Calculo de la Poblacion:
Pf=𝑷𝒐(𝟏+𝒓)ˆ𝒕
Caudal de Infiltracion:
Qi1=𝑸𝒊𝒕∗(𝑵𝒃+𝑵𝒄)
Qi2=𝑸𝒊𝒕∗𝑳𝒐𝒏𝒈
Qi=𝑸𝒊𝟏+𝑸𝒊𝟐
Qi1 = 0.122 lt/seg
Qi2 = 1.383 lt/seg
Qi = 1.505 lt/seg
Qe=𝟏𝟎%∗𝑸𝒎𝒉
Qe = 0.485 lt/seg
Q2036=(𝑷𝒇∗𝑲𝒓∗𝒅𝒐𝒕∗𝟏𝟎𝟎𝟎)/𝟖𝟔𝟒𝟎𝟎
0.001950 m3/seg
Q2036 = 1.9498 lt/seg
Q1 = 0.0617 lt/seg
Q2 = 0.0779 lt/seg
Q3 = 0.0858 lt/seg
Q4 = 0.0988 lt/seg
Q5 = 0.0296 lt/seg
Q6 = 0.1194 lt/seg
Q7 = 0.0037 lt/seg
QT = 0.4769 lt/seg
0.0024 m3/seg
QE =
2.4267 lt/seg
Qmh=𝑲𝟐∗𝑸E
0.0049 m3/seg
Qmh =
4.8534 lt/seg
Caudal de Diseño:
Qd=𝑸𝒎𝒉+𝑸𝒆+𝑸𝒊
0.00684 m3/seg
Qd =
6.844 lt/seg
Caudal Unitario:
Qu=𝑸𝒅/𝑳𝒐𝒏𝒈
Qu = 0.00136 lt/seg*m
QR=𝑸𝒖∗𝑳𝒕𝒓𝒂𝒎𝒐
LT = 5,030.57 m
LE = 594.93 m
QR = 6.035 lt/seg
Qaa=∑ 𝑄𝑅
D=((𝑸𝒅∗𝒏)/(𝟎.𝟐𝟖𝟒𝟐∗𝑺)^(𝟏⁄𝟐) )^(𝟑⁄𝟖)
INGENIERIA DEL PROYECTO
CALCULO HIDRAULICO EMISOR
D=((𝑸𝒅∗𝒏)/(𝟎.𝟐𝟖𝟒𝟐∗𝑺)^(𝟏⁄𝟐) )^(𝟑⁄𝟖)
D= 0.120 m
D= 119.96 mm
D= 4.72 pulg
Diametro Comercial:
DN = 0.200 m
DN = 8.00 pulg
DN = 200 mm
e= 3.90 mm
Di = 192.20 mm
Calculo de la Velocidad:
Y/D = 0.75
A= 0.023 m2
P= 0.403 m
RH = 0.058 m
Velocidad (Manning):
0.4489 ∗ 𝐷𝑖 1000 ∗𝑆
𝑉=
𝑛
V= 1.03 m/seg
V=C* 𝑅𝐻
.
C= .
∗
V= 0.96 m/seg
Y= 0.14 m
. ∗ ∗
Qn=
0.024 m3/seg
Qn =
24.00 lt/seg
Pendiente Minima:
Relacion Vr / V:
Vr / V = 0.81
Velocidad Real:
Vr = 0.83 m/seg
Velocidad Critica:
Vc = 3.67 m/seg
Vc >>> Vr
Relacion Yr / D:
Yr/D = 0.36
Yr = 0.07 m
Relacion RHr / D:
RHr/D = 0.198
τ= 2.987 Pa