5 Tendency Design:
In 1.5 design the baseline was to dedicate 1.5 Fiber for each plot/house , i.e for 2 plots = 3 fibers , for
4 plots = 6 fibers and on the basis of that total numbers fiber cables capacity , Total Number of FDH
and their ports capacity calculated and 100% area of New Nazimabad covered
One Level splitting of 2:64 purposed in FDH for Villas and 2 Level splitting ( 2:4/2:8 in FDH) for High
rise buildings and 2nd Level splitting ( 1:16 / 1:8 in FAT ) inside the building
In 1.5 design one Joint Enclosure was covering 4 to 8 plots with farest distance of last plot from the
Joint Enclosure was 40 Meters.
03 Rings purposed with 1+1 protection upto FDH level ,Higher capacity Feeder cables of 96/144F
purposed with 50% spare fiber cores capacity for future expansion and O&M purposes.
In distribution section 12,24,48 and 96F capacity cables purposed
Feeder duct route purposed at depth of 4 Feet with 4” Dia 1 Way HDPE Pipe having Feeder
Handholes size 3x4x5 ( Handhole size adjustable to 3x3x3 also per site situation)
Distribution Duct route purposed at depth of 3 Feet with 2” Dia 1 Way HDPE pipe having
distribution Handholes size 2x2x3
Drop duct of 1” Dia 1 Way purposed from Joint Enclosure/Handhole up to each customer house/plot
in same distribution trench to avoid frequent excavation for every customer connection in future.
Sections where Feeder and distribution duct get common , for those sections feeder duct route
specification followed
NAP stands for Network Access Point where Joint Enclosure placed to cover customers.
Total 26 FDH ( 25 FDH of 288 Ports and 1 FDH of 144 Ports ) purposed to cover whole New
Nazimabad
One OLT purposed in Central Office to feed all FDH.
Technical Assumptions in 2.0 Tendency Design:
In 2.0 design, baseline is set to dedicate 2.0 Fiber for each plot/house , i.e for 2 plots = 4 fibers , for 4
plots = 8 fibers and on the basis of that total numbers fiber cables capacity , Total Number of FDH and
their ports capacity calculated and 100% area of New Nazimabad covered
One Level splitting of 2:64 purposed in FDH for Villas and 2 Level splitting ( 2:4/2:8 in FDH) for High
rise buildings and 2nd Level splitting ( 1:16 / 1:8 in FAT ) inside the building
In 2.0 design one Joint Enclosure covering 8 to 12 plots with farest distance of last plot from the Joint
Enclosure 65-70 Meters.
03 Rings purposed with 1+1 protection upto FDH level, higher capacity feeder cables of 96F
purposed with 25% spare fiber cores capacity for future expansion and O&M purposes.
In distribution section 12,24,48 and 96F capacity cables purposed
Feeder duct route purposed at depth of 4 Feet with 4” Dia (1 Way) HDPE Pipe having Feeder
Handholes size 3x4x5 ( Handhole size adjustable to 3x3x3 also per site situation)
Distribution Duct route purposed at depth of 3 Feet with 2” Dia (1 Way) HDPE pipe having
distribution Handholes size 2x2x3
Drop duct of 1” Dia (1 Way) purposed from Joint Enclosure/Handhole upto each customer
house/plot in same distribution trench to avoid frequent excavation for every customer connection
in future.
Sections where Feeder and distribution duct get common , for those sections feeder duct route
specification followed
NAP stands for Network Access Point where Joint Enclosure placed to cover customers.
Total 33 FDH of 288 Ports purposed to cover whole New Nazimabad
One OLT purposed in Central Office to feed all FDH.