Anda di halaman 1dari 4

SHC(S)

POWERED BY CUMMINS SERIES 50Hz

50Hz 1500rpm 3P 400/230V


STANDARDS:
Model S80HC(S)
Genset: GB/T2820—2009, ISO8528
Power(ESP) kVA/kW 80/64 Alternator: VDE0530, NEMA MG1-32, IEC34, AS1359
Diesel Engine: ISO3046, DIN6271
Power(PRP) kVA/kW 72/58
Standby Power: Continues running at variable load for duration of an
Rated Voltage V 400 emergency. No overload is permitted on these ratings.
Prime Power: Continues running at variable load for unlimited periods
Rated Current A 115
with 10% overload available for 1 hour in any 12 hour period.
Rated rotation speed r/min 1500
Power Factor 0.8

CONFIGURATION:
Frequency Hz 50 Standard: Engine, alternator, cooling system, Base frame
(excluding fuel tank), shock absorber, air inlet system,
Fuel Consumption L/h 16.2(100%) control box (including mains floating charge), plastic fan
blades (when the engine and water tank do not bring).
Phase No. 3-phase

insulation Grade H Optional: Base frame (including fuel tank), water jacket
heater, fuel water separator, fuel heater, fuel level sensor
4 (only supporting underframe tank), switch box (with switch),
Pole Numbe
power switch, the water level sensor, motor anti
condensation heater, automatic fueling system (only
Excitation Mode Self-excitation
supporting base frame including fuel tank), battery frame.
Panel Type Digital Panel
Accessories: Silencer, bellow, exhaust silencing system
Performance Grade G2/G3 accessories (with the matching engine), regular battery,
starting cord assembly, data of genset, random tool (with
the matching engine).

Guangzhou Wanon Electric & Machine Co.,Ltd.


Add: No.25 Lijun Road, Panyu District, Guangzhou City, Guangdong
Tel: +86-20-84873189 Fax: +86-20-84873189 E-mail: info@saonon.com
Engine:

Engine Manufacturer CUMMINS

Engine Mode 4BTA3.9-G11

Engine Type 4 Stroke; In-line; 4 Cylinder Diesel

Air intake way Turbocharged

Cyl. 4

Cylinder Bore mm 102

Stroke mm 120

Displacement L 3.9

Rated Power kW 70

Engine Compression Ration 17.3:1

Fuel System Electronic Governor / north oil pump PB

Cooling System Water cooled

Lubrication System Pressure + Splash

Starting System Electric

Fuel Type To conform to grade No.2-D per ASTM D975 or GB 252-2000

Lube oil brand 15W40-CH4 Upgrade

Capacity of cooling water L 26

Lube Capacity L 11

Starting Voltage V DC24

Alternator:

Alternator Manufacturer STAMFORD

Alternator Model UCI224F

Control System AVR

Insulation System Class H

Protection IP23
Alternator
Rated Power Factor 0.8

Stator Winding Double Layer Concentric

Temperature grade H

Voltage Regulation ±1.0%

Satisfying Standardization BS EN 60034、 BS5000、VDE 0530、NEMA MG1-32、IEC34、CSA C22.2-100、AS1359

Guangzhou Wanon Electric & Machine Co.,Ltd.


Add: No.25 Lijun Road, Panyu District, Guangzhou City, Guangdong
Tel: +86-20-84873189 Fax: +86-20-84873189 E-mail: info@saonon.com
Control System

DSE6020 DSE7320 DSE8610


DSE6020 module is indicated on a large back-lit DSE7320 is an Auto Mains (Utility) Failure Control The DSE8610 is an easy to use multi-generator
LC icon . Module suitable for a wide variety of single, diesel load share system ,designed to synchronise up
Display via an array of warning, electrical trip and or gas,gen-set applications. to 32 generators including electronic and
shutdown alarm . Monitoring an extensive number of engine non-electronic engines.
Monitoring engine speed, oil pressure, coolant parameters, the modules will display warnings, The DSE8610 monitors the generator and
indicates operational status and fault
temperature, frequency, voltage, current, power shutdown and engine status information on the
conditions, automatically starting or stopping
and fuel level. back-lit LCD screen, illuminated LEDs, remote PC
the engine on load demand or fault condition.
The modules give comprehensive engine and and via SMS text alerts (with external modem).
Using the DSE PC Configuration Suite Software
alternator protection. DSE7320 module include USB, RS232 and RS485 allows easy alteration of the operational
ports as well as dedicated DSENet® terminals for sequences, timers and alarms. With all
system expansion. communication ports capable of being active
at the same time, the DSE8610 is ideal for a
wide variety of demanding load share
applications.

KEY BENEFITS KEY BENEFITS KEY BENEFITS


•auto and manual function • auto and manual function • Comprehensive load share capabilities
•AMF and ATS function • AMF & ATS & Communication &Expansion • Configurable inputs (11)
•Engine idle control for starting & stopping • Engine parameters: speed, oil pressure, water •Configurable outputs (8)
•Engine run-time scheduler temperature, battery voltage, oil level%, running •Voltage measurement
•Generator/load power monitoring (kW, kV A, kV hours, start times and charging voltage. •Built-in governor and AVR control
Ar, pf) • Alternator parameters: frequency, three phase •kW overload alarms
•Generator/load current monitoring and protection voltage(L-L,L-N) and three phase current •Comprehensive electrical protection
•Comprehensive warning,electrical trip or •Power parameters: KVA、 KW、 PF 、KVAR、 •RS232 & RS485 remote communication
shutdown protection upon fault condition KWh、KVAH and KVARH •Modbus RTU
•CAN, MPU and alternator •PLC functionality
•Mains parameters: Frequency, three phase
•Fully configurable via the fascia or PC using USB •Multi event exercise time
voltage(L-L,L-N)
•1 alternative configuration •Back-lit LCD 4-line text display
•16 countries languages and can be editable
•3 engine maintenance alarms •Worldwide language support
Polish, German, French, Dutch, American English,
•4 configurable DC outputs •utomatic start/Manual start
Portugal, Swedish language, Thai Language,
•4 configurable analogue/digital inputs •Peak lopping
Turkish, Spain, Italian, Spain(Mexico) and Chinese
•6 configurable digital inputs •Sequential set start
and so on .
•Support for 0-10 V & 4-20 mA oil pressure •Manual voltage/frequency adjustment
•PLC Logical function ( up to 100)
sensors •R.O.C.O.F. and vector shift
•Engine, alternator and mains control & protection.
•LCD and LED alarm indication •Generator load demand
•Engine Speed, Engine Oil Pressure, Engine Water
•Configurable event log (50) •Automatic hours run balancing
Temperature, Battery Charger Voltage, Alternator
•Mains (Utility) de-coupling
Voltage & Current & Frequency, Mains voltage and
•Mains (Utility) de-coupling test mode
frequency.
•Dead bus sensing
•With RS232 & RS485 Communication ports.
•Bus failure detection
•Modbus RTU communication protocol.
•Direct governor and AVR contro
•3 alternative configuration
•Volts and frequency matching
( Eg: shift from 50HZ / 60HZ or Single/ Three
•kW and kVAr load sharing
phase output voltage)
•Configurable event log (250)
•Pre-set running hours( gen-set need start up
regularly and maintain)
•Pre-set maintenance period(Engine running 250
hours and need change the three filters)
•12 configurable inputs and 8 configurable outputs
•Configurable event log (250)

Guangzhou Wanon Electric & Machine Co.,Ltd.


Add: No.25 Lijun Road, Panyu District, Guangzhou City, Guangdong
Tel: +86-20-84873189 Fax: +86-20-84873189 E-mail: info@saonon.com
Open Type L mm 2150

Weight& Dimension: W mm 730

H mm 1400

Weight kg 800

mm 2300
Silent Type L

W mm 960
Weight& Dimension:
H mm 1350

Weight kg 1540

Local Distributor:
Local Distributor: Saonon reserves the right to make change in model,technical specifications.
Drawings can be used as reference,
include the optional components.
All the industrial designs have been patented.

Guangzhou Wanon Electric & Machine Co.,Ltd.


Add: No.25 Lijun Road, Panyu District, Guangzhou City, Guangdong
Tel: +86-20-84873189 Fax: +86-20-84873189 E-mail: info@saonon.com