Anda di halaman 1dari 1

CORNER POST TO BE CRANKED

TO SUIT LINE OF BARBED WIRE


INTERMIDIATE POST
DETAIL "X" SEE DETAIL "X"

BLOCK MASONRY BLOCK MASONRY


1 1
Ø10@150c/c

Ø10@150c/c

Ø10@150c/c

Ø10@150c/c
1825

2-Ø13 2-Ø13 3
3650

Ø10@150c/c Ø10@150c/c Ø10@150c/c Ø10@150c/c

2-Ø13 2-Ø13
BRACE BEAM 3
150x300
1825

8-Ø13 8-Ø13 8-Ø13 8-Ø13

BLOCK MASONRY BLOCK MASONRY

Y.L
LAP
500

2-Ø13 2-Ø13 2
150

R.L
450

Ø10@150c/c Ø10@150c/c Ø10@150c/c Ø10@150c/c


REFERENCE DRAWINGS
1000
150

2-Ø13 2-Ø13 Description Drawing Number


PLINTH BEAM 2
200x450
100 300

P.C.C 1:4:8 P.C.C 1:4:8 P.C.C 1:4:8


Ø13@200c/c Ø13@200c/c Ø13@200c/c
Ø13@200c/c Ø13@200c/c Ø13@200c/c
100 1500 100 100 1500 100 100 1800 100

SECTION A-A

5000 5000 320


FOR APPROVAL

Pakistan Defence Officers


Housing Authority Karachi
1500

300x300 R.C.C 20mm THICK EXPANSION Pak Elektron Ltd.


150mm TH. BLOCK MASONRY COLUMN PLINTH BEAM JOINT AFTER 8 PANELS 14-KM, FEROZEPUR ROAD-LAHORE, PAKISTAN
200x450 B
A A
Smart Engineering Solution
3rd Floor, Uni Tower, 30-A, Lawrence Road,
Lahore, Pakistan
1500 3500 1500 3410 2000

B
TYPICAL FOOTING PLAN SIDE "A" , "B" & "C"
BOUNDARY WALL PLAN & SECTIONS

16P015P-EALD