Anda di halaman 1dari 1

FOR CONSTRUCTION

NOTES:
FOR FINAL BALCONIES LOCATION AND SIZES, AS WELL AS THE LOCATION OF OPERABLE WINDOWS AND DOORS - REFERENCE IS TO BE MADE TO THE
ARCHITECTURAL PACKAGE.

SD1a SINGLE LEAF SOLID SWING DOOR SD2 SINGLE LEAF HOLLOW SWING DOOR
FR 60 min

170

170
20

VENEER FINISH HINGES


HINGES
ON MDF BACKING
SD1a STAINED TO MATCH
APPROVED SAMPLE HINGES
SD1a
1000
SD2
1000

2200 DOOR HEIGHT


DOOR WIDTH
DOOR WIDTH HINGES
DOOR VIEWER DOOR VIEWER

2250 STRUCTURAL OPENING


2250 STRUCTURAL OPENING

2250 STRUCTURAL OPENING


SGN

2200 DOOR HEIGHT


2200 DOOR HEIGHT

100
900
2390

2280
DOOR WIDTH

2280
DOOR BELL

HINGES HINGES
60 300

2220
KEY PLAN
1500

1500
VENEER FINISH
ON MDF BACKING
STAINED TO MATCH
APPROVED SAMPLE VENEER FINISH ON
1000

1000

1000
CHIPBOARD CORE
BACKING STAINED
10MM STAINLESS
TO APPROVED SAMPLE
STEEL REVEALS PLOT BOUNDARY LINE PLOT BOUNDARY LINE

TILE SKIRTING HINGES


AS SCHEDULED HINGES

50 1000 50 50 1000 50 TILE SKIRTING 900


TILE SKIRTING
AS SCHEDULED 50
1100 1100 AS SCHEDULED 1000 50 HINGES
STRUCTURAL OPENING STRUCTURAL OPENING STRUCTURAL OPENING
60 1040 60 60 300 60 1040 60

A B C
940
1160 1160 60 60

DET
05

02 DOOR ELEVATION - CORRIDOR SIDE 03 DOOR ELEVATION - APARTMENT SIDE 02 DOOR ELEVATION
ELE Scale: 1:20 @ A0 ELE Scale: 1:20 @ A0 ELE Scale: 1:20 @ A0 03 DOOR SECTION 02 DOOR ELEVATION 03 DOOR SECTION 02 DOOR ELEVATION
ELE Scale: 1:20 @ A0 ELE Scale: 1:20 @ A0 ELE Scale: 1:20 @ A0 ELE Scale: 1:20 @ A0
PLOT BOUNDARY LINE

DOOR
STOPPER DOOR
STOPPER
HINGES
HINGES
300

900

300
CLEAR OPENING
AS PER PLAN
AS PER PLAN
4 24/01/17 As Clouded JM
200

200

SD2
VARIES
1000
3 28/08/16 Tender Addendum JM
60

50 CLEAR OPENING 50 50 900 50


1100 1000
STRUCTURAL OPENING DOOR BELL STRUCTURAL OPENING 2 15/06/16 100 % Detailed Design JM
60 1040 60 60 300 60 940 60
1160 SGN 1060
1 28/05/16 100 % Detailed Design JM
100 NOTES:
- HINGES TO BE FIXED AS PER JOINERY
NOTES:
- HINGES TO BE FIXED AS PER JOINERY 0 31/07/15 Approved Issue JM
01 DOOR PLAN CONTRACTOR RECOMMENDATION
01 DOOR PLAN CONTRACTOR RECOMMENDATION
01 DOOR PLAN 01 DOOR PLAN
PL Scale: 1:20 @ A0
CORRIDOR SIDE
- ALL DOORS TO MEET ACOUSTICAL
STANDARDS AS PER ACOUSTICAL REPORT PL Scale: 1:20 @ A0
ACCORDING
- ALL DOORS
TO WET
TO MEET
AREA ACOUSTICAL
CONDITIONS AS PER
STANDARDS AS PER ACOUSTICAL REPORT PL Scale: 1:20 @ A0 PL Scale: 1:20 @ A0 Revision Date Revision Subject Approved
PROVIDED BY SPECIALIST PROVIDED BY SPECIALIST
Job #
Designed
B.P.
SD3 SD5 SINGLE LEAF HOLLOW SWING DOOR SD4a DOUBLE LEAF HOLLOW SWING DOOR SD10 SINGLE LEAF HOLLOW SLIDING DOOR D14114-0100D Drawn M.P.
Date
24-01-2017 Checked B.B.
Scale
- Approved
J.M.
HINGES
SD3
SD3 VENEER FINISH ON MR
CHIPBOARD CORE
BACKING STAINED
Project Name:
TO APPROVED SAMPLE
SD5
SD5
2250 STRUCTURAL OPENING

VENEER FINISHON ON
CHIPBOARD CORE HINGES
800 BACKING STAINED

MBR MULBERRY
50 DOOR WIDTH TO APPROVED SAMPLE VENEER FINISH ON MR
SD4a
2280

CHIPBOARD CORE
BACKING
STAINED TO MATCH
HINGES 700 APPROVED SAMPLE
2200 DOOR HIEGHT

2470 STRUCTURAL OPENING

50 DOOR WIDTH 50

PHASE III
2420 DOOR HEIGHT
2500

EQ EQ
1000

HINGES

HINGES

FRENCH DOORS
N
1000

TILE SKIRTING
800
AS SCHEDULED
50 50
900
MULBERRY PHASE III
STRUCTURAL OPENING SITE (PA-17_04)
30,859.09
SQM.

840 HINGES AL KHAIL ROAD

60 60

TILE SKIRTING
50 700
800 STRUCTURAL OPENING
50
AS SCHEDULED PLOT NO. : PROPOSED
COMMERCIAL

-
DEVELOPMENT

60 370 370 60

860
LOCATION :
DET
-
02 DOOR ELEVATION 02 DOOR ELEVATION 04 02 DOOR ELEVATION
ELE Scale: 1:20 @ A0 ELE Scale: 1:20 @ A0 ELE Scale: 1:20 @ A0
DOOR
STOPPER
900
CLIENT: Emaar Properties PJSC
HINGES
HINGES HINGES 40 CLEAR OPENING 40 P.O.Box 9440
300

AS PER PLAN
800
CLEAR OPENING Dubai
125 50 63

AS PER PLAN
AS PER PLAN SD10
SD3 SD5 United Arab Emirates
AS PER PLAN
AS PER PLAN 700
50 800 50
50 CLEAR OPENING 50 50 1000 50
900 1100 STRUCTURAL OPENING
STRUCTURAL OPENING 800
STRUCTURAL OPENING 1140 OWNER: Emaar Properties PJSC
NOTES: NOTES:
60 840
960
60
- HINGES TO BE FIXED AS PER JOINERY 60 740 60 - HINGES TO BE FIXED AS PER JOINERY P.O.Box 9440
CONTRACTOR RECOMMENDATION CONTRACTOR RECOMMENDATION
- ALL DOORS TO MEET ACOUSTICAL
860
- ALL DOORS TO MEET ACOUSTICAL Dubai
STANDARDS AS PER ACOUSTICAL STANDARDS AS PER ACOUSTICAL REPORT
REPORT PROVIDED BY SPECIALIST PROVIDED BY SPECIALIST United Arab Emirates
01 DOOR PLAN
- IF APPLIED IN WET AREA, DOOR TO BE
DONE ACCORDING TO WET AREA 01 DOOR PLAN - IF APPLIED IN WET AREA, DOOR TO BE DONE
ACCORDING TO WET AREA CONDITIONS AS PER 01 DOOR PLAN
CONDITIONS AS PER JOINERY PL Scale: 1:20 @ A0 JOINERY CONTRACTOR RECOMMENDATION PL Scale: 1:20 @ A0
PL Scale: 1:20 @ A0
CONTRACTOR RECOMMENDATION
CONSULTANT:

DUBAI - BEIRUT - CAIRO

SUB-CONSULTANT:

DRAWING TITLE:
NOTE:

FOR SELECTED IRONMONGERY REFER TO IRONMONGERY SPECIFICATION:


I64-02-IRON
FOR SELECTED DOOR FINISHES REFER TO FINISHES SPECIFICATION:
I64-01-SFIN
D14114-0100D MBR IFC I 4
PROJECT NO. BLDG TYP PHASE TRADE SHEET NUMBER REV

Anda mungkin juga menyukai