Anda di halaman 1dari 1

Microprocessor Burner Controls

R8001 SLATE Combustion System

Microprocessor based integrated combustion management


system, in a modular format, that provides configurable safety
Dimensions Approximate
with programmable logic for automatic boiler sequencing, SLATE Base:
circulation pump control, fan control, electronic ignition, flame 6 3/32 in. Wide x 7 3/32 in High x 5 19/64 in. Deep
supervision, system status indication, firing rate control, load Weight oz. (g): 2.1 oz (60 g)
control and limit control. Provides level of safety, functional Ambient Temperature: -20°F to +150°F (-29°C to +66°C)
capability and features beyond conventional controls. Vibration: 0.5 G environment
• Modular concept that is DIN Rail mountable for easy assembly Frequency: 50/60 Hz (±10%)
• 24 VDC to 24 VAC to 240 VAC in one system SLATE Modules (does not include sub-base)
• Configurable safety modules include: Base, Burner Control, Flame 2 11/16 in. Wide x 7 3/32 in. High x 4 19/32 in. x 4 19/32 in Deep
Amp modules, Fuel Air Ratio and Limit Weight oz. (g): 16 oz (454 g)
• Programmable logic modules include: Analog I/O and Digital I/O Ambient Temperature: -20°F to +150°F (-29°C to +66°C)
modules, and Annunciation Vibration: 0.5 G environment
• Actuators that provide 50 in/lb and 150 in/lb in NEMA 1 or NEMA 4 Frequency: 50/60 Hz (±10%)
(300 and 900 in/lb available through Durastep Actuators from Maxon SLATE Sub-Base:
specifically configured for SLATE) 3 13/32 in. Wide x 7 7/32 in. High x 1 5/32 in Deep
• Function block programming via SLATE AX Tool Weight oz. (g): 5 oz (142 g)
• 2 Fuel capability Ambient Temperature: -20°F to +150°F (-29°C to +66°C)
• Valve Proving
SLATE Display
• BACNet, Modbus, and web services capability through SLATE Base
8 17/64 in. Wide x 4 51/64 in. High (panel mounted)
• 7 inch color touch screen display
Weight oz. (g): 21 oz (595 g)
SLATE Applications Ambient Temperature: +32°F to +158°F (0°C to +70°C)
• ModIndustrial and Commercial Burner Boiler Controls Humidity: 95% continuous non-condensing
• Air Handling
Approvals, Underwriters Laboratories: Listed US Canada File No.
• Drying Applications
MP286
• Automotive Paint Booths
Approvals, Factory Mutual: Approved
• Single Stage Furnaces and Kilns
Approvals, CE: pending July 2016
• And more
Approvals, ISO23552-1: pending July 2016
Product Number Description
Product Number Description
R8001M1150/U SLATE Low Torque Actuator- 150 in/lb torque size in NEMA
R8001A1001/U SLATE Base Module-Provides power and external 1 enclosure to be used with SLATE Fuel Air Ratio Module
communications (Modbus/TCP, BACnet MSTP or IP, and web (R8001C6001/U)
services), overall health, web based pages, event log and trend
logs R8001M4050/U SLATE Low Torque Actuator- 50 in/lb torque size in NEMA
4 enclosure to be used with SLATE Fuel Air Ratio Module
R8001B2001/U SLATE Burner Control Module-Flame safeguard controls, valve (R8001C6001/U)
proving, dual fuel capability, configurable safety, and safety relay
R8001M4150/U SLATE Low Torque Actuator- 150 in/lb torque size in NEMA
R8001S1071/U SLATE UV Flame Amp with Ampli-Check Module- responds to 4 enclosure to be used with SLATE Fuel Air Ratio Module
ultraviolet signal from an ultraviolet type flame detector. Used (R8001C6001/U)
with C7027 and C7035 detector series
R8001L8001/U SLATE Limit Module- 12 limit block capability. Choose from
R8001S1051/U SLATE UV Flame Amp with Shutter-Check Module-responds to high limit, low limit or dual track limit. Can monitor any sensor
ultraviolet signal from an ultraviolet type flame detector. Used or pair sensors.
with the C7061 detector series.
R8001U3001/U SLATE Digital I/O Module- Digital input/output module with up to
R8001V1091/U SLATE UV/Visible Flame Amp with Ampli-Check Module- 14 opto inputs or 6 relays.
responds to an ultraviolet/visible light signal from a UV/visible
light type flame detector. Used with the C7927, C7962 detector R8001D4001/U SLATE Analog I/O Module- Universal analog input/output
series. module with configurability
R8001V1031/U SLATE Rectification Flame Amp with Ampli-Check Module- R8001N7001/U SLATE Annunciator Module- Provides first out annunciation
responds a rectified signal from a rectification type flame R8001K5001/U SLATE 7 inch color touchscreen display
detector. Used with the C7000X detector series. SLATEAXTTOOL SLATE AX Tool for programming of the SLATE system,
R8001F1041/U SLATE Infrared Flame Amp with Ampli-Check Module- responds configuration of the safety modules and creating display
to an infrared signal from an infrared type flame detector to graphics
indicate the presence of flame. This flame amplifier is used with 32008001-002/U SLATE connector bag assembly that contains connectors for
the C7915 detector series sub-base for remote flame amplifier module or remote reset
R8001C6001/U SLATE Fuel Air Ratio Control Module- monitors and controls the button connections. This assembly also contains the 2 pin-
air fuel ratio for combustion applications power connector for the SLATE display
R8001M1050/U SLATE Low Torque Actuator- 50 in/lb torque size in NEMA 50096820-001/U SLATE Extension Cable. Allows for connection between one
1 enclosure to be used with SLATE Fuel Air Ratio Module SLATE systems and subsequent SLATE modules on another DIN
(R8001C6001/U) Rail for space savings in an electrical enclosure.

50 70-8911