Anda di halaman 1dari 33

1 II Green Rating for Integrated Habitat Assessment II

Input energy - kW

Light output - lumen

Light quantity - lux

2 II Green Rating for Integrated Habitat Assessment II


Lighting levels in each space
of proposed indoor lighting
design meet the required
visual comfort as
recommended in table 4,
Part 8, Building Services,
section 1: Lighting &
Ventilation of NBC-2005

3 II Green Rating for Integrated Habitat Assessment II


NBC-2005 recommended lighting levels

4 II Green Rating for Integrated Habitat Assessment II


Room
Dimensions

Fixture/lamp
type Lighting levels

Fixture layout

Lighting design efficiency ?

5 II Green Rating for Integrated Habitat Assessment II


Design lighting level

Room Maintenance Factor

Surface Reflectance

Furniture layout/Work plane height

Lighting equipment details

6 II Green Rating for Integrated Habitat Assessment II


NBC-2005 Part 8, Building Services, Section 1: Lighting & Ventilation
Table 4 : Recommended lighting levels

For working interiors the middle


value of each range represents the
recommended illuminance

In case precise height and


location of the task is not
specified, the recommended
working plane is horizontal and at
a height of 850 mm

7 II Green Rating for Integrated Habitat Assessment II


Effective lighting design
!

Non AC spaces:
0.7-0.75
AC spaces: 0.8-
0.95

8 II Green Rating for Integrated Habitat Assessment II


" Effective
# lighting
# design

Roof:0.7
Wall:0.5
Floor:0.2

9 II Green Rating for Integrated Habitat Assessment II


! $
T-12
20 W : 1015 lm
40 W : 2450 lm

T-8 (Mono-phosphor)
18 W : 1015 lm
36 W : 2450 lm
58 W : 4000 lm

T-8 (Tri-phosphor)
18 W : 1300 lm
36 W : 3250 lm

T-5
14 W : 1350 lm
28 W : 2900 lm

10 II Green Rating for Integrated Habitat Assessment II


$ # $% ! &

Direct Fit
5W : 235 lm
9W : 450 lm
11 W : 600 lm
15 W : 860 lm
20 W : 1150 lm
25 W : 1360 lm

Pin type
9W : 600 lm
11 W : 900 lm
13 W : 900 lm
18 W : 1200 lm
26 W : 1800 lm
36 W : 2900 lm

11 II Green Rating for Integrated Habitat Assessment II


Fluorescent lamps
Electromagnetic : 10 -12 W
Low loss electromagnetic : 4.5 W
Electronic choke : 1-3 W

CFL
Electromagnetic : 4.5 – 5.5 W
Electronic : 1 – 2.5 W

12 II Green Rating for Integrated Habitat Assessment II


Direct light to required place
Protect lamps
Reduce glare

13 II Green Rating for Integrated Habitat Assessment II


"

14 II Green Rating for Integrated Habitat Assessment II


15 II Green Rating for Integrated Habitat Assessment II
!

AC room 0.85

Data/
Project options/
Project Maintenance
Factor: 0.85

16 II Green Rating for Integrated Habitat Assessment II


Length 23.97 m Data/
Width 6.37 m Room/
Height 3.3 m
Dimensions/
Work plane 0.85 m

17 II Green Rating for Integrated Habitat Assessment II


" # #

Ceiling 0.7 Data/


Walls 0.5
Room/
Floor 0.2
Reflectances/

18 II Green Rating for Integrated Habitat Assessment II


Data/
Room/
Req. Illum. levels/
300

19 II Green Rating for Integrated Habitat Assessment II


Data/
Grids/
Add/
Coupling
Connected to: work plane

20 II Green Rating for Integrated Habitat Assessment II


' (

Data/
Project luminaires/
Add/
File/
Desktop/
Criterion 13/
TCS306_236 Normal
2*TLD

21 II Green Rating for Integrated Habitat Assessment II


Lighting Simulation
Data/
Arranged luminaires/
Add/
Room block/
No. of luminaires needed/
8/
Generate/
Ok/
Close/
Calculations/
Show results

22 II Green Rating for Integrated Habitat Assessment II


Simulation results

Report/
Print preview/
Next page/
Next page

23 II Green Rating for Integrated Habitat Assessment II


Summary of Result

Floor Room Room Luminaire No. of Calculated NBC-2005 Remarks


Level / Area Dimen used luminaires Average illuminance
sion Lighting Levels (lux)
(L*W) (lux)
First Office 23.97m TCS 306 8 124 300 Under
Floor X6.37 /236 illuminated
m

24 II Green Rating for Integrated Habitat Assessment II


Lighting Simulation
Data/
Arranged luminaires/
db click Room block/
No. of luminaires needed/
20/
Generate/
Ok/
Close/
Calculations/
Show results

25 II Green Rating for Integrated Habitat Assessment II


Simulation results

Report/
Print preview/
Next page/
Next page

26 II Green Rating for Integrated Habitat Assessment II


Result

Floor Room Room Luminaire No. of Calculated NBC-2005 Remarks


Level / Area Dimen used luminaires Average illuminance
sion Lighting Levels (lux)
(L*W) (lux)
First Office 23.97m TCS 306 20 300 300 Ok
Floor X6.37 /236
m

27 II Green Rating for Integrated Habitat Assessment II


) ' $

Lighting Power Density (LPD) :Total


connected load of a space/floor area of the
space

28 II Green Rating for Integrated Habitat Assessment II


*$ +

•Average lighting levels shall not be less than 500 lux


•LPD shall not be more than 11.8 W/m2
29 II Green Rating for Integrated Habitat Assessment II
#" ,

Indoor lighting design layouts with fixture/lamp &


control details
Illumination level analysis table
Manufacturers technical data sheets

30 II Green Rating for Integrated Habitat Assessment II


$$

If lighting level compliance is shown for all the indoor


spaces

• 2 Points

31 II Green Rating for Integrated Habitat Assessment II


)
% - #
#&

"

32 II Green Rating for Integrated Habitat Assessment II


)
"$ .

" #
!
!

% $

33 II Green Rating for Integrated Habitat Assessment II