Product Summary
The SGM7001 sensors are Sensirion’s digital gas flow The standard volume flow (“mass flow”) output and I2C
meter modules designed for residential natural gas digital interface make this sensor extremely suitable for
metering applications. They measure the standard smart gas metering applications.
volume flow of natural gas independent of
temperature and pressure. The outstanding performance of these sensors is based
on Sensirion’s patented CMOSens® Technology, which
Gas meters with SGM7001 as core metrological unit can combines the sensor element, signal processing and
fulfill international accuracy and reliability standards digital calibration on a single microchip.
defined in EN1359 and EN14236. The patented design of
the flow channel and the patented pulsed measurement The well-proven CMOSens® Technology is perfectly
system ensure robust and reliable flow measurements suited for high-quality mass production and is an ideal
under demanding working conditions and under low choice for high-volume residential gas metering
power consumption. applications.
The sensor chip Design and build the gas meter housing
Ensure correct mounting and communication
The SGM7001 gas flow meter modules feature Sensirion’s Fine-tune calibration of the meter in air only
state-of-the-art CMOSens® flow chip. CMOSens® flow
chips are used in products for dedicated medical and Test meter in air only
automotive applications and sold worldwide in millions of Every SGM7001 sensor is individually pre-calibrated,
pieces per year. linearized and temperature compensated with air and a
surrogate gas of methane. Natural gas type family has to
The CMOSens® chip not only contains a thermal mass be known (Wobbe index range, e.g. either H- or L-gas) for
flow sensor element, but also the amplifier, A/D converter, automatic gas quality compensation to work.
calibration memory, digital signal processing circuitry, and
interface. Due to seamless integration of signal acquisition The customer needs to fine-adjust meter calibration in air
and processing on the single silicon die, significant only. No further calibration or testing with natural gas on
performance, reliability and cost benefits are achieved. the customer side is needed. Sensirion provides
consulting and support regarding fine-adjustment of
calibration.
www.sensirion.com 1/7
1. Sensor Performance1
Sensor performance is described for fine-adjusted product in template gas meter housing. Please note that a sensor that is
pre-calibrated only but not fine-adjusted may not meet specifications in this data sheet.
4 One measurement value is specified for an average of at least ten consecutive acquisitions. The value measured with a single acquisition (one single data acquisition) may
be outside the specified accuracy range.
www.sensirion.com 2/7
1.1.1 Initial accuracy over temperature4
For meters with temperature compensation, the norm allows additional +0.5% m.v. in the temperature range 0° – 30°C.
Outside 0° – 30°C, the norm allows additional +0.5% m.v./10°C. The initial accuracy values over temperature are listed in the
table below. Please note that the specified values are valid only after fine-adjustment has been performed.
1.2 Repeatability
Repeatability at static flow of subsequent measurements4.
www.sensirion.com 3/7
2. Electrical Specifications
2.1 Operating voltage
2.2 Interface
Digital 2-wire interface (standard I2C) with bus clock frequency of 100 kHz (Maximum 400 kHz)
Default I2C address: 64 (binary 1000 000)
www.sensirion.com 4/7
3. Mechanical Specifications
3.2 Connector
Connector type: JST-B4B-ZR-SM4-TFT:
Flow direction
www.sensirion.com 5/7
3.3.1 Mounting place
Sensor is designed to be placed at gas meter outlet.
3.6 Weight
Less than 30 g.
Revision history
Date Author Version Changes
03.09.2014 APE 1 First release
19.02.2015 APE 2 Adjustment of drawings and mounting information, general introduction changed
24.02.2015 APE 2.1 Major review
www.sensirion.com 6/7
Important Notices
Warning, personal injury This warranty does not apply to any equipment which has not been
installed and used within the specifications recommended by
Do not use this product as safety or emergency stop devices or in SENSIRION for the intended and proper use of the equipment.
any other application where failure of the product could result in EXCEPT FOR THE WARRANTIES EXPRESSLY SET FORTH
personal injury (including death). Do not use this product for HEREIN, SENSIRION MAKES NO WARRANTIES, EITHER EXPRESS
applications other than its intended and authorized use. Before OR IMPLIED, WITH RESPECT TO THE PRODUCT. ANY AND ALL
installing, handling, using or servicing this product, please WARRANTIES, INCLUDING WITHOUT LIMITATION, WARRANTIES
consult the datasheet and application notes. Failure to comply OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR
with these instructions could result in death or serious injury. PURPOSE, ARE EXPRESSLY EXCLUDED AND DECLINED.
If the Buyer shall purchase or use SENSIRION products for any SENSIRION is only liable for defects of this product arising under the
unintended or unauthorized application, Buyer shall defend, indemnify conditions of operation provided for in the datasheet and proper use of
and hold harmless SENSIRION and its officers, employees, the goods. SENSIRION explicitly disclaims all warranties, express or
subsidiaries, affiliates and distributors against all claims, costs, implied, for any period during which the goods are operated or stored
damages and expenses, and reasonable attorney fees arising out of, not in accordance with the technical specifications.
directly or indirectly, any claim of personal injury or death associated
with such unintended or unauthorized use, even if SENSIRION shall be SENSIRION does not assume any liability arising out of any application
allegedly negligent with respect to the design or the manufacture of the or use of any product or circuit and specifically disclaims any and all
product. liability, including without limitation consequential or incidental damages.
All operating parameters, including without limitation recommended
ESD Precautions parameters, must be validated for each customer’s applications by
The inherent design of this component causes it to be sensitive to customer’s technical experts. Recommended parameters can and do
electrostatic discharge (ESD). To prevent ESD-induced damage and/or vary in different applications.
degradation, take customary and statutory ESD precautions when SENSIRION reserves the right, without further notice, (i) to change the
handling this product. product specifications and/or the information in this document and (ii) to
See application note “Handling Instructions” for more information. improve reliability, functions and design of this product.
phone: +41 44 306 40 00 Sensirion Japan Co. Ltd. Sensirion China Co. Ltd.
fax: +41 44 306 40 30 phone: +81 3 3444 4940 phone: +86 755 8252 1501
info@sensirion.com info@sensirion.co.jp info@sensirion.com.cn
www.sensirion.com www.sensirion.co.jp www.sensirion.com.cn
Sensirion AG (Germany)
phone: +41 44 927 11 66 To find your local representative, please visit www.sensirion.com/contact
info@sensirion.com
www.sensirion.com 7/7