CONVENTIONAL SOLUTIONS

SFP-2402/04 FIRE ALARM CONTROL PANELS

Initiating Device Circuits (IDCs)


2 IDCs on the SFP-2402; 4 IDCs on the SFP-2404 2151 Photo Detector
i3 Series
Smoke Detector

NBG-12 Series Manual Pull Stations


Notification Appliance Circuits (NACs)
1 NAC on the SFP-2402; 2 NACs on the SFP-2404

24 VDC non-resettable power (SFP-2404 only)


P2R Horn/Strobes
Alarm and Trouble Contacts
411/411UD

SFP-2402
The SFP-2402 is a conventional fire alarm
control panel with two alarm initiating zones.
• Two Class B Initiating Device Circuits (IDCs)
• One Class B Notification Appliance
RP-2001/02 DELUGE/PRE-ACTION
(NAC) with programmable strobe
synchronization
• 3.0 amps total system power
• Form-C Alarm and Trouble relays
• Optional Voice Evacuation with direct connect Initiating Device Circuits (IDCs)
6 IDCs on the RP-2001 and RP-2002
to FireVoice 25/50
• Resettable auxillary 24 VDC power
• UL 864 Ninth Edition listed Notification Appliance Circuits (NACs)
SFP-2404 4 NACs/Releasing Circuits on the RP-2001 and RP-2002
The SFP-2404 is a conventional fire alarm Up to 8 A
control panel with four alarm initiating zones.
• Four Class B Initiating Device Circuits (IDCs),
Class A option available ANN-BUS
• Two Class B Notification Appliance Circuits N-ANN-80 N-ANN-I/O N-A
(NACs) with programmable strobe
synchronization; Class A option available RP-2001
• 3.0 amps total system power, expandable
The RP-2001 is a six-zone fire alarm panel for single or dual hazard deluge and
to 6.0 amps
preaction applications. The RP-2001 is easily programmed with just a few menu
• Form-C Alarm, Trouble and Supervisory relays
selections using field selectable “application templates.” The RP-2001 offers fire
• Optional Voice Evacuation with direct connect
detection, signaling and protection for commercial, industrial and institutional
to FireVoice 25/50
buildings requiring water-based releasing.
• Optional local energy box or reverse
• Six Class B Initiating Device Circuits (IDCs); Class A optional with N-CAC-5X
polarity XMTR
converter module (2 required)
• Optional LED remote annunciator
• Four Class B Output Circuits programmable as Notification Appliance Circuits
• Optional zone relay module
(NACs), or releasing circuits; rated at 3.0 amps; Class A optional with N-CAC-5X
• Resettable and non-resettable auxillary
converter module (2 required)
24 VDC power
• Programmable waterflow discharge timer and two soak timers
• UL 864 Ninth Edition listed
• Cross-zone (double-interlock) capability
• Meets NFPA standards 13, 15 and 16
• Three Form-C programmable relays for Alarm, Trouble and Supervisory
• Up to eight ANN-BUS devices (such as LCD annunciators)
• 80 character LCD display
• 7.0 amps total system power
• UL 864 Ninth Edition listed
SFP-5UD/10UD FIRE ALARM CONTROL PANELS
WITH COMMUNICATORS

Initiating Device Circuits (IDCs)


5 IDCs on the SFP-5UD; 10 IDCs on the SFP-10UD
2151 Photo Detector i3 Series
Smoke Detector

NBG-12 Series Manual Pull Stations Notification Appliance Circuits (NACs)


4 NACs on the SFP-5UD and SFP-10UD

Up to 8 ANN-BUS devices
P2R Horn/Strobes

ANN-BUS
N-ANN-LED N-ANN-RLY N-ANN-S/PG N-ANN-I/O N-ANN-80

SFP-5UD
The SFP-5UD is a 5-zone fire alarm control
panel with a built-in digital alarm communicator
N AND RELEASING CONTROL PANELS transmitter (DACT) and remote site
upload/download capability.
• Five Class B Initiating Device Circuits (IDCs),
Class A optional with N-CAC-5X converter
module
• Four Class B NACs rated at 2.5 amps, Class A
optional with N-CAC-5X converter module
i3 Series 2151 Photo Detector • 3.0 amps total system power
Smoke Detector • Up to eight ANN-BUS devices (such as LCD
annunciators)
NBG-12 Series Manual Pull Stations • Serial or parallel printer interface
• 80-character LCD display
ANN-BUS devices
• Optional Voice Evacuation available
P2R Horn/Strobes
with direct connect to FireVoice 25/50
• Optional IP Communicator
• UL 864 Ninth Edition listed
ANN-S/PG N-ANN-RLY N-ANN-LED
SFP-10UD
RP-2002 The SFP-10UD is a 10-zone fire alarm control
panel with a built-in digital alarm communicator
The RP-2002 is a six-zone fire alarm control panel for single or dual hazard agent
transmitter (DACT) and remote site
releasing applications. The RP-2002 offers fire detection, signaling and protection
upload/download capability.
for facilities requiring agent-based releasing. Like the RP-2001, this panel can be pro-
• Ten Class B Initiating Device Circuits (IDCs),
grammed with an “application template” while remaining completely field-customizable.
Class A optional with N-CAC-5X converter
• Six Class B Initiating Device Circuits (IDCs); Class A optional with N-CAC-5X converter
module (2 required)
module (2 required)
• Four Class B NACs rated at 3.0 amps,
• Four Class B Output Circuits rated at 3.0 amps; programmable as Notification
Class A optional with N-CAC-5X converter
Appliance Circuits (NACs), or releasing circuits; Class A optional with N-CAC-5X
module (2 required)
converter module (2 required)
• 7.0 amps total system power
• Adjustable pre-discharge, discharge, and waterflow delay
• Up to eight ANN-BUS devices (such as LCD
• Meets NFPA standards 12, 12A, 12B, and 2001
annunciators)
• Disable/Enable control per input zone and output zone
• Serial or parallel printer interface
• Cross-zone (double-interlock) capability
• 80-character LCD display
• Three Form-C programmable relays for Alarm, Trouble and Supervisory
• Optional Voice Evacuation available
• Up to eight ANN-BUS devices (such as LCD annunciators)
with direct connect to FireVoice 25/50
• 80 character LCD display
• Optional IP Communicator
• 7.0 amps total system power
• UL 864 Ninth Edition listed
• UL 864 Ninth Edition listed
NOTIFIER WORLD HEADQUARTERS
12 Clintonville Road
Northford, CT 06472
United States of America
Tel: 203-484-7161
Fax: 203-484-7118
www.notifier.com

For information on regional office locations throughout the world, please visit www.notifier.com.

Fire Alarm Emergency


Control Panels Communication
Systems

Fire Alarm Advanced Fire &


Networks Smoke Detection

Fire, Security, Gas Detection


CCTV Integration

For over 60 years, NOTIFIER has been a leader in the fire alarm industry. Today, we are
the largest manufacturer of engineered fire alarm systems with over 400 distributors
worldwide, and regional support operations on every continent for the flexibility and
options your business needs.

NOTIFIER - Leaders in Life. Safety. Technology.

M-B-CONV 12/10