Anda di halaman 1dari 1

CALCULATION SHEET NUMBER

     
PUMP CALCULATION SHEET TAG NO.          PAGE 1 OF 1
PROJECT NUMBER:          
CLIENT:           SERVICE:          
INSPECTION CODE:          
LOCATION:           MANUFACTURER:          
SELLER:          
PROJECT:           BY:           DATE:          
REVISION: A DATE:          
SYSTEM SKETCH

V-3 3", 600 ft equivalent length @ 2 psi/100 ft max


V-4600 V-5 P-3

8 ft V-4 20 ft

4" 100 ft equivalent length @0.5 psi/100 ft max From P-4601

V-2
V-1 T-3600

P-4600

CONDITIONS DISCHARGE PRESSURE NORMAL RATED


Liquid Pumped         Terminal Pressure, Psig 0 0
Plus Static Head, Psi                 
Pumping Temperature (PT) 60 °F =0.4335 x 20 Ft. x 1 SG 8.67 8.67
(PT)=
Specific Gravity @ PT 1 Plus Equipment & Other Losses, Psi
@         °F         Item:          18 18
Viscosity @ PT 1.1cp                         
@         °F                                 
Vapour Pressure @ PT Saturated Psia                         
@         °F         Psia                         
Atmospheric Pressure 12.6 Psia                         

CAPACITY Control Valve Loss, Psi                 


Gallons/Minute @ PT 22 Orifice Loss, Psi                 
Safety/Factor 10 %= 2.2 Piping Losses, Psi 12 13.33
Rated GPM @ PT 25 Net Discharge Pressure, Psig 38.67 40

SUCTION PRESSURE RATED MAX. DIFFERENTIAL PRESSURE RATED


Source Vessel Pressure, Psig 0 6 Discharge Pressure, Psig 40
Plus Static Head, Psi Suction Pressure, Psig 2.4
=0.4335 x 8 Ft. x 1 SG(PT) 3.47 5.6 Differential Pressure, Psi 37.6
Minus Piping Losses, Psi 0.5 0.5
Minus Other Losses, Psi 0.5 0.5 Differential Head, Feet
Suction Pressure, Psig 2.47 10.6 = 2.31 x 37.6 Psi =          
Psia 15.07 23.2 1 SG (PT) 87 Ft.

NET POSITIVE SUCTION HEAD AVAILABLE (NPSHA) ESTIMATED SHUTOFF PRESSURE


Minimum (Rated) Suction Pressure* 15 Psia Maximum Suction Pressure 10.6 Psig
Minus Vapour Pressure @ PT 12.6 Psia 120% of Differential Psi 45.1 Psi
NPSH at Pump Suction 2.4 Psia Est. Shutoff Pressure 55.7 Psig
= 2.31 x 2.4 Psia/ 1 SG (PT) 5.5 Feet
Less Contingency 2 Feet POWER REQUIREMENTS
NPSHA 3.5 Feet Hydraulic Horsepower
HHP = 25 GPM (PT) x 37.6 P
* Rated Suction Pressure should be based on the minimum static head 1714
from the Pump Suction Flange to the bottom of the Source Vessel = 0.55
(NOT to be normal operating level) or to the minimum operating level Brake Horsepower
for Sump Pump submergence. BHP = 0.55 HHP/ .75 Efficiency
= 0.73