VDS (V) rDS(on) () ID (A)
0.022 @ VGS = 10 V 7.5
Channel-1
0.030 @ VGS = 4.5 V 6.5
30
0.0135 @ VGS = 10 V 9.8
Channel-2
0.0175 @ VGS = 4.5 V 8.5
D1 D1 D2 D2
SO-8
S1 1 8 D1
G1 2 7 D1
G1 G2
S2 3 6 D2
G2 4 5 D2
S1 S2
Top View
N-Channel 1 N-Channel 2
MOSFET MOSFET
Notes
a. Surface Mounted on 1” x 1” FR4 Board.
Dynamicb
Ch-1 8.0 12
Total Gate Charge Qg
Ch
Channel-1
Channel
l1 Ch-2 23 34
VDS = 15 V, VGS = 5 V, ID = 7.5 A Ch-1 1.75
Gate-Source Charge Qgs nC
C
Channel-2 Ch-2 8.6
VDS = 15 V
V, VGS = 5 V,
V ID = –9.8
98A Ch-1 3.2
Gate-Drain Charge Qgd
Ch-2 7.2
Ch-1 10 20
Turn-On Delay Time td(on)
Ch-2 17 30
Ch
Channell1
Channel-1
VDD = 15 V, RL = 15 W Ch-1 5 10
Rise Time tr
ID ^ 1 A, VGEN = 10 V, RG = 6 W Ch-2 10 20
Channel-2 Ch-1 26 50
Turn-Off Delay Time td(off) V, RL = 15 W
VDD = 15 V ns
Ch-2 60 100
ID ^ 1 A, VGEN = 10 V, RG = 6 W
Ch-1 10 16
Fall Time tf
Ch-2 17 30
IF = 1.8 A, di/dt = 100 A/ms Ch-1 30 60
Source-Drain Reverse Recovery Time trr
IF = 1.8 A, di/dt = 100 mA/ms Ch-2 40 70
Notes
a. Pulse test; pulse width v 300 ms, duty cycle v 2%.
b. Guaranteed by design, not subject to production testing.
24 24
I D – Drain Current (A)
12 12
TC = 125C
6 6
25C
1V –55C
2V
0 0
0 2 4 6 8 10 0 0.5 1.0 1.5 2.0 2.5 3.0 3.5 4.0
0.04 800
DS(on) – On-Resistance ( )
C – Capacitance (pF)
Ciss
0.03 600
VGS = 4.5 V
Crss
0.01 200
r
0 0
0 6 12 18 24 30 0 6 12 18 24 30
8
1.4
(Normalized)
6
1.2
1.0
4
0.8
2
0.6
0 0.4
0 3 6 9 12 15 –50 –25 0 25 50 75 100 125 150
Qg – Total Gate Charge (nC) TJ – Junction Temperature (C)
Source-Drain Diode Forward Voltage On-Resistance vs. Gate-to-Source Voltage
40 0.10
DS(on) – On-Resistance ( W )
0.08
I S – Source Current (A)
TJ = 150C
10
0.06
TJ = 25C 0.04
ID = 7.5 A
0.02
r
1 0
0 0.2 0.4 0.6 0.8 1.0 1.2 1.4 0 2 4 6 8 10
0.4
80
0.2 ID = 250 mA
V GS(th) Variance (V)
Power (W)
–0.0 60
–0.2
40
–0.4
–0.6
20
–0.8
–1 0
–50 –25 0 25 50 75 100 125 150 0.001 0.01 0.1 1 10
TJ – Temperature (C)
Time (sec)
1
Normalized Effective Transient
0.2
Notes:
0.1
0.1 PDM
0.05
t1
t2
0.02 t1
1. Duty Cycle, D =
t2
2. Per Unit Base = RthJA = 89C/W
Normalized Thermal Transient Impedance, Junction-to-Foot
2
1
Normalized Effective Transient
0.2
0.1
0.1
0.05
0.02
Single Pulse
0.01
10–4 10–3 10–2 10–1 1 10
Square Wave Pulse Duration (sec)
VGS = 10 thru 4 V
32 40
I D – Drain Current (A)
24 30
TC = 125C
16 20
8 10 25C
2V 3V
–55C
0 0
0 2 4 6 8 10 0 0.5 1.0 1.5 2.0 2.5 3.0 3.5 4.0 4.5
3500 Ciss
VGS = 4.5 V
r DS(on) – On-Resistance ( )
0.016
C – Capacitance (pF)
2800
VGS = 10 V
0.012
2100
0.008
1400
Coss
0.004 Crss
700
0 0
0 8 16 24 32 40 0 6 12 18 24 30
VDS = 15 V VGS = 10 V
V GS – Gate-to-Source Voltage (V)
(Normalized)
6
1.2
4
1.0
2
0.8
0 0.6
0 9 18 27 36 45 –50 –25 0 25 50 75 100 125 150
0.04
I S – Source Current (A)
TJ = 150C
10
0.03
TJ = 25C 0.02
ID = 9.8 A
0.01
r
1 0
0 0.2 0.4 0.6 0.8 1.0 1.2 1.4 0 2 4 6 8 10
0.4
80
0.2 ID = 250 mA
V GS(th) Variance (V)
Power (W)
–0.0 60
–0.2
40
–0.4
–0.6
20
–0.8
–1 0
–50 –25 0 25 50 75 100 125 150 0.001 0.01 0.1 1 10
TJ – Temperature (C)
Time (sec)
1
Duty Cycle = 0.5
Normalized Effective Transient
Thermal Impedance
0.2 Notes:
0.1 PDM
0.1
t1
0.05 t2
t1
1. Duty Cycle, D =
t2
2. Per Unit Base = RthJA = 89C/W
0.02
3. TJM – TA = PDMZthJA(t)
4. Surface Mounted
Single Pulse
0.01
10–4 10–3 10–2 10–1 1 10 100 600
1
Normalized Effective Transient
0.2
0.1
0.1
0.05
0.02
Single Pulse
0.01
10–4 10–3 10–2 10–1 1 10
Square Wave Pulse Duration (sec)
Notice
Specifications of the products displayed herein are subject to change without notice. Vishay Intertechnology, Inc.,
or anyone on its behalf, assumes no responsibility or liability for any errors or inaccuracies.
Information contained herein is intended to provide a product description only. No license, express or implied, by
estoppel or otherwise, to any intellectual property rights is granted by this document. Except as provided in Vishay's
terms and conditions of sale for such products, Vishay assumes no liability whatsoever, and disclaims any express
or implied warranty, relating to sale and/or use of Vishay products including liability or warranties relating to fitness
for a particular purpose, merchantability, or infringement of any patent, copyright, or other intellectual property right.
The products shown herein are not designed for use in medical, life-saving, or life-sustaining applications.
Customers using or selling these products for use in such applications do so at their own risk and agree to fully
indemnify Vishay for any damages resulting from such improper use or sale.
8 7 6 5
E H
1 2 3 4
D h x 45
C
0.25 mm (Gage Plane)
A
All Leads
q 0.101 mm
e B A1 L
0.004"
MILLIMETERS INCHES
DIM Min Max Min Max
A 1.35 1.75 0.053 0.069
A1 0.10 0.20 0.004 0.008
B 0.35 0.51 0.014 0.020
C 0.19 0.25 0.0075 0.010
D 4.80 5.00 0.189 0.196
E 3.80 4.00 0.150 0.157
e 1.27 BSC 0.050 BSC
H 5.80 6.20 0.228 0.244
h 0.25 0.50 0.010 0.020
L 0.50 0.93 0.020 0.037
q 0° 8° 0° 8°
S 0.44 0.64 0.018 0.026
ECN: C-06527-Rev. I, 11-Sep-06
DWG: 5498
0.172
(4.369)
0.028
(0.711)
(6.248)
(3.861)
0.246
0.152
(1.194)
0.047
0.022 0.050
(0.559) (1.270)
Return to Index
Return to Index
APPLICATION NOTE
ALL PRODUCT, PRODUCT SPECIFICATIONS AND DATA ARE SUBJECT TO CHANGE WITHOUT NOTICE TO IMPROVE
RELIABILITY, FUNCTION OR DESIGN OR OTHERWISE.
Vishay Intertechnology, Inc., its affiliates, agents, and employees, and all persons acting on its or their behalf (collectively,
“Vishay”), disclaim any and all liability for any errors, inaccuracies or incompleteness contained in any datasheet or in any other
disclosure relating to any product.
Vishay makes no warranty, representation or guarantee regarding the suitability of the products for any particular purpose or
the continuing production of any product. To the maximum extent permitted by applicable law, Vishay disclaims (i) any and all
liability arising out of the application or use of any product, (ii) any and all liability, including without limitation special,
consequential or incidental damages, and (iii) any and all implied warranties, including warranties of fitness for particular
purpose, non-infringement and merchantability.
Statements regarding the suitability of products for certain types of applications are based on Vishay’s knowledge of
typical requirements that are often placed on Vishay products in generic applications. Such statements are not binding
statements about the suitability of products for a particular application. It is the customer’s responsibility to validate that a
particular product with the properties described in the product specification is suitable for use in a particular application.
Parameters provided in datasheets and / or specifications may vary in different applications and performance may vary over
time. All operating parameters, including typical parameters, must be validated for each customer application by the customer’s
technical experts. Product specifications do not expand or otherwise modify Vishay’s terms and conditions of purchase,
including but not limited to the warranty expressed therein.
Except as expressly indicated in writing, Vishay products are not designed for use in medical, life-saving, or life-sustaining
applications or for any other application in which the failure of the Vishay product could result in personal injury or death.
Customers using or selling Vishay products not expressly indicated for use in such applications do so at their own risk.
Please contact authorized Vishay personnel to obtain written terms and conditions regarding products designed for
such applications.
No license, express or implied, by estoppel or otherwise, to any intellectual property rights is granted by this document
or by any conduct of Vishay. Product names and markings noted herein may be trademarks of their respective owners.