CAESAR II 2018 Ver: 10.00.00.7700 Date: 05-Jun-19 6:40:41 PM
Database: P-5283A API610 APP-F.C2eDB Name: API-610_P-5283A_ID_1
Pump Input
Description
Existing Pumps - P-5283A
Equipment ID 1
Label P-5283A
Center Line X Cosine 0.00
Center Line Z Cosine 1.00
Allowable Load Multiplier 2.00
Is Vertical Inline Pump No
Is Z-Axis Up No
Nozzle Input
Nozzle Job Path
Type
Suction P:\DEB\E-DE\E-DE-PP\01_PROJECT\01.1_PROJECT\2018\32_INSTALL
HEAT FACILITY IN FO TANK PROJECT_CRS-LR(DETAIL
DESIGN)\23_STRESS ANALYSIS\3_CII\REV_F1\CA-
0001_FO_SUC\CII\CA-0001_F1._P
Discharge P:\DEB\E-DE\E-DE-PP\01_PROJECT\01.1_PROJECT\2018\32_INSTALL
HEAT FACILITY IN FO TANK PROJECT_CRS-LR(DETAIL
DESIGN)\23_STRESS ANALYSIS\3_CII\REV_F1\CA-
0001_FO_SUC\CII\CA-0001_F1._P
1 of 5
CAESAR II ANALYSIS REPORT: API 610 2010 - Centrifugal Pumps (11th Ed.)
CAESAR II 2018 Ver: 10.00.00.7700 Date: 05-Jun-19 6:40:41 PM
Database: P-5283A API610 APP-F.C2eDB Name: API-610_P-5283A_ID_1
2 of 5
CAESAR II ANALYSIS REPORT: API 610 2010 - Centrifugal Pumps (11th Ed.)
CAESAR II 2018 Ver: 10.00.00.7700 Date: 05-Jun-19 6:40:41 PM
Database: P-5283A API610 APP-F.C2eDB Name: API-610_P-5283A_ID_1
3 of 5
CAESAR II ANALYSIS REPORT: API 610 2010 - Centrifugal Pumps (11th Ed.)
CAESAR II 2018 Ver: 10.00.00.7700 Date: 05-Jun-19 6:40:41 PM
Database: P-5283A API610 APP-F.C2eDB Name: API-610_P-5283A_ID_1
4 of 5
CAESAR II ANALYSIS REPORT: API 610 2010 - Centrifugal Pumps (11th Ed.)
CAESAR II 2018 Ver: 10.00.00.7700 Date: 05-Jun-19 6:40:41 PM
Database: P-5283A API610 APP-F.C2eDB Name: API-610_P-5283A_ID_1
Output Summary - Check of Combined Conditions F.1, F.2, F.3, F.4, F.5
Note: The Overall Status on the Output Summary for the pump analysis can pass, even if
the Table 5 limits are exceeded.
5 of 5