When installing the VC-FC module, NPIV must be enabled on the fabric switch that is
attached to the VCFC module uplinks before the server blade HBAs can log in to the
fabric. See the Fibre Channel switch firmware documentation for information on
whether it supports NPIV and for instructions on enabling this support.
Brocade switch
Most Brocade Fibre Channel switches running Fabric OS 5.1.0 or later will support
NPIV. All Brocade 4Gb and 8Gb-capable Fibre Channel switches are configured with
NPIV enabled by default.
When not enabled by default, use the portCfgNPIVPort command within the Brocade
switch command line interface to enable NPIV. For additional information on usage
of the portCfgNPIVPort command, see the Brocade switch firmware documentation.
To enable NPIV on all other Brocade Fibre Channel Switches, use the following
Fabric OS CLI procedure:
To specify the number of virtual N_Port_IDs per port or per switch, use the
configure command with either of the following parameters:
Example:
switch:admin> switchdisable
switch:admin> configure
Configure...
Fabric parameters (yes, y, no, n): [no]
Virtual Channel parameters (yes, y, no, n): [no]
F-Port login parameters (yes, y, no, n): [no] y
Maximum logins per switch: (1..4032) [4032] 2048
Maximum logins per port: (1..255) [255] 126
.
.
switch:admin> switchenable
Cisco switch
Cisco Fibre Channel switches running SAN-OS 3.0 or later will support NPIV. To
enable NPIV on Cisco Fibre Channel Switches running the Cisco Device Manager, use
the following procedure:
From the Cisco Device Manager, click Admin, and then select Feature Control.
The Feature Control window appears.
Click the row titled NPIV.
McDATA switch
McDATA Fibre Channel switches with E/OS 8.0 or later will support NPIV. McDATA
switches require an optional license to enable this function. Use the following
procedure to apply this license and enable NPIV:
From a browser, open the web user interface for the McDATA switch that is to be
connected to the VC-FC module. The Node List view details the devices attached to
the McDATA switch.
To install the NPIV license, click Maintenance, and then select Options
Features.
Enter the license key for NPIV in the Feature Key field. Select the key as the
"N_Port ID Virtualization (NPIV)." Link from the window and apply the key by
clicking OK. A check mark in the left window indicates that the N_Port ID
Virtualization key is installed.
Click Enable.
In the Login column, set the value to 17 or higher for each port connected to
the VC-FC to ensure proper operation.