LAMPIRAN B
PERHITUNGAN
HP Steam ke Turbin
Stack Gas
LP Steam ke Turbin
HRSG
Air
Umpan
HRSG
Udara Keluar Exhaust
Kompresor Gas
Blowdown
HRGS
Flue Gas
GTG
Fuel Gas Ruang Bakar
(Gas Turbine
Generator)
Udara Keluar
Kompresor
Flue Gas
DATA AKTUAL
Dengan cara yang sama, mol tiap komponen fuel gas dapat dilihat
pada
tabel berikut:
Dengan cara yang sama, massa tiap komponen fuel gas dapat dilihat
pada tabel berikut:
79%
N2 suplai = x N2 Reaksi
21%
79%
= x 206929.66 kmol = 778449.69 kmol
21%
Udara Keluar
Kompresor
O2 = 206929.66 kg
N2 = 21796591.36 kg
Total = 22003521.03 kg
Flue Gas
Ruang Bakar
Fuel Gas
CO2 = 1238063.95 kg
O2 = 4966311.96 kg
CH4 = 336384.48 kg N2 = 21802511.62 kg
C2 H 6 = 40255.73 kg H2 O = 899228.37 kg
C3 H 8 = 22247.72 kg Total = 28906115.89 kg
i-C4H10 = 5255.73 kg
n-C4H10 = 6101.49 kg
i-C5H12 = 2981.85 kg
n-C5H12 = 2039.09 kg
C6H14 = 5694.38 kg
N2 = 5920.25 kg
CO₂ = 60894.53 kg
Total = 487775.25 kg
HP Steam ke
Turbin = 128.31 ton/3 jam
LP Steam ke
Turbin = 21.96 ton/3 jam HRSG Air Umpan
HRSG = 151.77 ton/3 jam
Exhaust
Gas = 947.40 ton/3 jam
CO₂ = 2.78 % (mol) Blowdown
O₂ = 15.34 % (mol) HRGS
N₂ = 76.95 % (mol)
H₂O = 4.94 % (mol)
Dari hasi perhitungan sebelumnya, didapat komposisi mol gas masuk HRSG
sebagai berikut,
Tabel 7. Komposisi Gas masuk HRSG
Komponen % Mol
CO₂ 2.78
O₂ 15.34
N₂ 76.95
H₂O 4.94
Total 100.00
Stack
Gas CO₂ = 40577.63 kg
O₂ = 162771.23 kg
HP Steam ke N₂ = 714578.87 kg
Turbin = 128310.00 kg H₂O = 29472.27 kg
Total = 947400.00 kg
LP Steam ke
Turbin = 21960.00 kg HRSG
Air Umpan HRSG
= 151770.00 kg
Exhaust
Gas CO₂ = 40577.63 kg
O₂ = 162771.23 kg Blowdown
N₂ = 714578.87 kg HRGS = 1500.00 kg
H₂O = 29472.27 kg
Total = 947400.00 kg
Stack Gas
(Q5) T = 103.32 °C
HP Steam ke
T = 511.14 °C Turbin (Q3.2)
P = 4.50 MPa
Exhaust
Gas (Q1) T = 576.91 °C
CO₂ = 2.78 % (mol)
Blowdown
O₂ = 15.34 % (mol) HRGS (Q4)
N₂ = 76.95 % (mol) T = 250.22 °C
H₂O = 4.94 % (mol)
TIN = 576.91 °C
= 849.91 K
Tref = 28.70 °C
= 301.70 K
Tabel 11. Komponen Exhaust Gas Masuk HRSG
Komponen kmol % mol BM (kg/kmol) Tin (°K) Tref (°K)
CO₂ 922.22 2.78 44.00
849.91 301.70
106
B C
Cp = A + (T2+T1) + (T22+T2T1+T12)
2 3
1.01E-02 -3.42E-06
Cp CO2 = 6.339 + x 1151.61 +
2 3
x 1069788
= 32745937.70 Kj
2914.38 - 2922.60
= 2922.60 + x ( 0.33 - 0.3 )
0.50 - 0.30
109
= 2921.36 Kj/kg
x 346175.38
Dengan cara yang sama diatas, hasil perhitungan panas komponen O₂,
N₂, dan H₂O dapat dilihat pada tabel 31 dibawah ini
Tabel 21. Panas Sensibel Gas keluar HRSG unit 2
Cpm Q
Komponen Kmol Δt
(Kcal/kmol °K) (Kcal)
CO₂ 922.22 9.38 645665.81
O₂ 5086.60 7.07 2685279.24
74.62
N₂ 25520.67 6.92 13177973.62
H₂O 1637.35 8.04 981865.99
Kalor sensibel gas masuk HRSG 17490784.65
jadi, panas sensibel gas masuk HRSG
= 17490784.65 Kcal x 4.184 kJ
1 kcal
= 73181442.98 KJ
h. Q 6 (panas Konduksi)
TIN = 576.91 °C
Tref = 28.70 °C
L = 9.50 m
A = 121.96 m²
k = 43.00 W/m.°C
k x A x (Tin - Treff) (Sumber: Kern, 1965)
Q =
L
43.00 W/m.°C x 121.96 m² x (576.91 - 28.70) °C
=
9.50 m
Q = 302633.04 W
3600 s 1 kJ
Q = 302633.04 J/s
1 jam 1000
Q = 1089478.95 kJ/jam x 3 jam (basis)
= 3268436.84 kJ
i. Q 7 (Panas Konveksi)
TIN = 576.91 °C
Tref = 28.70 °C
114
d = 5 inch = 0.1270 m
A = 121.96 m²
h = 21.80 kkal/m².°C
Q = h x A x (Tin - Treff) (Sumber: Kern, 1965)
η = Qsteam - Qumpan
x 100 %
Qgas suplai
= ( 510396291.37 - 32745937.70 ) x 100 %
115
567567875.19 kJ
= 84.16 %
Stack Gas
(Q5) T 103.32 °C
=
HP Steam ke Q5.1 = 73181442.98 kJ
T = 511.14 °C Turbin (Q3.2)
P = 4.50 MPa
Q3.2 = 444613418.95 kJ
Stack Gas
(E2) T = 103.32 °C
HP Steam ke
T = 511.14 °C Turbin (E3.2)
P = 4.50 MPa
LP Steam ke
T = 227.92 °C Turbin (E4.1) Air Umpan Masuk
HRSG
HRSG (E3)
P = 0.33 MPa
T = 51.54 °C
Exhaust
Gas (E1) T = 576.91 °C
CO₂ = 2.78 % (mol) Blowdown
O₂ = 15.34 % (mol) HRGS (E5)
N₂ = 76.95 % (mol) T = 250.22 °C
H₂O = 4.94 % (mol)
Dengan cara yang sama hasil perhitungan untuk entalpi dan entropi
komponen O2, N2, dan H2O dapat dilihat pada tabel L.28 buku
termodinamika.
Tabel 24. Harga Entalpi dan Entropi Exhaust gas masuk HRSG
hi s°i
Komponen
(kJ/kmol) (kJ/kmol.K)
CO2 34768.29 260.55
O2 26214.93 237.86
N2 25289.14 222.82
H2O 29842.45 226.05
Dengan cara yang sama hasil perhitungan untuk entalpi dan entropi
komponen O2, N2, dan H2O dapat dilihat pada tabel L.28 buku
termodinamika.
Tabel 26. Harga Entalpi dan Entropi Stack gas keluar HRSG
hi s°i
Komponen
(kJ/kmol) (kJ/kmol.K)
CO2 12403.33 222.73
O2 10998.60 211.93
N2 11516.34 198.29
H2O 12546.51 196.59
H 2O
310 10302 190.03
Dengan cara yang sama hasil perhitungan untuk entalpi dan entropi
komponen O2, N2, dan H2O dapat dilihat pada tabel L.28 buku
termodinamika.
Tabel 28. Harga Entalpi dan Entropi Stack gas keluar HRSG Exhaust
hi s°i Gas (E1)
Komponen
(kJ/kmol) (kJ/kmol.K)
CO2 9494.92 214.12
O2 8785.98 205.38
N2 8772.47 191.84
H2O 10023.12 189.12
(230.23 - 209.32)
h2 = 209.32 kJ/kg + 51.54 - 50
(55 - 50)
= 215.76 kJ/kg
(0.8 - 0.7)
s2 = 0.70 kJ/kg.K + 51.54 - 50
(55 - 50)
= 0.72 kJ/kg.K
Untuk menghitung entalpi dan entropi uap dilakukan tiga kali interpolasi pad
P = 0.33 MPa dan T = 227.92 °C Di dapatkan entalpi dari interpolasi
sebesar h = 2921.36 kJ/kg Sedangakan entropi didapat dari interpolasi
Untuk menghitung entalpi dan entropi uap dilakukan tiga kali interpolasi pad
P = 4.50 MPa dan T = 511.14 °C Di dapatkan entalpi dari interpolasi
sebesar h = 3465.15 kJ/kg Sedangakan entropi didapat dari interpolasi
4 540 7.2056
500 6.8803
6 540 6.9999
### - ###
h2 = 1085.40 kJ/kg + 250.22 - 250
(260 - 250)
= 1086.48 kJ/kg
(2.9 - 2.8)
s2 = 2.79 kJ/kg.K + 250.22 - 250
(260 - 250)
= 2.79 kJ/kg.K
i. Menghitung fraksi mol komponen
Perhitungan fraksi mol komponen
xi = (Sumber:Hougen, 1954)
( 28.00 kg/kmol
)) + ( 0.04937
= 171697329.71 kJ/hr
1 hr 1 MW
= 171697329.71 KJ/hr = 47.69 MW
3600 s 1000 kj/s
Stack Gas
(E2) T = 103.32 °C
HP Steam ke E2 = 6.33 MW
T = 511.14 °C Turbin (Q4.2)
P = 4.50 MPa
Q3.2 = 47.69 MW