0 penilaian0% menganggap dokumen ini bermanfaat (0 suara)
34 tayangan2 halaman
The document describes the Mediwise Bubble CPAP System which provides dual temperature control of the chamber and airway. It has high and low alarms for the airway and chamber. The rotating pressure adjustment lever controls the CPAP pressure from 0 to 10 cmH2O. Accessories include nasal prongs in small, medium, and large sizes, a head immobilizer, and heated wire breathing circuits.
The document describes the Mediwise Bubble CPAP System which provides dual temperature control of the chamber and airway. It has high and low alarms for the airway and chamber. The rotating pressure adjustment lever controls the CPAP pressure from 0 to 10 cmH2O. Accessories include nasal prongs in small, medium, and large sizes, a head immobilizer, and heated wire breathing circuits.
The document describes the Mediwise Bubble CPAP System which provides dual temperature control of the chamber and airway. It has high and low alarms for the airway and chamber. The rotating pressure adjustment lever controls the CPAP pressure from 0 to 10 cmH2O. Accessories include nasal prongs in small, medium, and large sizes, a head immobilizer, and heated wire breathing circuits.
Dual Temp control both Chamber Bubble CPAP Generator
& Airway Rotating Pressure Adjustment Lever High/Low alarm both airway & chamber Gas discharge ports direct gas away Heater wire mode offer optimal humidity & less water condensation. 360 Swivel inlet connector
Technical Specifications: Water level adjustment port allows
Dimensions : W135 x D170 x H 156 mm water to be added or removed without Heater wire capacity: 60W max disconnecting expiratory circuit Heater plate capacity: 150W, 110? max Neonatal Delivery Unit with Heater Plate Overheat :Cutoff: 118±6? CPAP Pressure - 0 to 10 cmH2O Air-O2 Mixer Air Oxygen Blender Temperature Control: Invasive mode: Bubble CPAP Generator AVINA Neonatal Delivery Unit consists of Air Oxygen Blender is manufactured Chamber outlet 37? Airway 40? Air-O2 Flowmeter based Mixer, Pressure by Precision Medical, USA Noninvasive mode: Manometer, Pressure Limiting Valve. Chamber outlet 31? Airway 34? Air Oxygen Blender mixes Air and Servo Humidifier Air-O2 Mixer provides mixing of Air and Oxygen in proportion decided by the Oxygen from 21% to 100% decided by the knob Setting flow level of Air and Oxygen Flowmeter controls the flow of Mixed Flowmeter controls the flow of Air-O2 from Air from 0 to 15 lpm 0 to 15 lpm
Pressure Manometer displays the delivered
pressure at the baby’s end
MAP Valve is the user settable pressure
limiting valve which controls the maximum pressure to be delivered to the baby Respiratory Accesories Used to make the head of the infant stabilized so that cpap interface remains intact.
Adjustable to different sizes of head
Comfortable and easy to use
Ventilator breathing circuit attachment
also provided CPAP Interface Nasal Prongs Head Immobilizer Nasal Prongs are reusable, soft silicone make, comfortable and low resistance Medical Air Compressor Three Sizes Available - Small, Med, Large Power: 230VAC / 50Hz
Infant Bonnet is made up of Cotton, Output: 30 psi
and is latex free. It can be used for any Neonatal / (Optional) Head Gear is nylon Pediatric Ventilator or CPAP Machine make and latex free Flow Capacity: 0 to 40 lpm (Optional) Chin Strap is soft, and has split top design for better fixation Inbuilt Air and Water filter
Heated Wire Circuits
Reusable and Disposable Heated Wire Breathing Circuits and Non Heated Wire Circuits available