16.05.

2012

Holcim Filipina
Pabrik La Union

Hubungi Corporate OH&S untuk detilnya

Terjadi kejadian hampir celaka...


Pada tanggal 3 Mei 2012 sekitar pukul 2 siang, terjadi insiden pada saat dilakukan test running auxiliary fan (533-
FN1). Sesaat sebelum insiden terdengar bunyi yang tidak biasa, fan dihentikan untuk dilakukan pemeriksaan. Pada
saat pemeriksaan ditemukan sebuah bilah impeller yang telah terpasang (dilas), seberat 1.5 kg terlepas dan
terlempar keluar melalui lubang stack. Bilah fan mendarat sejauh 30 m dari bangunan dari ketinggian 25 m.
Kejadian ini mengakibatkan casing fan rusak dan bilah impeller terlepas. Tidak ada yang terluka dalam insiden ini.

Titik keluar bilah Bilah impeller yang


impeller (bukaan terlepas, sekitar
stack) 1.5 kg

Sekitar
25 m

Titik dimana bilah


impeller jatuh
Sekitar 30 m

Inti Pembelajaran
Jika memungkinkan, pertimbangkan hal-hal berikut ini::

• Periksa manual pabrikan peralatan/fasilitas sebagai panduan pemeliharaan sebelum melakukan perbaikan
atau penggantian suku cadang.
• Jika tidak ada tenaga ahli atau peralatan untuk melakukan perbaikan atau mengganti bagian yang aus,
maka tenaga ahli dari pabrik pembuat mesti dipanggil untuk memastikan perbaikan dilakukan dengan
baik.
• Pastikan petugas pemeliharaan memiliki akses ke manual perawatan dari pabrik pembuat sebagai
panduan perbaikan dan/atau perawatan peralatan dan fasilitas pabrik.
• Pastikan proses dan praktek pemeriksaan kualitas hasil pekerjaan dilakukan dengan baik untuk pekerjaan
perbaikan atau penggantian bagian pada mesin dengan putaran cepat dan/atau alat bertekanan.

Periksa dan pastikan hal ini tidak terjadi di tempat anda!


Form No. SF1042
1 May 2012 Ver. 1.4
16.05.2012

Holcim Philippines
La Union Plant

Contact OH&S Corporate for more details

Near miss incident has happened…


On 3rd May, 2012 at approximately 2:00 pm (14:00hrs), an incident occurred during the test running of an
auxiliary fan (533-FN1). Immediately prior to the incident an unusual sound was heard, the fan was stopped for
inspection. Upon inspection it was found that a welded impeller blade, weighing 1.5 kg had detached and had
flown out from the exhaust stack. The fan blade had landed approximately 30m away from the building from a
height of 25m. This incident resulted in a damaged fan casing and detached impeller blade. No one was hurt by the
incident.

Key Learnings
If applicable, please consider the following aspects:
• Check the manufacturer manual of plant and equipment to guide maintenance requirements prior to
undertaking any repairs or replacement of parts.
• If the operation does not have the expertise or equipment to undertake repairs or replace worn out parts,
then suitable expertise shall be sought from the manufacturer / fabricator to ensure proper repairs are
performed.
• Ensure Maintenance personnel have access to the designer/manufacturer’s service manual to guide them
in undertaking servicing and/or repairs to plant and equipment.
• Ensure suitable processes and practices are established for authorizing and performing inspections on the
quality of work when repairs or replacements parts are installed on high speed rotating machinery and/or
pressurized equipment.

Please check and ensure this cannot happen in your workplace!


Form No. SF1042
1 May 2012 Ver. 1.4