1 Product series
- Type & dimension
- Ratings
- Voltage
2 Options
3 Control
4 Highlights
5 Contact
2
ABB industrial drives, ACS850, drive modules, 1 to 600 Hp
Brake Options.................................................................9
Other Options................................................................11
Standard I/O..................................................................14
2
EMC filters.....................................................................15
Programming.................................................................16
Software features..........................................................17
3
PC tools........................................................................18
Remote monitoring and diagnostic tools........................19
3
ABB industrial drives
ACS850 - 04 - XX - 5 + XX
ABB industrial drives are highly flexible AC drives, designed ACS850-04 modules are UL listed in compliance with
for industrial applications, specifically for those in process UL508C-2003. They offer a wide range of internal options
industries such as the pulp & paper, metals, mining, cement, such as extended I/O and high speed communications. In
power, chemical, and oil & addition to these, a wide selection of external accessories is
gas industries. also available.
The drives can be configured to meet the precise needs of Because the modules are specifically designed for cabinet
these industries, and hence order-based configuration is an assembly, they can be mounted side-by-side. Cabinet
integral part of the offering. Covering a wide power and assembly documentation is included. The documentation
voltage range and with a vast array of standard and optional gives examples of different cabinet configurations,
features, the drives are readily programmable, making their examples of drawings and hints on the selection of auxiliary
adaptation to different applications easy. equipment. The flexibility and programmability of the
modules makes them an ideal choice for many applications in
Robust design a variety of industries.
The current ratings of ABB industrial drives are designed for Type code
applications that have a high overload requirement.
The type code is a unique reference number that clearly
At the heart of the drive is the motor control platform, identifies the drive by construction, power, voltage rating
Direct Torque Control (DTC) that provides accurate static and selected options. Using the type code you can specify
and dynamic speed and torque control, high starting torque your drives from the wide range of available selections.
and long motor cables. Customer-specific options are added to the type code using
the corresponding + code.
Furthermore, built-in drive options make the drive installation
fast and easy. Safe Torque Off
The drive is designed for a long working life and as such, The Safe Torque Off (STO) function disables the control
parts like fans and capacitors have been selected to maximize voltage of the power semiconductors in the drive output
their lifetime. This, together with the extensive protection stage, thus preventing the inverter from generating the
features and design details, such as coated circuit boards, voltage required to rotate the motor.
results in excellent reliability for the demanding industrial
market. With this function, the power supply does not need to be
turned off while doing cleaning or maintenance on the non-
Drive modules electrical parts of the machinery.
Drive modules are designed to be built into a customer’s The function meets the requirements of these safety
own cabinet. The ACS850-04 units are complete single drive standards:
modules that are optimized for this purpose, using minimal Safety Integrity Level 3 (SIL 3) according to IEC 61508
cabinet space while ensuring cabinet assembly is as easy as Safety Category 3 acc. to EN 954-1
possible.
4 1 Product series
Drive modules main features
Product series 1 5
Drive modules main features
6 1 Product series
Technical specifications
Product series 1 7
Types, ratings and dimensions
8 1 Product series
Brake options
The ACS850 has built in brake choppers for all types. There- Brake resistors are separately available for all ACS850 drives.
fore, no additional space or installation time is needed. The Resistors other than the standard resistors may be used pro-
brake chopper is part of the standard delivery for the frame viding the specified resistance value is not decreased, and the
sizes A-D. For the other frames a brake chopper is a select- heat dissipation capacity of the resistor is sufficient for the
able option. drive application.
Braking control is integrated into the ACS850 through frame For ACS850 units, no separate fuses in the brake circuit are
G. It controls the braking, supervises the system status and required if the following conditions are met:
detects failures such as brake resistor and resistor cable short n The ACS850 mains cable is protected with fuses
circuits, chopper short circuit, and calculated resistor overtem- n No mains cable/fuse overrating takes place
perature.
Dynamic Braking Table - 380-480V applications, stopping duty only
Duty Cycle = 3sec on / 27sec off Duty Cycle = 10sec on / 50sec off
Drive P/N HP
Resistor Resistor
ACS850-04- ND Ohms Watts Dimensions Ohms Watts Dimensions
Part No. Part No.
06A0-5 3 P14494-61 120 300 12Wx5Dx5H P14494-61 120 300 12Wx5Dx5H
08A0-5 5 P14494-61 120 300 12Wx5Dx5H ABB-48431-110 120 600 12Wx7Dx5H
10A0-5 5 ABB-48431-050 80 400 12Wx5Dx5H ABB-48431-052 80 800 12Wx7Dx5H
014A-5 7.5 ABB-41152 45 600 12Wx7Dx5H P14494-25 45 800 12Wx7Dx5H
018A-5 10 ABB-41152 45 600 12Wx7Dx5H P14494-26 45 1260 12Wx10Dx5H
025A-5 15 ABB-48431-002 22 819 12Wx7Dx5H ABB-48431-004 22 1408 12Wx13Dx5H
030A-5 20 ABB-41154 22 900 12Wx10Dx5H ABB-48431-005 22 1862 12Wx16Dx5H
035A-5 20 ABB-48431-003 22 1140 12Wx10Dx5H ABB-44472 22 1904 12Wx16Dx5H
044A-5 30 ABB-48431-030 13 1433 12Wx13Dx5H ABB-48431-033 13 3328 19Wx10Dx5H
050A-5 30 ABB-48431-030 13 1433 12Wx13Dx5H ABB-48431-033 13 3328 19Wx10Dx5H
061A-5 40 ABB-48431-031 13 1872 12Wx16Dx5H ABB-48431-033 13 3328 19Wx10Dx5H
078A-5 50 ABB-48431-033 13 3328 19Wx10Dx5H ABB-44495 13 4153 26.5Wx10Dx5H
094A-5 60 ABB-48431-033 13 3328 19Wx10Dx5H ABB-48431-036 13 6292 26.5Wx13Dx5H
103A-5 75 ABB-41170 8 4600 26.5Wx10Dx5H ABB-48431-120 8 6272 26.5Wx16Dx5H
144A-5 100 ABB-41161 6 4600 26.5Wx10Dx5H ABB-44499 6.1 9444 28Wx10Dx10H
166A-5 125 ABB-48431-183 4.3 6209 26.5Wx13Dx5H ABB-48431-184 4.3 10750 28Wx10Dx10H
202A-5 150 ABB-44479 4.26 9872 26.5Wx16Dx5H ABB-44480 4.26 11696 28Wx10Dx10H
225A-5 150 ABB-44479 4.26 9872 26.5Wx16Dx5H ABB-44480 4.26 11696 28Wx10Dx10H
260A-5 200 ABB-44479 4.26 9872 26.5Wx16Dx5H ABB-48431-185 4.3 17067 28Wx13Dx10H
Duty Cycle = 30sec on / 180sec off Duty Cycle = 60sec on / 180sec off
Drive P/N HP
Resistor Resistor
ACS850-04- ND Ohms Watts Dimensions Ohms Watts Dimensions
Part No. Part No.
06A0-5 3 ABB-48431-110 120 600 12Wx7Dx5H P14494-17 150 900 12Wx10Dx5H
08A0-5 5 ABB-48431-110 120 600 12Wx7Dx5H P14494-18 150 1200 12Wx13Dx5H
10A0-5 5 ABB-48431-052 80 800 12Wx7Dx5H ABB-48431-053 80 1600 12Wx13Dx5H
014A-5 8 P14494-26 45 1260 12Wx10Dx5H P14494-27 45 1920 12Wx16Dx5H
018A-5 10 P14494-26 45 1260 12Wx10Dx5H P14494-28 45 2450 19Wx13Dx5H
025A-5 15 ABB-48431-005 22 1862 12Wx16Dx5H ABB-48431-008 22 3168 19Wx13Dx5H
030A-5 20 ABB-48431-007 22 2426 19Wx10Dx5H ABB-48431-009 22 5632 26.5Wx10Dx5H
035A-5 23 ABB-44515 22 2910 19Wx13Dx5H ABB-48431-009 22 5632 26.5Wx10Dx5H
044A-5 30 ABB-44474 13 3558 19Wx10Dx5H ABB-48431-036 13 6292 26.5Wx13Dx5H
050A-5 30 ABB-44474 13 3558 19Wx10Dx5H ABB-48431-036 13 6292 26.5Wx13Dx5H
061A-5 40 ABB-44517 13.3 5093 26.5Wx13Dx5H ABB-48431-037 13 8125 26.5Wx16Dx5H
078A-5 50 ABB-48431-036 13 6292 26.5Wx13Dx5H ABB-48431-038 13 11700 28Wx13Dx10H
094A-5 60 ABB-48431-037 13 8125 26.5Wx16Dx5H ABB-48431-038 13 11700 28Wx13Dx10H
103A-5 75 ABB-48431-122 8 11552 28Wx10Dx10H ABB-48431-123 8 15488 28Wx16Dx10H
144A-5 100 ABB-44500 6.44 10892 28Wx10Dx10H ABB-44544 6.39 21955 28Wx16Dx10H
166A-5 125 ABB-48431-185 4.3 17067 28Wx13Dx10H ABB-48431-187 4.3 27520 30Wx18Dx24H
202A-5 150 ABB-48431-186 4.3 21070 28Wx16Dx10H ABB-48431-188 4.3 34830 30Wx18Dx24H
225A-5 150 ABB-48431-186 4.3 21070 28Wx16Dx10H ABB-48431-188 4.3 34830 30Wx18Dx24H
260A-5 200 ABB-48431-187 4.3 27520 30Wx18Dx24H ABB-48431-189 4.3 43000 30Wx18Dx24H
Options 2 9
Brake options
Duty Cycle = 3sec on / 27sec off Duty Cycle = 10sec on / 50sec off
Drive P/N HP
Resistor Resistor
ACS850-04- ND Ohms Watts Dimensions Ohms Watts Dimensions
Part No. Part No.
290A-5 200 ABB-48431-271 2.9 14210 28Wx10Dx10H ABB-48431-272 2.9 16313 28Wx10Dx10H
300 ABB-48431-330 2.2 14080 28Wx16Dx10H ABB-48431-332 2.2 26620 30Wx18Dx24H
430A-5 350 ABB-48431-331 2.2 17820 28Wx13Dx10H ABB-48431-333 2.2 31680 30Wx18Dx24H
400 ABB-48431-392 1.7 17000 28Wx13Dx10H ABB-48431-394 1.7 30983 30Wx18Dx32H
521A-5 450 ABB-48431-393 1.7 24480 30Wx18Dx16H ABB-44508 1.72 43916 30Wx18Dx32H
602A-5 500 ABB-48431-450 1.35 24604 30Wx18Dx16H ABB-48431-453 1.35 46204 30Wx18Dx32H
693A-5 550 ABB-48431-512 1 27225 30Wx18Dx24H ABB-48431-516 1 50625 30Wx18Dx24H
720A-5 600 ABB-48431-512 1 27225 30Wx18Dx24H ABB-48431-516 1 50625 30Wx18Dx24H
Duty Cycle = 30sec on / 180sec off Duty Cycle = 60sec on / 180sec off
Drive P/N HP
Resistor Resistor
ACS850-04- ND Ohms Watts Dimensions Ohms Watts Dimensions
Part No. Part No.
290A-5 200 ABB-48431-273 2.9 23490 28Wx16Dx10H ABB-48431-275 2.9 41760 30Wx18Dx32H
300 ABB-48431-334 2.2 40095 30Wx18Dx32H ABB-43503 2.27 68450 30Wx18Dx48H
430A-5 350 ABB-48431-334 2.2 40095 30Wx18Dx32H ABB-43503 2.27 68450 30Wx18Dx48H
400 ABB-44508 1.72 43916 30Wx18Dx32H ABB-43504 1.72 82280 30Wx18Dx40H
521A-5 450 ABB-48431-396 1.7 58183 30Wx18Dx32H ABB-43504 1.72 82280 30Wx18Dx40H
602A-5 500 ABB-48431-455 1.35 68344 30Wx18Dx32H ABB-44553 1.38 104527 30Wx18Dx72H
693A-5 550 ABB-48431-517 1 67600 30Wx18Dx40H ABB-48431-519 1 122500 (2) 30Wx18Dx40H
720A-5 600 ABB-48431-518 1 90000 30Wx18Dx48H ABB-48431-519 1 122500 (2) 30Wx18Dx40H
* Requires two resistor assemblies each rated as show and connected in series. (Order quantity 2)
10 2 Options
Options
The ACS850 drive modules have one of the most extensive The ACS850 drive modules have an embedded Modbus
offering of standard Inputs and Outputs (I/O) in the market. link as standard. This RS-485 link is galvanically isolated for
In addition, optional I/O extension modules are available, trouble-free operation and can be alternatively configured as
providing additional connection possibilities. Options include a high speed drive-to-drive link for master-follower operation.
analog and digital extension modules and pulse encoder
interface modules which are mounted in the slots on the Other fieldbus protocols are also supported, enabling
ACS850 control board. The control board has two slots connectivity to major automation systems. This is achieved
available for I/O extension modules. Additionally, there is a using dedicated interface modules between the different
third slot available for communication buses. fieldbus systems and ABB drives.
Options 2 11
Options
12 2 Options
Options
Du/dt filtering suppresses inverter output voltage spikes and Motor type Nominal mains
voltage (UN)
Motor insulation requirement
rapid voltage changes that stress motor insulation. ABB M2 and UN ≤ 500 V Standard insulation system.
M3 motors
Additionally, du/dt filtering reduces capacitive leakage ABB form- 380 V < UN ≤ 500 V Standard insulation system.
wound HXR
currents and high frequency emission of the motor cable and AM motors
as well as high frequency losses and bearing currents in the ABB random- 380 V < UN ≤ 500 V Check motor insulation system with
wound HXR the motor manufacturer.
motor. and AM motors
Non-ABB UN ≤ 420 V If the insulation system withstands
The need for du/dt filtering depends on the motor age and Random- ÛLL=1600 V and Δt=0.2 μs, du/dt
wound and filtering is not required. With du/dt
insulation. For information on the construction of the motor form-wound filtering the insulation system must
insulation, consult the motor manufacturer. If the motor does withstand ÛLL=1300 V.
du/dt filter type (3 filters included in kits marked *) du/dt filter Height Width Depth Weight
Unprotected (IP00) in in in lb
NOCH0016-60 7.7 5.5 4.5 5.28
* NOCH0120-60
* NOCH0260-60
NOCH0016-60
NOCH0030-60
NOCH0070-60
FOCH0260-70
FOCH0320-50
FOCH0610-70
Options 2 13
Standard I/O
Control unit
XPOW
External power input +24VI 1
24 V DC, 1.6 A GND 2
Analogue and XRO1, XRO2, XRO3
digital I/O Relay output RO1 [Ready] NO 1
extension 250 V AC / 30 V DC COM 2
2A NC 3
Relay output RO2 NO 4
250 V AC / 30 V DC COM 5
2A NC 6
Relay output RO3 NO 7
250 V AC / 30 V DC COM 8
2A NC 9
XD24
+24 V DC* +24VD 1
Digital input ground DIGND 2
+24 V DC* +24VD 3
Digital input/output ground DIOGND 4
Ground selection jumper
Feedback XDI
interface Digital input DI1 [Stop/Start] DI1 1
Digital input DI2 DI2 2
Digital input DI3 [Reset] DI3 3
Digital input DI4 DI4 4
Digital input DI5 DI5 5
Digital input DI6 or thermistor input DI6 6
Start interlock (0 = Stop) DIIL A
XDIO
Digital input/output DIO1 [Output: Ready] DIO1 1
Digital input/output DIO2 [Output: Running] DIO2 2
XAI
Reference voltage (+) +VREF 1
Reference voltage (–) -VREF 2
Ground AGND 3
Analog input AI1 (Current or voltage, selectable by jumper AI1) AI1+ 4
[Speed reference 1] AI1- 5
AI2+ 6
Analog input AI2 (Current or voltage, selectable by jumper AI2)
AI2- 7
AI1 current/voltage selection jumper AI1
AI2 current/voltage selection jumper AI2
XAO
AO1+ 1
Analog output AO1 [Current %]
Communication AO1- 2
AO2+ 3
interface Analog output AO2 [Speed %]
AO2- 4
XD2D
Drive-to-drive link termination jumper T
B 1
Drive-to-drive link. A 2
BGND 3
XSTO
OUT1 1
Safe Torque-Off. Both circuits must be closed for OUT2 2
the drive to start.
IN1 3
IN2 4
Control panel connection
Memory unit connection
Standard I/O
connections
■■ Control voltage supply: external supply (24V DC) input ■■ Safe Torque-Off (STO): designed for Safety Integrity
for the control unit Level 3 (SIL 3) according to IEC 61508 and Safety Cat-
■■ Digital I/O: 6xDI, 2xDI/O (can be used also for pulse egory 4 acc. to EN 954-1
train inputs or outputs, max 32 kHz), 3xRO ■■ Control panel connection: PC tools and control
■■ Analog I/O: 2xAI (mA or V), 2xAO panel connection (RJ45). Can be used also as a Modbus
■■ Thermistor input: motor thermistor (PTC, KTY) link for monitoring
■■ Start interlock: drive interlock input ■■ Memory unit connection: complete drive
■■ Drive-to-drive link: galvanically isolated, can also configuration and settings are stored in the
be used for ModBus removable memory unit
14 2 Options
EMC filters
1st environment vs 2nd environment the specific EMC requirements stated for drives (tested with
motor and cable) within the EU.
1st environment (category C1 & C2)
1st environment includes domestic premises. It also includes EMC standards such as EN 55011, or EN 61000-6-3/4, are
establishments directly connected without intermediate applicable to industrial and domestic equipments and systems
transformer to a low-voltage power supply network which including drive component inside. Drive units complying with
supplies buildings used for domestic purposes. requirements of EN 61800-3 are compliant with comparable
categories in EN 55011 and EN 61000-6-3/4, but not
2nd environment (category C3 & C4) necessarily vice versa. EN 55011 and EN 61000-6-3/4 do not
2nd environment includes all establishments other than those specify cable length nor require a motor to be connected as
directly connected to a low-voltage power supply network a load. The emission limits are comparable according to the
which supplies buildings used for domestic purposes. following table, EMC standards.
EMC standards
EN61800-3 (2004) product standard EN 55011, product family standard EN61000-6-4, generic emission EN61000-6-3, generic emission
for industrial, scientific and medical standard for industrial environments standard for residential, commercial
(ISM) equipment and light-industrial environment
Category C1 Group 1 Not applicable Applicable
(1st environment) Class B
Category C2 Group 1 Applicable Not applicable
(1st environment) Class A
Category C3 Group 2 Not applicable Not applicable
(2nd environment) Class A
Category C4 Not applicable Not applicable Not applicable
(2nd environment)
Options 2 15
Programming
The standard ACS850 program offers flexibility and Removable memory block
extensive parameter settings. It consists of a simple, ready-
made program that can easily be modified to meet specific A removable memory block provides easy maintenance by
application needs. Commissioning is also simplified with the storing the complete firmware, including all user settings
help of the start-up assistant that come standard with every and motor data. Thus, if the power unit or control unit is
drive. replaced, the drive can be re-commissioned without any
reprogramming, just move the memory block.
Pre-programmed protection functions
■■ Stores the drive firmware and parameter settings
A wide range of features provides protection for the drive, ■■ Fast and easy recommissioning
motor and the process. ■■ Enables firmware and parameter configuration at work-
shop instead of doing it on-site
■■ Ambient temperature
■■ DC overvoltage
■■ DC undervoltage
■■ Drive temperature
■■ Input phase loss
■■ Overcurrent
■■ Power limits
■■ Short circuit
16 3 Control
Software features
ABB industrial drive modules have many features to enhance Diagnostic assistant
their reliability and durability as well as the ease of use. Among
those, several macros for parameter settings and several Each ACS850-04 drive module is equipped with a diagnostic
advanced functions such as short and long parameter menus, assistant that helps in locating the cause of any disturbance to
I/O mapping and changed parameters list, makes the drive the drive and even suggests possible remedies. This reduces
simple to use. process downtime
by making repair or adjustments quicker and easier.
All these functions can be accessed either via the user-friendly
control panel or DriveStudio PC tool. Energy saving calculator
Several macros which have pre-set, application-specific ■■ An energy efficiency optimizer that adjusts the motor flux
parameter settings are available as standard in each drive. in such a way that the total efficiency
These pre-programmed parameter settings enable fast and is maximized
easy commissioning by adjusting all the relevant parameters ■■ A counter that monitors used and saved energy
in just a couple of clicks. by the motor and displays them in kWh, currency
($ or €) or volume of CO2 emission
Start-up assistant ■■ A load analyzer showing the load profile of the drive
The intelligent and intuitive start-up assistant allows first- Short/long menus
time users to quickly get up-to-speed and customize the
drive according to their needs. This is complemented by a The user interface can be configured so that it displays only
built-in help function to make parameter-by-parameter setting the most common parameters. This short menu allows users
easy. This way the drive can be quickly commissioned, even to quickly access the parameters they need without having to
without manuals. go through all the drive’s parameters.
Control 3 17
PC tools
DriveStudio DriveSize
User-friendly PC tool for quick drive startup, drive tuning and DriveSize is a PC program for helping the user select the
advanced programming tasks. optimal motor, frequency converter and transformer,
especially in the case where a straightforward selection
Start-up and maintenance tools: from a catalogue is not possible. Additionally it can be used
■■ Fast parameter navigation to compute currents, network harmonics and to create
■■ Parameter setting documents about the dimensioning based on actual load.
■■ Data logging and online drive signal monitoring of multi-
ple signal channels for drive tuning DriveSize contains the current versions of the ABB motor
■■ Back-up and restore tool for drive parameter and and AC drive catalogues.
DriveSPC program cloning
■■ Case sensitive help with detailed descriptions of drive The default values make DriveSize simple to use, and the
parameters, events and functions user is provided with ample options for drive selection. The
■■ Overview of the drive performance and status shortcut keys make drive selection
easy while giving the optimal dimensioning result.
DriveSPC A manual selection mode is also supported.
18 3 Control
Remote monitoring and diagnostic tools
With drives increasingly being installed in remote locations, SREA-01 also has an internal Modbus TCP gateway,
operational data needs to be acquired from the process for providing a standard interface that can be used by SCADA
sending to a central location for process monitoring and (Supervisory Control And Data Acquisition) applications to
further analysis. Furthermore, with no qualified service display drive information in real-time.
people on site it is vital to be able to monitor the drive
remotely. Receive alarms and access the drive
remotely
ABB’s SREA-01 Ethernet adapter performs all these remote
access tasks. Designed as an optional remote interface The SREA-01 unit can be used to monitor the drive for
module for the drives, the SREA-01 can send process data, abnormal situations, such as too high process temperatures,
data logs and event messages independently, without a PLC
or a dedicated on-site computer, and has an internal web
server for configuration and drive access.
Control 3 19
Summary of features and options
20 4 Highlights
Contact and web information
www.abb.us/drives
ABB’s worldwide presence is built on strong local companies For further details about all our low voltage AC drives and
working together with the channel partner network. By services please contact your nearest ABB office
combining the experience and know-how gained in local and or ABB drives channel partner or visit the websites
global markets, we ensure that our customers in all industries www.abb.com/drives and www.abb.com/drivespartners.
can gain the full benefit from our products.
Albania (Tirana) Croatia (Zagreb) Israel (Haifa) Oman (Muscat) Sri Lanka (Colombo)
Tel: +355 42 241 492 Tel: +385 1 600 8550 Tel: +972 4 850 2111 Tel: +968 2456 7410 Tel: +94 11 2399304/6
Fax: +355 42 234 368 Fax: +385 1 619 5111 Fax: +972 4 850 2112 Fax: +968 2456 7406 Fax: +94 11 2399303
Algeria Czech Republic (Prague) Italy (Milan) Pakistan (Lahore) Sweden (Västerås)
Tel: +213 21 553 860 Tel: +420 234 322 327 Tel: +39 02 2414 3085 Tel: +92 42 6315 882-85 Tel: +46 (0)21 32 5000
Fax: +213 21 552 330 e-mail: motors&drives@cz.abb.com Fax: +39 02 2414 3979 Fax: +92 42 6368 565 Fax: +46 (0)21 14 8671
Argentina (Valentin Alsina) Denmark (Skovlunde) Ivory Coast (Abidjan) Panama (Panama City) Switzerland (Zürich)
Tel: +54 11 4229 5500 Tel: +45 44 504 345 Tel: +225 21 21 7575 Tel: +507 209 5400, 2095408 Tel: +41 (0)58 586 0000
Fax: +54 11 4229 5784 Fax: +45 44 504 365 Fax: +225 21 35 0414 Fax: +507 209 5401 Fax: +41 (0)58 586 0603
Australia (Victoria - Notting Hill) Dominican Republic (Santo Japan (Tokyo) Peru (Lima) Syrian Arab Republic
Tel: +1800 222 435 Domingo) Tel: +81(0)3 5784 6010 Tel: +51 1 415 5100 Tel: +963 11 212 7018 / 9551
Tel: +61 3 8544 0000 Tel: +809 562 9010 Fax: +81(0)3 5784 6275 Fax: +51 1 561 2902 Fax: +963 11 212 8614
e-mail: drives@au.abb.com Fax: +809 562 9011
Jordan (Amman) The Philippines (Metro Manila) Taiwan (Taipei)
Austria (Vienna) Ecuador (Quito) Tel: +962 6 562 0181 Tel: +63 2 821 7777 Tel: +886 2 2577 6090
Tel: +43 1 60109 0 Tel: +593 2 2500 645 Fax: +962 6 5621369 Fax: +63 2 823 0309, 824 4637 Fax: +886 2 2577 9467, 2577
Fax: +43 1 60109 8312 Fax: +593 2 2500 650 9434
Kazakhstan (Almaty) Poland (Lodz)
Azerbaijan (Baku) Egypt (Cairo) Tel: +7 727 2583838 Tel: +48 42 299 3000 Tanzania (Dar es Salaam)
Tel: +994 12 404 5200 Tel: +202 2 6251630 Fax: +7 727 2583839 Fax: +48 42 299 3340 Tel: +255 51 2136750, 2136751,
Fax: +994 12 404 5202 drives@eg.abb.com 2136752
Kenya (Nairobi) Portugal (Oeiras) Fax: +255 51 2136749
Bahrain (Manama) El Salvador (San Salvador) Tel: +254 20 828811/13 to 20 Tel: +351 21 425 6000
Tel: +973 725 377 Tel: +503 2264 5471 Fax: +254 20 828812/21 Fax: +351 21 425 6390, 425 6354 Thailand (Bangkok)
Fax: +973 725 332 Fax: +503 2264 2497 Tel: +66 (0)2665 1000
Kuwait (Kuwait city) Qatar (Doha) Fax: +66 (0)2665 1042
Bangladesh (Dhaka) Estonia (Tallinn) Tel: +965 2428626 ext. 106 Tel: +974 4253888
Tel: +88 02 8856468 Tel: +372 6801 800 Fax: +965 2403139 Fax: +974 4312630 Tunisia (Tunis)
Fax: +88 02 8850906 e-mail: info@ee.abb.com Tel: +216 71 860 366
Latvia (Riga) Romania (Bucharest) Fax: +216 71 860 255
Belarus (Minsk) Ethiopia (Addis Abeba) Tel: +371 7 063 600 Tel: +40 21 310 4377
Tel: +375 228 12 40, 228 12 42 Tel: +251 1 669506, 669507 Fax: +371 7 063 601 Fax: +40 21 310 4383 Turkey (Istanbul)
Fax: +375 228 12 43 Fax: +251 1 669511 Tel: +90 216 528 2200
Lithuania (Vilnius) Russia (Moscow) Fax: +90 216 365 2944
Belgium (Zaventem) Finland (Helsinki) Tel: +370 5 273 8300 Tel: +7 495 960 22 00
Tel: +32 2 718 6320 Tel: +358 10 22 11 Fax: +370 5 273 8333 Fax: +7 495 960 22 20 Uganda (Nakasero, Kampala)
Fax: +32 2 718 6664 Tel: +358 10 222 1999 Tel: +256 41 348 800
Fax: +358 10 222 2913 Luxembourg (Leudelange) Saudi-Arabia (Al Khobar) Fax: +256 41 348 799
Bolivia (La Paz) Tel: +352 493 116 Tel: +966 (0)3 882 9394, ext. 240,
Tel: +591 2 278 8181 France (Montluel) Fax: +352 492 859 254, 247 Ukraine (Kiev)
Fax: +591 2 278 8184 Tel: +33 (0)4 37 40 40 00 Fax: +966 (0)3 882 4603 Tel: +380 44 495 22 11
Fax: +33 (0)4 37 40 40 72 Macedonia (Skopje) Fax: +380 44 495 22 10
Bosnia Herzegovina (Tuzla) Tel: +389 23 118 010 Senegal (Dakar)
Tel: +387 35 246 020 Germany (Ladenburg) Fax: +389 23 118 774 Tel: +221 832 1242, 832 3466 The United Arab Emirates (Dubai)
Fax: +387 35 255 098 Tel: +01805 222 580 (Service) Fax: +221 832 2057, 832 1239 Tel: +971 4 3147500, 3401777
Tel: +49 (0)6203 717 717 Malaysia (Kuala Lumpur) Fax: +971 4 3401771, 3401539
Brazil (Osasco) Fax: +49 (0)6203 717 600 Tel: +603 5628 4888 Serbia (Belgrade)
Tel: 0800 014 9111 Fax: +603 5635 8200 Tel: +381 11 3094 320, 3094 300 United Kingdom (Daresbury,
Tel: +55 11 3688 9282 Greece (Athens) Fax: +381 11 3094 343 Warrington)
Fax: +55 11 3688 9421 Tel: +30 210 289 1 651 Mauritius (Port-Louis) Tel: +44 1925 741 111
Fax: +30 210 289 1 792 Tel: +230 208 7644, 211 8624 Singapore (Singapore) Fax: +44 1925 741 693
Bulgaria (Sofia) Fax: +230 211 4077 Tel: +65 6776 5711
Tel: +359 2 807 5500 Guatemala (Guatemala City) Fax: +65 6778 0222 Uruguay (Montevideo)
Fax: +359 2 807 5599 Tel: +502 2 363 3814 Mexico (Mexico City) Tel: +598 2 707 7300
Fax: +502 2 363 3624 Tel: +52 (55) 5328 1400 ext. 3008 Slovakia (Banska Bystrica) Tel: +598 2 707 7466
Canada (Montreal) Fax: +52 (55) 5328 7467 Tel: +421 48 410 2324
Tel: +1 514 420 3100 Hungary (Budapest) Fax: +421 48 410 2325 USA (New Berlin)
Fax: +1 514 420 3138 Tel: +36 1 443 2224 Morocco (Casablanca) Tel: +1 800 752 0696
Fax: +36 1 443 2144 Tel: +212 52 234 5540 Slovenia (Ljubljana) Tel: +1 262 785 3200
Chile (Santiago) Fax: +212 52 234 2099 Tel: +386 1 2445 440 Fax: +1 262 785 0397
Tel: +56 2 471 4391 India (Bangalore) Fax: +386 1 2445 490
Fax: +56 2 471 4399 Tel: +91 80 2294 9585 The Netherlands (Rotterdam) Venezuela (Caracas)
Fax: +91 80 2294 9389 Tel: +31 (0)10 407 8886 South Africa (Johannesburg) Tel: +58 212 2031949
China (Beijing) e-mail: freqconv@nl.abb.com Tel: +27 11 617 2000 Fax: +58 212 237 6270
Tel: +86 10 5821 7788 Indonesia (Jakarta) Fax: +27 11 908 2061
Fax: +86 10 5821 7618 Tel: +62 21 2551 5555 New Zealand (Auckland) Vietnam (Hochiminh)
e-mail: automation@id.abb.com Tel: +64 9 356 2160 South Korea (Seoul) Tel: +84 8 8237 972
Colombia (Bogotá) Fax: +64 9 357 0019 Tel: +82 2 528 2794 Fax: +84 8 8237 970
Tel: +57 1 417 8000 Iran (Tehran) Fax: +82 2 528 2338
Fax: +57 1 413 4086 Tel: +98 21 2222 5120 Nigeria (Ikeja, Lagos) Zimbabwe (Harare)
Fax: +98 21 2222 5157 Tel: +234 1 4937 347 Spain (Barcelona) Tel: +263 4 369 070
Costa Rica (San Jose) Fax: +234 1 4937 329 Tel: +34 (9)3 728 8500 Fax: +263 4 369 084
Tel: +506 288 5484 Ireland (Dublin) Fax: +34 (9)3 728 7659
Fax: +506 288 5482 Tel: +353 1 405 7300 Norway (Oslo)
Fax: +353 1 405 7307 Tel: +47 03500
motor@no.abb.com
Contact 5 21
Notes
22
Notes
23
Contact us
ABB09_00220/2009
ABB Inc.
Low Voltage Drives
16250 W. Glendale Drive
© Copyright 2010 ABB. All rights reserved.
ABB Inc.
Low Voltage Drives- Canada
2117, 32nd Avenue
Lachine, QC H8T 3J1
Phone: (800) 215-3066
Fax: (514) 420- 3137
Web: www.abb.com