABLUS REHABILITATION CENTER - PHASE I ITB-2013-267

ITEM DESCRIPTION UNIT QUANTITY UNIT PRICE


NO. US$
Bill No. 8 - CARPENTRY WORKS
PREAMBLE.
Sizes of carpentry works given in the Bills of Quantities are fiNIShed
sizes and shall be as per Drawings.
Sizes of doors and other items mentioned in the Bills of Quantities
shall allow for tolerance to suit the structural openings shown in the
Drawings.

· Wooden doors and pair of doors shall be measured in number for


each structural opening, unless stated otherwise in the Bills of
Quantities.

· Wall protection wooden rubbing rails shall be measured in linear


meter.
· Cloth hangers and hanger wooden base shall be measured in
number or in linear meter as stated in the Bills of Quantities.

Rates for carpentry and joinery work shall include :


a) Shop and coordinated drawings.
b) Frames, architrave, chalk holders and other holders and 20 cm.
high “U” shape kick plates.
c) Allowance for plastering and tiling and the like.
d) Cutting and fitting around obstructions, Bedding and painting.

e) Grounds, blocking and backings.


f) Plugging concrete, block work, and stone work, and making well.

g) Ironmongery including "Tesa" or equivalent cylinders, cylindrical


locks with master key for all the doors, handles type "Tesa" or
equivalent, screws, temporary fixing, re-fixing, oiling and adjusting.
All to be silver color.

h) Providing three keys for each lock including tagging.


i) Providing and fixing wall mounted wooden keys cabinet,
(70*70*10) cm. varnish finished with all ironmongery including
cylindrical lock.

j) Providing and fixing Room Title Plat, aluminum (30*20) cm.


mounted on wooden plate (35*25) with varnish finish.

k) Steel legs, brackets, bearers and other supports including painting.


l) Glass and glazing including cutting to size and putty.
m) Fly screening including cutting to size.
n) Preparing surfaces to receive finishes.
o) Painting, varnishing, polishing, oiling, and the like, to any area or
width in any location including work in multicolor and cutting in
edges and putty.

SEC-3-finishing_2r Page 23
NABLUS REHABILITATION CENTER - PHASE I ITB-2013-267

ITEM DESCRIPTION UNIT QUANTITY UNIT PRICE


NO. US$
8.01 Supply and Fix Wooden Doors 4.5 cm Thick single or double sashes.
With (galvanized steel frame) and (4.5*3.5) cm (Swedish) wood edging
and (3.5*9.5) cm soft wood stile. Edge strip banding of width 4.5 mm.
Formica veneer 0.6 mm on both sides, color as directed by engineer.
Door paneling to be soft wood 4.5*3.5 cm. each 4 cm. Frames of
galvanized steel, width according to the wall thickness and allowance of
4 - 6 cm. thickness for plastering and tiling purposes, painted three
coats including wash primer, then embedded completely in sand -
cement mortar and completely anchored as per specification.

Price to include ironmongery, kick plates of aluminum, U shaped both


sides, and door stoppers, gaskets cylindrical Lock (Approved by
Palestine Standards Institution), and painting in three coats of oil paint
in addition to primer coat. Price to include treated wood frame and
architrave of Hardwood (Swedish) (7*1.2) cm where shown on
drawings.

All as per Detailed Drawings, specification and instructions of


supervisor engineer.
a. WD1 Structural opening size (100 * 210) cm. NO. 10
b. WD2 Structural opening size (90 * 200) cm. NO. 7
c. WD3 Structural opening size (80 * 200) cm. NO. 4
d. WD4 Structural opening size (120 * 210) cm. (Provisional item) NO. 3
e. WD5 Structural opening size (100 * 215) cm. NO. 1
f. WD6 Structural opening size (180 * 240) cm. NO. 2
g. WD8 Structural opening size (100 * 210) cm. NO. 1
h. WD9 Structural opening size ( 90 * 210) cm. NO. 1
j. WD10 Structural opening size (100 * 120) cm. NO. 3
k. WD11 Structural opening size (30 *120) cm. NO. 3
TOTAL CARRIED TO SUMMARY

SEC-3-finishing_2r Page 24
NABLUS REHABILITATION CENTER - PHASE I ITB-2013-267

ITEM DESCRIPTION UNIT QUANTITY UNIT PRICE


NO. US$
BILL No. 9 -METAL & GLASS WORKS
9 Preamble.
Metal works shall be measured in number.
Rates for metalwork shall include for :
Preparing shop drawings,
Drilling, counter sinking, screwing, bolting and riveting.
Lugs, plugs, holdfasts and the like.
Gaskets, sashes, double weather strips and external and internal
silicon filling around frames.
Ironmongery including cylinders, cylindrical locks (Union or equal),
stoppers, handles, temporarily fixing, re-fixing, oiling and adjusting.
Providing three keys for each lock and padlock including tagging and a
master key for all doors.
Hardware including cramps, dowels and the like.
Glass and glazing to be 6mm thick with color as directed by the
engineer, including cutting to size, putty and rubber.
Preparing surfaces for painting one coat of primer before fixing.

Sealing and Painting to any area or width in any location including


work in multicolor and cutting in edges.
Price includes the supply and installation of painted galvanized steel
sheets size 25x25cm fixed on 16mm ply wood to be installed next to
each door. Price also includes the supply and installation of the
directory plates size as shown in the attached form.

All other accessories and incidentals required to execute the work.

9.01 Supply, fix and operate sliding Puff Aluminum Windows.


Extrusion Section 7700 or equal three channel, with protective
electrostaticaly applied polyester powder paint anodized of 70-80
microns. In color approved by the Engineer.

Price to include, 6 mm .double tented Float colored glazing , fly screen


and all other accessories and fittings to complete works as per
drawings and specifications.

a) Window Type W-2 size (1.32*1.51) m, price includes shutter with box NO. 1
and electric motor. (Provisional item)
b) Window Type W-3 size (1.60*1.51) m, price includes shutter with NO. 15
box and electric motor.
c) Window Type W-4 size (1.20*1.51) m, price includes shutter with box NO. 3
and electric motor.
d) Window Type W-5 size (0.8*1.25) m NO. 3
9.02 Ditto, but aluminum doors
ALD1 NO. 1
9.03 Supply and Install Protection Steel Grills ,Price to include fixation,
accessories, welding, grinding & smoothening.
Price also to include oil painting three coats in addition to two primer
coats for:
b) P2 1.60x1.51 NO. 15
c) P3 1.20x1.51 NO. 3
d) P4 0.8x1.29 NO. 3
e) P5 price includes shutter box and motor NO. 1
f) P6 price includes shutter box and motor NO. 3
g) P7 NO. 1
TOTAL MOVED TO NEXT PAGE

SEC-3-finishing_2r Page 25
NABLUS REHABILITATION CENTER - PHASE I ITB-2013-267

ITEM DESCRIPTION UNIT QUANTITY UNIT PRICE


NO. US$
FORWARDED TOTAL
9.04 Supply and Fix galvanized steel handrail as per drawings.
a. Stair Handrails as shown on drawings of galvanized steel. Price to
include wood handrail, fixing complete, oil paint three coats in addition
to primer coat according to details. Steel parts include three coats
paint including wash primer.
M.R. 16
b. Supply and install Beach wood grab bars according to drawings and
details. M.R. 16
c. Balcony and terrace handrails of galvanized steel as shown in
drawings. Price to include fixing complete, three coats paint including M.R. 7.5
wash primer.
d. Ditto but pvc wall protection strips.
M.R. 91
9.05 Supply and install Tempered Glass partitions and doors. Price includes
all accessories, handles, locks, pneumatic door hinges, all fixed
elements, spiders.
a) Tempered glass partitions 10mm thick, complete with stainless steel
frames and supports, stainless steel spider joints, clear rubber seals, M.S 28
etc..
b) GD2 .NO 1
9.08 Aluminum Curtain walls. Price includes double pane tempered glass
with 6mm thick tempered outer pane and 6mm tempered inner pane,
price also includes tempered glass doors, fittings, hinges, locks, sand
blasting patterns, bolts, and all connections as manufactured by Dorma
or equivalent, fittings colors same as aluminum color. Price also
includes window openings. Price also includes aluminum sun visers.
Contractor to supply all shop drawings prior to execution of work. Price
includes all necessary steel structure, including galvanizing and painting
of all elements, all supports, brackets, etc… Price also includes
aluminum sheet cladding of all exposed concrete and steel elements as
shown on drawings.

M.S 25
9.09 Supply & Install top and bottom aluminum and galvanized kitchen
cabinets. Cabinet's top, internal partitions, sides, and shelves shall be
granite 30 mm. thick with polished surface and edges. Drawers front-
side and elevations shall be of aluminum frame and insulated
aluminum sheets. The whole cabinet shall be framed with galvanized
steel frame and painted three coats paint including wash primer.
Drawer's bottom shall be of 6 mm, thick insulated aluminum sheets.
Price to include ironmongery, handles, and all the accessories as per
drawings and Specifications .

SIZE: Height (90) cm. Width (60) cm. Detailed Drawings)


a-for kitchen bottom cabinets M.R 6
b-for kitchen top cabinets M.R. 6
TOTAL CARRIED TO SUMMARY

SEC-3-finishing_2r Page 26
NABLUS REHABILITATION CENTER - PHASE I ITB-2013-267

ITEM DESCRIPTION UNIT QUANTITY UNIT PRICE


NO. US$
BILL No. 10 - FALSE CEILING & PAINTING WORKS
Preamble
Painting and decorating to walls, ceilings and the like shall be
measured net in meter square.
Painting to other works shall be included in the related items. Color
as specified by engineer.
Paints shall be supplied to site in sealed container, as approved by the
Engineer, and site mixing shall not be permitted.
The Contractor rates shall include for supply of all materials,
workmanship, samples, primers, surface preparation, protection of
painted surfaces, application to all heights as required of works,
repair of all damaged surface at the contractor’s expenses, and all
other requirements as stated in the Specifications.

All paint types should be approved and having a supervision


certificate from the PSI.
10.01 Supply and paint high quality supercryl paint for walls as per indicated
in finishing tables, on one priming coat and two finishing coats, using
two coats of complete putty, as per satisfaction of the supervisor
engineer. M.S. 1240
10.02 Supply and paint three coats Polycide paint for ceilings of high quality
(Approved by Palestine Standards Institution). M.S. 213
10.03 Ditto, but exernal quality paint for parapets and external walls. M.S. 145
10.04 Ditto, but for Gypsum Board Ceilings. M.S. 191
10.05 Ditto, but for Gypsum Board Steps. M.S. 124

Gypsum Board Partitions, ceilings, and acoustic tiles ceilings and the
like shall be measured net in meter square.
The Contractor rates shall include for supply of all materials,
workmanship, samples, primers, surface preparation, protection of
surfaces, application to all heights as required of works, repair of all
damaged surface at the contractor’s expenses, and all other
requirements as stated in the Specifications.

10.06
Supply and install tegular edge acoustic tiles 60x60 cm, using L & Z
section frames and heavy duty USG or equivalent T sections and USG
or equivalent hangers. Tiles shall be non-combustible type as specified
in the specifications. M.S. 131
10.07 Ditto, but metal False Ceiling.

a) 30cm wide panels M.S. 24


b) 60x60 cm M.S. 11
10.08
Ditto, but would and opaque glass false ceiling. M.S. 10
10.09
Supply and install gypsum board false ceiling, price includes application
of two coats of complete Tals putty for the entire area of the gypsum
board as per satisfaction of the supervisor engineer. M.S. 191
10.10 Ditto, but gypsum board steps M.R. 124

TOTAL CARRIED TO SUMMARY

SEC-3-finishing_2r Page 27
NABLUS REHABILITATION CENTER - PHASE I ITB-2013-267

SEC-3-finishing_2r Page 28
NABLUS REHABILITATION CENTER - PHASE I ITB-2013-267

AMOUNT
US$

0.00

0.00
0.00
0.00
0.00

0.00

0.00

SEC-3-finishing_2r Page 29
NABLUS REHABILITATION CENTER - PHASE I ITB-2013-267

AMOUNT
US$

0.00

0.00
0.00
0.00

0.00
0.00

0.00

0.00

0.00
0.00
0.00
0.00

SEC-3-finishing_2r Page 30
NABLUS REHABILITATION CENTER - PHASE I ITB-2013-267

AMOUNT
US$

SEC-3-finishing_2r Page 31
NABLUS REHABILITATION CENTER - PHASE I ITB-2013-267

AMOUNT
US$

0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00

SEC-3-finishing_2r Page 32
NABLUS REHABILITATION CENTER - PHASE I ITB-2013-267

AMOUNT
US$

0.00

0.00

0.00

0.00

0.00
0.00
0.00
0.00
0.00
0.00
0.00

SEC-3-finishing_2r Page 33
NABLUS REHABILITATION CENTER - PHASE I ITB-2013-267

AMOUNT
US$
0.00

0.00

0.00

0.00

0.00

0.00

0.00
0.00

0.00
0.00
0.00

SEC-3-finishing_2r Page 34
NABLUS REHABILITATION CENTER - PHASE I ITB-2013-267

AMOUNT
US$

0.00

0.00
0.00
0.00
0.00

0.00

0.00
0.00
0.00
0.00

0.00

0.00
0.00

SEC-3-finishing_2r Page 35
NABLUS REHABILITATION CENTER - PHASE I ITB-2013-267

SECTION No. 4

INSULATION , ROOFING & EXPANSION and/or SEISMIC JOINTS

NUMBER OF BILLS " 1 "

SEC-4-Proofing_2 Page 36
NABLUS REHABILITATION CENTER - PHASE I ITB-2013-267

ITEM DESCRIPTION UNIT QUANTITY UNIT PRICE AMOUNT


NO. US$ US$
BILL No. 11 - INSULATION , ROOFING AND EXPANSION JOINTS
Preamble.
All finishes shall be measured superficially net unless other wise
stated clearly.
All finishes, include triangular shaped fillets except cement and sand
lining to gutters, shall be measured on the slab surface only, parapets
and column stubs to be included in the price and not to be measured.

Cement and sand lining to gutters shall be measured in linear meter,


unless other wise stated clearly.
Rates for cement and sand work shall include for :
Hacking concrete, applying cement slurry or raking out joints of block
work to form key. Application to any surface.
Finish to surface, to falls, cross-falls and currents.
Forming bays including joints. Finish to edges and arises.
Making good around steel sections, pipes, tubes, bars, brackets,
outlets, and the like.
Measurement for concrete screed and waterproofing membrane shall
be for horizontal projection of roof area as calculated on roof plan
between plastered surfaces of parapets and walls only. Corner
chamfers and vertical waterproofing shall not be measured. Expansion
joint waterproofing shall not be measured, and is included in
expansion joint unit prices.

Rates for waterproofing and roof sheeting shall include for


Preparation of surface, cutting in edges. Overlaps priming and
treatment at the corners and floor drains.
Dressing over parapets and stub columns including forming groove to
receive edge of plasticised bitumen membrane and sealing with
elastic sealer.

Side and end laps, Fittings including bolts, hook bolts, screws and
washers,
Sheets of any width or length.
11.01 Supply and cast in place lightweight plain concrete for screed to roof
with 1% slope, cast to falls not less than 3cm thickness in the drain
point, rate to include lining and hunching 10x10 cm with (45˚) to the
edge of roof screed and parapet, rate also include smooth surface
finish to receive bitumen and all requirements as per specifications, .M.S 635 0.00
. drawings and Engineer's instructions

11.02 Supply and apply waterproofing membrane of bitumen rolls. (4.5 mm.
thick. Density 180g per m.s. of reinforced polyester sheets) type SPS
covered with layer of crushed white stone with overlaps of not less
than 10 cm. price to include primer coat, and all sheets flashing. For
roof of main building, and roof of staircase .measurement shall be for
horizontal projection of roof, unit rate includes vertical elements on .M.S 635 0.00
parapets and walls.

11.03 Ditto, but for basement walls including protective dimple sheets. M.S. 315 0.00

TOTAL CARRIED TO NEXT PAGE. 0.00

SEC-4-Proofing_2 Page 37
NABLUS REHABILITATION CENTER - PHASE I ITB-2013-267

ITEM DESCRIPTION UNIT QUANTITY UNIT PRICE AMOUNT


NO. US$ US$
FORWARDED TOTAL 0.00
11.04 Supply and apply water proofing membrane such as (Seka top 107 ,
Nitocoat CM21, or equivalent) for the following:
a) Sanitary units, applied in two layers to the full area of floor and up
to 15 cm high of walls M.S 40 0.00
b) Parapet and external walls. 250
M.S. 0.00
c) Water well walls and floor M.S. 160 0.00
11.05 Supply and Fix Aluminum Cover to Expansion and/or seismic Joints for
floors, walls and ceilings. Price to includes Polyurethane filler board,
mastic fill, backing rod, fixing with galvanized clips every 30 cm. and all
.accessories in accordance with details and relative specifications

a. Internal horizontal expansion joint through floor and tiles M.R. 13 0.00
b. External Vertical expansion joint M.R. 72 0.00

TOTAL CARRIED TO SUMMARY. 0.00

SEC-4-Proofing_2 Page 38
NABLUS REHABILITATION CENTER - PHASE I ITB-2013-267

Section 06 - ELECTRICAL WORK


Preamble

The Electrical BOQ shall be read in conjunction with parts of the electrical technical specifications
general and particular and the Electrical Drawings except where otherwise indicated.

The unit price for all items in Electrical BOQ shall include supplying, installing, testing, and
commissioning, unless otherwise specifically mentioned.

All Civil and Finishing Works related to the concerned item shall be included in the unit price, unless
otherwise mentioned.

The Contractor shall submit detailed shop drawings for all electrical drawings to take approval from
the Engineer.

The contractor shall coordinate with the local power authorities and get their approval for electrical
works.

The contractor shall be responsible for executing and commissioning the electrical works complying
with the local power authorities regulations.

The fire alarm system shall comply with the requirements of NFPA 72.

Perforated cable tray shall be used in power system and mesh cable tray shall be used for
telecommunication systems

The price of generator and UPS shall include field test.

Electrical works shall conform to all applicable codes and standards including but not limited to:

National electric code NFPA70, NFPA72, NFPA 76, NFPA101, NFPA110


ANSI/TIA/EIA-607, ANSI/TIA/EIA-569

Elect Phase 1 Page 39


NABLUS REHABILITATION CENTER - PHASE I ITB-2013-267

Description Unit Price Amount


Item Unit Qty
US$ US$
BILL No. 12 - Building Electrical Works
Power System
12.1 Distribution boards

Supply, install, test and commission a distribution board inclusive of all


circuit breakers type Eaton or equal approved for outgoing and
incoming cables, bus bars and their coupling units, casing spaces for
cables, cable clamps/terminals, cable shoes, protection equipment, as
required to form a complete unit. All shall be in accordance with the
drawings, specification (IEC61439), and the codes of practice and the
highest prevailing standards of engineering. The rate includes AMDAR
controller for central shutters in specified distribution boards as
shown in the drawings.
The Contractor shall submit detailed shop drawings for the boards to
take approval from the Engineer before manufacturing.

12.1.1 KWHM according NDECO regulations No 1 0.00


12.1.2 Sub-MDB No 1 0.00
12.1.3 DBGa No 1 0.00
12.1.5 MDBU No 1 0.00
12.1.6 MCC No 1 0.00
12.1.7 Supply, install, test and commission a complete 20 KVAR power factor
panel upgradable to 115 KVAR inclusive of automatic power factor
controller (Lavoto type), cabinet capacitor, cables, bus bars and their
coupling units, casing spaces for cables, cable clamps/terminals, cable
shoes, protection equipment, as required to form a complete unit. All
No 1 0.00
shall be in accordance with the drawings, specifications, codes of
practice and the highest prevailing standards of engineering.

Cables:
12.2
Supply, install, test and commission 600/1000V XLPE copper cables
including glands, cable ties, labeling, and all associated accessories
according to the drawings, specifications and relevant codes of
practice and highest prevailing engineering standards, for the
following:
12.2.1 5x10 mm2 MR 100 0.00
12.2.2 3x6 mm2 for MDBU MR 35 0.00
12.3 Electrical outlets
12.3.1 Supply, install, test, number and commission a complete single phase
single socket outlet for power, including cables(3x2.5 mm2 N2XY),
conduits, boxes, socket outlets (type Legrand or equally approved),
and all connections between the appropriate distribution board and the No 41 0.00
terminal point, as specified and as detailed on drawings.

12.3.2 Supply, install, test and commission as per item (12.3.1) but single No 4 0.00
phase double socket outlets.
12.3.3 Supply, install, test and commission as per item (12.3.1) but single
No 5 0.00
phase water proof socket outlets.
12.3.4 Supply, install, test and commission as per item (12.3.1) but single
phase double socket UPS outlets. No 15 0.00
12.3.5 Supply, install, test and commission as per item (12.3.1), but single
No 8 0.00
phase single socket UPS outlet.
12.3.6 Supply, install, test and commission as per item (12.3.1), but 16A
No 2 0.00
single phase outlet for electrical slide doors.

TOTAL CARRIED TO NEXT PAGE 0.00

Elect Phase 1 Page 40


NABLUS REHABILITATION CENTER - PHASE I ITB-2013-267

Description Unit Price Amount


Item Unit Qty
US$ US$
FORWARDED TOTAL 0.00
12.3.7 Supply, install, test and commission as per item (12.3.1), but single
phase outlet with double pole switch for A/C. No 12 0.00

12.3.8 As above but for exhaust fan and heat reclaim unit. No 2 0.00
12.3.9 Supply, install, test, and commission a complete 3x32A surface
mounted rotary switch IP65 type Eaton or equally approved including
cables(5x6 mm2 N2XY), conduits, boxes and all connections between
the appropriate distribution board and the terminal point, as specified No 3 0.00
and as detailed on drawings.

12.3.10 Ditto as above item but 1x20A with 3x4mm2 N2XY cable for pumps.
No 4 0.00

12.3.11 Supply, install, test and commission a stainless steel hand dryer,
automatic type, operated by photo cell, surface type, AC supply, 1500
W, 220V, 50Hz, Including cables, conduits, boxes and all other
accessories to connect from the appropriate distribution board to the No 9 0.00
hand dryer as specified and detailed on drawings.

12.3.12 Supply, install, test and commission a central shutter switch Including
cables, conduits, boxes and all other accessories to connect from
shutter controller in appropriate distribution board to each window as No 19 0.00
specified and detailed on drawings.

12.3.13 As above item but master shutter switch No 2 0.00


12.4 Cable Trays
12.4.1 Supply, install and connect 30 cm perforated cable tray type OBO, for
high current systems complete with all mounting accessories, tees,
reducers, elbows, and all accessory need to complete the work. All
shall be in accordance with the drawings, specifications, the codes of MR 40 0.00
practice and the highest prevailing standards of engineering.

12.4.2 Supply, install and connect 30 cm heavy duty cable tray, mesh type for
low current systems complete with all mounting accessories, tees,
reducers, elbows, and all accessories needed to complete the work.
All shall be in accordance with the drawings, specifications, codes of MR 35 0.00
practice and the highest prevailing standards of engineering.

12.5 Earthing system


12.5.1 Supply, install, test and commission 30x3mm galvanized steel strip
welded to building foundation reinforcement and connected to the
equipotential busbar, including all required materials, boxes, testing
terminals, equipotential busbar and all required accessories all in LS 1 0.00
accordance with the specification, drawings, and codes of practice.

12.5.2 Supply, install, test and commission a complete earthing system for
the building including all conductors, copper bars, tape-clamps,
conduits, manholes, and its heavy duty steel 25 Ton cover, fixing, etc., LS 1 0.00
all in accordance with the specification, drawings, and codes of
practice.

12.5.3 Supply, install, test and commission a complete ring grounding system
for mechanical and electrical plants, cable tray and all big metallic
masses, etc., including all conductors, copper bars, clamps, conduits LS 1 0.00
fixing etc., all in accordance with specifications, drawings and codes of
practice.

TOTAL CARRIED TO NEXT PAGE 0.00

Elect Phase 1 Page 41


NABLUS REHABILITATION CENTER - PHASE I ITB-2013-267

Description Unit Price Amount


Item Unit Qty
US$ US$
FORWARDED TOTAL 0.00
12.6 UPS Device
Supply, install, test and commission 6KVA [230]V UPS device.
1in/1out, includes charger and rectifier، static inverter، BUILT IN
batteries for feeding registration, 8 minutes operation with any needed No 1 0.00
racks and isolation transformer and all accessories and test operation.
Type Inform or equally approved

12.7 Lighting System


12.7.1 Supply, install, test and commission a complete lighting point including
all conductors, cables, conduits (PVC or galvanized), switches, push
buttons (type Legrand or equally approved), boxes, ceiling rose,
flexible connection, heat resistant cables and all other accessories, No 255 0.00
from the appropriate distribution board to the lighting point, as
specified and detailed on drawings. (points for Ground & Basement
floors)
12.7.2 Ditto as above, but for exits signs and emergency lights No 33 0.00
12.8 Light Fixture
Supply, install, test, fix and commission a complete lighting fixture,
including all supports, lamps, switches connections, suspensions,
clamps, switchgears, internal conductors and/or cables, and all other
accessories necessary to provide a complete fitting with all terminals,
as shown on the drawings( light fixture schedule) and in accordance
with the specifications and the engineer’s instructions. (Fixtues for
ground Floor only)

12.8.1 Type A No 16 0.00


12.8.2 Type A with charger and battery No 15 0.00
12.8.3 Type B No 33 0.00
12.8.4 Type B with charger and battery No 8 0.00
12.8.5 Type C No 3 0.00
12.8.6 Type C with charger and battery No 2 0.00
12.8.7 Type D No 5 0.00
12.8.10 Type G No 19 0.00
12.8.11 Type H No 22 0.00
12.8.12 Type H with charger and battery No 4 0.00
12.8.13 Type J (hidden light) MR 25 0.00
12.8.14 Type K No 13 0.00
12.8.15 Type L No 2 0.00
12.8.16 Type N No 3 0.00
12.8.17 Type O No 5 0.00
12.8.18 Type Q (exit) No 4 0.00
TOTAL CARRIED TO NEXT PAGE 0.00

Elect Phase 1 Page 42


NABLUS REHABILITATION CENTER - PHASE I ITB-2013-267

Description Unit Price Amount


Item Unit Qty
US$ US$
FORWARDED TOTAL 0.00
12.9 Telecommunication system

12.9.1 Supply, install, test and commission 50 pair telephone terminal board
(MLV) complete with all accessories needed to complete work, as No 1 0.00
specified and as detailed on drawings.

12.9.2 Supply, install, test and commission 20 pair telephone terminal


boards (LV) complete with all accessories needed, all necessary
double jumpers for incoming and outgoing connections to complete
No 1 0.00
work, 20 pair incoming cables from MLV, as specified and as detailed
on drawings for the followings:

12.9.3 Supply, install, test, and commission a complete telephone outlet


including all conduits, boxes (flush or surface mounted), 4 pair high
quality cables, outlet type Legrand or equally approved. According to No 16 0.00
specifications and drawings. All telephone outlets shall be numbered
in sequence.

12.9.4 Supply, install, test, and commission a complete data outlet


including all conduits, boxes (flush or surface mounted), high quality
cables S/FTP CAT6A cables , RG 45 Cat 6A modular outlet type
Datwyler or equally approved, and cable tray, According to No 22 0.00
specifications and drawings. All Data outlets shall be numbered in
sequence.

12.9.5 Supply, install, test, and commission a 19'' server rack cabinet (DC),
22U, 80cm depth, 60 cm width, type Estap or equally approved
including power strips, fans, all needed internal cables, cable ties,
No 1 0.00
cable management trays ( horizontal and vertical) , connections and all
accessories needed to complete the work as specified and as detailed
on drawings, and according to the Engineer's instructions.
12.9.6 Supply, install, test, and commission a 24 port patch panel type
Datwyler or equally approved including patch cord and all accessories
needed to complete the work. As specified and as detailed on No 1 0.00
drawings, and according to the Engineer's instructions.

12.9.7 Supply, install, test, and commission a complete satellite outlet


including all conduits, boxes (flush or surface mounted), high quality
cables, outlet type Legrand or equally approved. According to No 3 0.00
specifications and drawings.
12.9.8 Supply, install, test, and commission a complete satellite antenna
including dish, conduits, boxes, high quality cables and all accessories
LS 1 0.00
needed to complete work according to specifications and the
Engineer's instructions.
12.9.9 Supply, install, test, and commission Cascadable multiswitch with
13/16 outputs No 1 0.00

TOTAL CARRIED TO NEXT PAGE 0.00

Elect Phase 1 Page 43


NABLUS REHABILITATION CENTER - PHASE I ITB-2013-267

Description Unit Price Amount


Item Unit Qty
US$ US$
FORWARDED TOTAL 0.00
12.10 Fire Alarm & Voice Evacuation Systems

12.10.1 Supply, install, connect, test, operate and commission a fully recessed
addressable fire alarm control panel (4-loops) including all
equipments and accessories, batteries, charger, internal conductors
and/or cables, switches, fire rated cables connected to DB-UPS LS 1 0.00
..etc., the price includes also active repeater on the external door. In
accordance with the requirements of the specifications and as shown
on drawings.

12.10.2 Supply, install, test and commission an addressable fire alarm photo-
optical smoke detector including all conduits fixing, boxes, and
No 22 0.00
2x1.5mm2 high quality cables . According to specification and
drawings.
12.10.3 Supply, install, test and commission addressable fire alarm heat
detector including all rigid conduits fixing, boxes, and 2x1.5mm2 high No 1 0.00
quality cables. According to specification and drawings.
12.10.4 Supply, install, test and commission a flush mounted addressable fire
alarm manual pull station including all conduits fixing, boxes, and No 4 0.00
cables. According to specifications and drawings.
12.10.5 Supply, install, test and commission a fire alarm addressable
electronic sounder with flasher including all conduits fixing, boxes, and No 4 0.00
2x2.5mm2 cables. According to specifications and drawings.

12.10.6 Supply, install, test and commission a fire alarm addressable


electronic sounder IP66 with strobe including all conduits fixing, boxes,
and 2x2.5mm2 cables. According to specifications and drawings. No 1 0.00

12.10.7 Supply, install, test and commission a programmable auto dialer for
connection with local defense department with all needed wiring, No 1 0.00
programming etc., as per specifications and drawings.
12.10.8 Supply, install, test and commission fireman switch to cut off the
electricity in emergency including all conduits fixing, boxes, and No 1 0.00
cables. According to specifications and drawings.
12.10.9 Supply, install, test and commission voice command center including
voice command center, amplifiers, connections, microphones all
needed accessories to complete the job as per drawings, LS 1 0.00
specifications and Engineer’s instructions.

12.10.10 Supply, install, test and commission Voice Evacuation ceiling mounted
speaker, with tapping at 2,4,6 & 8W including all conduits fixing, No 6 0.00
boxes, and cable according to specifications and drawings.

12.10.11 Supply, install, test and commission fire man switch to cut off the
electricity in emergency including all conduits fixing, boxes, and No 1 0.00
cables. According to specifications and drawings.
12.11 CCTV System (Provisional Item)
12.11.1 Supply, install, connect, test, operate and commission a 32 Camera
Digital Video Recorder as 3xlogic DVR H.264 Series full hybrid
functionality, NTSC/Pal, support 4CIF resolution and Ethernet rack
mounted, including of all equipment, software, accessories, internal No 1 0.00
conductors, 32 channels DC power supply for camera with cables,
2TB HDD. According to specification and drawings.

12.11.2 Supply, install, test, operate and commission a complete 1/3.2” format
12/24 Volt CCD type mini dome day/night color camera complete with
varifocal 2.7-9 mm lenses with auto iris facility, FLK control, BLC, AGC,
IR super wide dynamic and white balance including as HLC-1NAD all No 13 0.00
conduits fixing, boxes, and high quality RG59 cables. According to
specification and drawings.

12.11.3 As above but external camera as HLC-79AD No 11 0.00


12.11.4 Supply, install, test, operate 42" LCD screen No 1 0.00
TOTAL CARRIED TO NEXT PAGE 0.00

Elect Phase 1 Page 44


NABLUS REHABILITATION CENTER - PHASE I ITB-2013-267

Description Unit Price Amount


Item Unit Qty
US$ US$
FORWARDED TOTAL 0.00
12.12 Low Voltage Systems First Fix
12.12.1 Nurse call system point including conduits, boxes and pull wire. No 25 0.00
12.12.2 Fire alarm point for basement including conduits, boxes and pull wire.
No 25 0.00

12.12.3 Voice evacuation point for basement including conduits, boxes and No 8 0.00
pull wire.
12.12.4 Camera point for basement including conduits, boxes and pull wire. No 4 0.00
12.12.5 Intrusion system point (points for motion detector, magnetic contacts No 22 0.00
and all other components…) including conduits, boxes and pull wire.
12.13 External Works
12.13.1 Power Manhole
Supply, install, connect, and construct 100x100x100 cm electrical
manhole including heavy-duty cast iron cover 25Ton, the work as No 1 0.00
shown on drawings, specifications and engineer approval.
12.13.2 Supply, install, test and commission 4” UPVC conduit from electrical
room to the nearest electrical pole from authority supply point including
excavation, backfilling and all civil works need to complete the work.
All shall be in accordance with the drawings, specification, codes of MR 50 0.00
practice and the highest prevailing standards of engineering.

12.13.3 Telephone Manhole


Supply, install, connect, and construct 80x80x80 cm telephone
manhole including heavy-duty cast iron 25Ton cover, the work as No 1 0.00
shown on drawings, specifications and engineer approval.
12.13.4 Supply, install, test and commission 2 x 3” rigged PVC conduit from
electrical room to the nearest telecommunication authority supply point
including excavation, backfilling and all civil works need to complete
the work. All shall be in accordance with the drawings, specification, MR 50 0.00
codes of practice and the highest prevailing standards of engineering.

12.14 FM200 System


12.14.1 Supply and install FM200 clean agent fire extinguisher cylinder, of 3 kg
capacity, UL approved, for Sub-MDB. The price includes SCH40
galvanized steel pipes network with all valves and fittings, shuttle
valve, pressure gauge switch, solenoid valve, safety valve, flexible
hose, discharge nozzles, control panel (of approved quality) for
operating fire fighting and alarm systems with all electrical
connections, smoke detectors, photo optical detectors and all
accessories needed for installation and commissioning the system. No 1 0.00
Note: The contractor should submit a UL flow calculation report
including design and shop drawings, from the original manufacturer,
for the system, in addition to all needed samples such as detectors,
and nozzles, to be checked and studied prior to supplying and
installing the system.

TOTAL CARRIED TO SUMMARY 0.00

Elect Phase 1 Page 45


NABLUS REHABILITATION CENTER - PHASE I ITB-2013-267

BILL No. 13 - MECHANICAL WORKS


Item No Item Description QTY Unit Unit Price
US$
13.1 Mechanical Works at Skelton Stage
13.1.1 Supply and Install ø3" pvc sleeves through external walls for main water
pipes No. 6

13.1.2 Floor Trap


First fix 4" Floor traps in basement floor slab. Price includes also all
drainage piping up to main pipe or manhole. No. 8.00
13.1.3 Clean Out
a First fix 4" clean out in basement floor slab as shown in drawings No. 5.00
b Ditto, but 6" clean Out No. 5.00
13.1.4 Sleeves Floor Trap
Supply and Install ø6" pvc sleeves through slabs of floors at locations
where the floor traps will be located . No. 1

13.1.5 Sleeves for wc


Supply and Install ø6" pvc sleeves through slabs of floors at locations
where the wc will be located and elbows for first fix of wc. The price No. 14.00
includes also all drainage piping up to main pipe or manhole.
13.1.6 Internal & Vertical Sanitary Pipes :
a Supply and install ø 4" drainage UPVC red pipes for buried network up to
external manholes with all required fittings and testing. Mr. 125.00
b Ditto, but 6" UPVC
Mr. 75.00
c Supply and Install ø6" pvc sleeves through external walls for rain and
sewage No. 2
d Ditto but 4" for rain water. Mr. 2
e Ditto but 3" for rain water. Mr. 2
13.1.7 Water &Fire reservoir
Supply and install all required for the first fix for the well. The price
includes overflow,vent,water inlets, fire inlets all as drawings and
specifications. LS 1.00
13.1.8 Grease Trap Interceptor Pit:
Supply and install all required for the first fix for the grease trap interceptor.
The price includes pipes sleeves connection to grease trap pit, all as
drawings and specifications. No. 1
TOTAL CARRIED TO NEXT PAGE

Mech Phase 1 Page 46


NABLUS REHABILITATION CENTER - PHASE I ITB-2013-267

Item No Item Description QTY Unit Unit Price


US$
FORWARDED TOTAL
13.2 Sanitary and Drainage Work
13.2.1 European Toilet
a Supply and install White Vitreous China European type wall hung toilet
No 2
complete with European made flush tank, including the following:
b 80X50cm mirror with aluminum frame No 2
c Hand dryer, 2000 WATT No 2
d Stainless steel paper towel Hanger No 2
e Heavy duty Soap dispenser No 2
f Seat hard cover No 2
g Water hose with flusher No 2
h Chrome plated angle valves No 2
13.2.2 Ditto as 13.2.1 (a - h), but for Special Needs including holding bar and all
other needed accessories type Pressalit or equivalent. No 7

13.2.3 Wash Basin


a Supply and install White Vitreous China Wash Basin, size (40 * 56) cm
complete with all fittings, valves, the price also includes the water mixer
and any other necessary parts as per drawings and specifications. No 2

b Ditto, but for Special Needs including holding bar and all other needed
accessories type Pressalit or equivalent. No 7

13.2.4 Kitchen Sink


Supply, install and commissioning of stainless steel double bowl kitchen
sink, from approved quality. Complete with chrome plated mixer for kitchen
sinks, supports, waste outlet, tail piece, P-trap chrome plated, chrome No 1
plated 13mm pipe as per drawings and specifications.
13.2.5 Shower accessories
Supply, install and commissioning of shower accessories for Special
Needs type Pressalit or equivalent, complete with shower head, diverter,
hand spring ,hose, bracket, and all accessories, waste outlet as shown in No 5
the drawings and specifications .
13.2.6 Floor Trap and Clean Outs
a Supply and install 4/2” PVC Floor Trap, (15*15) double chrome plated
cover one grated and one closed including collecting box and all other No 10
fittings needed as per the drawings and specifications .
b Ditto, but 4" clean Out. No 9
c Ditto, but 6" clean Out. No 1
13.2.7 UPVC Drainage Pipes
a Supply, installation, testing and commissioning of 2" UPVC drainage and
ventilation pipes down to manholes with all required fittings including
excavation, back filling, incasing with concrete and roof vent caps, MR 30
including connections as shown in drawings.

b Ditto but 4" MR 90


c Ditto but 6” External Sewers of UPVC pipes between manholes. Price to
include trench excavation, trench bottom leveling and preparation, bedding
in sand, supply of pipes, back filling with selected material, jointing all MR 85
fittings, testing, cleaning and all related works to complete as per
Drawings.

TOTAL CARRIED TO NEXT PAGE

Mech Phase 1 Page 47


NABLUS REHABILITATION CENTER - PHASE I ITB-2013-267

Item No Item Description QTY Unit Unit Price


US$
FORWARDED TOTAL

13.2.8 CPVC Drainage Pipes

Supply, installation, testing and commissioning of 2" CPVC (ceiling-


suspended and under the slab) for condensation from indoor air
conditioning system with all required fittings, hangers, including MR 60
connections as shown in drawings and in accordance to specifications.
13.2.9 Water Tanks
Supply and install water plastic tanks (heavy duty) of 1500 liters capacity,
domestic cold water system. The price include painted steel base, stop
valves, floating tank for each tank, connection with municipality and main
supply pipes through galvanized steel pipes. The price should also include No 2
water collector, galvanized hangers and supports of suitable type and size,
and all other fittings needed to complete the job.

13.2.10 Solar Panels


Supply, install and test of solar panel unit, of approved quality, with an
approximate size of 180*130cm. The price includes galvanized steel base,
connection of feed and hot water pipes with all fittings, Ice reducers, No 4
elbows, tees,…. as per engineer’s instructions and drawings.

13.2.11 Manholes
Supply and install precast Manholes of diameter Price to include
excavation, concrete works, back filling, cement plaster, benching, Cast
Iron medium cover and all necessary works to comply with drawings and
specifications.
a 60cm*60cm No 16
b 80cm*80cm No 6
c 100cm*100cm No 3
d 120cm*120cm No 3
e Drop Manhole No 1
13.2.12 Water Grills
First fix cast iron grills, average depth is 30cm and width 40cm. located on
drawings .Price includes upvc pipes connection to the existing pipe and
smooth sloped concrete bedding in drawing the length .All as shown in M.R. 2
drawings and specifications.

TOTAL CARRIED TO NEXT PAGE.

Mech Phase 1 Page 48


NABLUS REHABILITATION CENTER - PHASE I ITB-2013-267

Item No Item Description QTY Unit Unit Price


US$
FORWARDED TOTAL
Domestic Hot and Cold Water Works
13.2.13 Poly Propylene Pipes (PPR) Pipes
Supply and install P.P.R pipes for cold and hot water pipes (25bar) The
price includes the insulation and all other fittings as per drawings and
specifications.
a 20mm pipe Mr 90
b 25mm pipe Mr 90
c 32mm pipe Mr 50
13.2.14 XLPE cross-linked polyethylene
Supply, install, and commissioning of XLPE cross-linked polyethylene
pipes, for all branches between sanitary fixtures and manifolds. The price
includes the non-corrugated sleeves, and plastic box that contain the
elbow or injasa for fixing in the wall. And the brass elbow itself for the Mr 350
connection to angle valve, with flush chrome plated hole cover, 16mm
internal diameter, as in drawings and in accordance to engineering
instructions and specifications

13.2.15 Water Collectors


Supply and install of copper collector for domestic water the price includes
all fittings (vent, valves, on main line and branches),and the steel
cupboard and all other fittings as per drawings and specifications.
a 3/4" COLL(1 outlet) No 2
b 3/4" COLL(2outlets) No 5
c 3/4" COLL(3outlets) No 5
d 1" COLL(4outlets) No 1
e 1" COLL(8outlets) No 1
13.2.16 Water taps
Supply and install water taps as shown in drawings and specifications. No 1
13.2.17 Circulating Pumps
Supply and install, and commission circulating hot water pumps with direct
motor drive, complete with two gate valves one at the suction side and one
at the discharge side and pressure gauges on both sides of pump and
check valve connected on the discharge side and a strainer on the suction
side. The price shall include steel frame for concrete floating base, with
the electrical connections with the isolators and all control wires, and over
load protection and magnetic contactor for each pump as shown in
drawings, and approval of supervisor engineer. The specifications of
pumps are as follows:

* Pump P2 No 2
* Pump P4 No 1
* Pump P6 No 2
* Pump P8 No 2
13.2.18 Hot Water Storage Cylinder
Supply and install 300 Litres hot water -double skin- storage tank of seven
outlets,. The price should include the following: 15cm thick reinforced
concrete or steel base, shock absorbers, supplying and installing of
temperature and pressure gauges, stop valves, fittings, strainer, flow and No. 2
return pipes, flexible joints, and all accessories needed for completing the
work, according to plans and engineer’s instructions.

TOTAL CARRIED TO NEXT PAGE.

Mech Phase 1 Page 49


NABLUS REHABILITATION CENTER - PHASE I ITB-2013-267

Item No Item Description QTY Unit Unit Price


US$
FORWARDED TOTAL

Fire Fighting Works


13.2.19 Powder Extinguisher
Supply and install Portable Fire Extinguisher of 3Kg. powder capacity
each in Location as decided by the Engineer. The installation shall be
complete with brackets and it should be in accordance with the Civil No 6
Defense specification.

13.2.20 Fire Pipes

a Supply and install and commissioning of galvanized steel (schedule 40) 1


1/4" inch for fire cabinet including all required sleeves, gate valves, check
valves,strainers,rubber pressure regulators, automatic air vents, drain MR 15
cocks,elbows,T, with all necessary fittings and connections. All is
according to drawings and specifications.

b Ditto but 2" MR 60


13.2.21 Fire Cabinet
Supply and install 80*80*30 cm steel fire hose reel cabinet 2mm .The
cabinet should includes 2*15m hose, 2" nozzle, hose reel of 1" diameter
*25mm rubber hose with nossele,6kg powder fire extinguisher,1" ball valve No 2
,2" ball valve, and landing valve. All according to drawings and
specifications.

13.2.22 Siamese Connection


Supply and install Siamese connection with two coupling of 65mm
No 1

TOTAL CARRIED TO NEXT PAGE.

Mech Phase 1 Page 50


NABLUS REHABILITATION CENTER - PHASE I ITB-2013-267

Item No Item Description QTY Unit Unit Price


US$
FORWARDED TOTAL
HVAC Works
13.2.23 Duct
Supply, install galvanized air duct of varies thickness as required by
SMAGNA , the price including hanging, digging, wooden sleeves or frames
around duct passing through walls, splitter dampers and volume dampers, M2 50
and flexible connection where needed and all fittings.

13.2.24 FANS
Supply and install ducted in-line exhaust fan. The price includes vibration
isolators, galvanized adapter, flexible connection at fan inlet and outlet
and all accessories needed for installation and commissioning. The price
shall also include outdoor rain water gravity grille with insect mesh and
shutter, all according to the sizes shown on drawings. The fan capacity is
as follows:

* 120 L/s Air Flow @ 0.2" Static pressure No 1


13.2.25 Heat Reclaim (Recovery) Unit
Supply, install, and commission heat reclaim (heat exchanger) ventilation
unit of supply and exhaust air unit, complete with remote control, builders
work, hangers and supports, in addition to outdoor fresh and exhaust air
grilles, sizes as shown on drawings, and connection with duct works, all
according to drawings, and approval of supervisor engineer:

300 L/s Air Flow @ 100 Pa External Static Pressure No 1


13.2.26 Pre insulated duct
Supply and install pre insulated duct UL LISTED as per drawings and
specifications. The price includes volume dampers ,cladding minimum 0.6 m2 100
mm on roof and in external shaft.

TOTAL CARRIED TO NEXT PAGE.

Mech Phase 1 Page 51


NABLUS REHABILITATION CENTER - PHASE I ITB-2013-267

Item No Item Description QTY Unit Unit Price


US$
FORWARDED TOTAL
13.2.27 Grilles and Diffusers
Supply, install, and commission white anodized aluminum grills and
diffusers, complete with insulated (where required) box with neck,
connection with duct or AC unit through insulated flexible duct connection
of fire retardant type:

a 30X30cm (4-way diffusers) with register No 6


b 60X20cm (2-blades grille) with register No 5
c 70X25cm (2-blades grille) with register No 1
d 15X15cm (exhaust grille) with register No 9
e 2.5 m length linear diffuser (2slots) No 1
f 2.2 m length linear diffuser (2slots) No 1
g 1.8 m length linear diffuser (2slots)-curve type No 1
h 1.7 m length linear diffuser (2slots) No 2
k 60X60cm (return grille) No 11
m 30X30cm (return grille) No 1
13.2.28 Outdoor Variable refrigerant Flow (VRF)

Supply, install and commission outdoor Variable Refrigerant Flow (VRF)


heat pump air conditioning inverter set, based on refrigerant R410. The
price includes control system, galvanized steel bases, supplying and
installing insulated gas pipes network from outdoor units till the locations
of indoor units through shaft, using galvanized supports and fasteners, in
addition to branch fittings, centralized control panel and all accessories
needed to complete the job. The price shall also include electrical wirings
and connection to isolators. The specifications which is based on 36 oC
outdoor summer condition and 22 oC indoor condition, are as follows:
a 45 kW Cooling Capacity & 40 kW Heating Capacity No 1
b 29 kW Cooling Capacity & 26 kW Heating Capacity No 1
13.2.29 Indoor Variable refrigerant Flow (VRF)

Supply, install, and commission indoor VRF air conditioning units,


concealed ducted type, complete with room thermostat, condensing pump,
drain connection, builders work, electrical wirings and connections to a
specified socket, all according to drawings, and approval of supervisor
engineer. The selection of the units shall be based on medium fan speed
and on the temperature conditions mentioned above. The specifications of
the units are as follows:
a 10.5 kW Cooling Capacity & 580 L/s Air Flow No 1
b 9.5 kW Cooling Capacity & 530 L/s Air Flow No 1
c 8.5 kW Cooling Capacity & 500 L/s Air Flow No 1
d 7.5 kW Cooling Capacity & 400 L/s Air Flow No 2
e 4.0 kW Cooling Capacity & 220 L/s Air Flow No 1
f 3.5 kW Cooling Capacity & 180 L/s Air Flow No 6
13.2.30 Fresh Air Variable refrigerant Flow (VRF)
Ditto, but the units of fresh air type locatyedon roof and covered with
suitable steel protection. The unit shall have a filter of efficiency not less
than 80% as follows:
16 kW Cooling Capacity & 430 L/s Air Flow No 1
TOTAL CARRIED TO SUMMARY.

Mech Phase 1 Page 52


NABLUS REHABILITATION CENTER - PHASE I ITB-2013-267

Total Price
US$

0.00

0.00

0.00
0.00

0.00

0.00

0.00

0.00

0.00
0.00
0.00

0.00

0.00
0.00

Mech Phase 1 Page 53


NABLUS REHABILITATION CENTER - PHASE I ITB-2013-267

Total Price
US$
0.00

0.00

0.00
0.00
0.00
0.00
0.00
0.00
0.00

0.00

0.00

0.00

0.00

0.00

0.00

0.00
0.00

0.00

0.00

0.00

0.00

Mech Phase 1 Page 54


NABLUS REHABILITATION CENTER - PHASE I ITB-2013-267

Total Price
US$
0.00

0.00

0.00

0.00

0.00

0.00

0.00

0.00

0.00

0.00

0.00

Mech Phase 1 Page 55


NABLUS REHABILITATION CENTER - PHASE I ITB-2013-267

Total Price
US$
0.00

0.00
0.00
0.00

0.00

0.00
0.00
0.00
0.00
0.00

0.00

0.00
0.00
0.00
0.00

0.00

0.00

Mech Phase 1 Page 56


NABLUS REHABILITATION CENTER - PHASE I ITB-2013-267

Total Price
US$
0.00

0.00

0.00

0.00

0.00

0.00

0.00

Mech Phase 1 Page 57


NABLUS REHABILITATION CENTER - PHASE I ITB-2013-267

Total Price
US$
0.00

0.00

0.00

0.00

0.00

0.00

Mech Phase 1 Page 58


NABLUS REHABILITATION CENTER - PHASE I ITB-2013-267

Total Price
US$
0.00

0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00

0.00

0.00

0.00

0.00

0.00

0.00

0.00
0.00

0.00

0.00

Mech Phase 1 Page 59


NABLUS REHABILITATION CENTER - PHASE I

Summary

Bill No. Description Amount


US$
Bill No. 1 Excavation Works. 0.00
Bill No. 2 Concrete Works. 0.00
Bill No. 3 Steel Structure Works 0.00
Bill No. 4 Stone Works 0.00
Bill No. 5 Hollow Concrete Block 0.00
Bill No. 6 Plastering. 0.00
Bill No. 7 Tiling, Flooring and Marble works. 0.00
Bill No. 8 Carpentry and Joinery Works. 0.00
Bill No. 9 Metal and Aluminum Works. 0.00
Bill No. 10 False Ceiling & Painting Works. 0.00
Bill No. 11 Insulation, Roofing and Expansion and/or Seismic Joints. 0.00
Subtotal Civil Works 0.00
Bill No. 12 Subtotal Electrical Works 0.00
Bill No. 13 Subtotal Mechanical Works 0.00

Grand Total 0.00


Percentage % discount or addition
Net Grand Total

Note: All Prices Exclude VAT

The sum of : ____________________________________________________________________

Contractor: --------------------------------------------------------------

Signature: ---------------------------------------------------------------
Date: --------------------------------------------------------------------

Summary Page 60