Anda di halaman 1dari 21

SOR for CPCL ELECTRICAL WO

Sl.No.

1
1.000
132.000
133.000

134.000
135.000

136.000
137.000
138.000
139.000
140.000
231.000
303.000
304.000
305.000

306.000

307.000

308.000
309.000
310.000
311.000
312.000
313.000
314.000
315.000
316.000
317.000
318.000
319.000

320.000
321.000
322.000
323.000
324.000

325.000

326.000
327.000
328.000
329.000
330.000

331.000
332.000
333.000
334.000
335.000

336.000
337.000

338.000
339.000
340.000
341.000
342.000
378.000
388.000
389.000

390.000

391.000

392.000
393.000

394.000

395.000

396.000

397.000
398.000
399.000
400.000
401.000
402.000
403.000

404.000

405.000
406.000

407.000

408.000
409.000
410.000
411.000
412.000
413.000
414.000
415.000
416.000

417.000

418.000
419.000

420.000
421.000

422.000

423.000

424.000

425.000
426.000

427.000
428.000
429.000
430.000
431.000

432.000

433.000

434.000
435.000

436.000

437.000

438.000

439.000

440.000

441.000

442.000
443.000

444.000

445.000

446.000

447.000

448.000

449.000

450.000

451.000
452.000

453.000
454.000
455.000

456.000
457.000
458.000
SOR for CPCL ELECTRICAL WORK
Item Description

2
CPCL 42 IN PIPELINE - SUPPLY (Group B)
B ELECTRICAL WORKS

SAFETY EQUIPMENT Supplying the following Safety Equipment as per directions of Site Engineer / Engi
RUBBER HAND GLOVES : Rubber hand gloves suitable for 11/6.6 KV operation with ISI mark.
INSULATING MATS: Supply & installation of 2000 mm X 1000 mm and of thickness as mentioned below, ap
insulating Elastomer mats as per specifications.
Insulating Elastomer mats conforming to IS 15652:2006 of thickness 2 mm (Class A) Electrical
Insulating Elastomer mats conforming to IS 15652:2006 of thickness 2 .5mm (Class B) T&I
Supply of fully charged CO2 fire extinguishers as per specifications (4.5 kg capacity as per IS: 2878 latest)
Supply of fully charged CO2 fire extinguishers as per specifications (2 kg capacity as per IS: 2878 latest)
Supply of fire buckets mounted on stand
CPCL 42 IN PIPELINE - SERVICES (Group B)
B ELECTRICAL WORKS
<H>(A) External works</>

CABLE TRENCH: Excavation in unpaved areas of earth in work sites for conventional cable trenches
1.5 metres including shoring, strutting etc. (if necessary), backfilling the trench with excavated
directed by Site Engineer, including all labour and materials complete as per drawings, spec
directions of Site Engineer. Elect:,,2100 ,,m3 T&I:,,,,17100,,m3

WBM Road/concrete breaking for cable trenches including required shoring strutting etc., and repair
road/dyke to original condition and disposing off excess materials (within the work site) a
specifications and direction of the Site Engineer, job complete in all respects including the cost
tools, materials, load, lift hire charges of equipments, if any. Elec: 40 (including excavation f
cables from existing feeders) T&I: 100

Cable Laying:,,Laying of all type of cables LT (PVC / XLPE / Armoured/ Unarmoured/Power/ Control/
trenches, in cable racks, in trays, in protective pipes, poles,columns, in conduits, in panels and
etc.;including the supply and installation of all required materials such as fixing clamps ,screw
tags etc. as required (other than the supply of the conduits, cables, pipes, cable racks, trays,
structures and panels) complete in all respect, including cost of all labour, tools, consumable
and cutting the cables in required lengths as per drawings, specification and directions of Site
Engineer-in-Charge,,,,,,,,,,,,,,,,,, ,,,,,,,,,,,,
Cable having outer dia upto 20 mm Elec
Cables having outer dia b/w 20 to 40 mm Elec
Cables having outer dia b/w 40 to 60 mm Elec
Cables having outer dia above 60 mm Elec
Copper control cable : OD upto 20 mm Elec
Cables having outer diameter upto 20 mm. T&I
Cables having outer diameter between 20 to 30 mm. T&I
Cables having outer diameter between 30 to 40 mm. T&I
02 Pair PVC insulated copper conductor u
Cat-06 LAN cable in 16 mm / 25mm / 32 m
5 Pair Armoured PIJF Underground Telepho
GI Pipe Supply, erection & installation of cable conduits made up of GI pipes of medium class 'B' s
owner's approval in trenches (already made), on walls, concrete structure etc., including supply an
of all the necessary pipe fittings such as bends, sockets, elbows, tees etc., bending, threading, b
clamping, providings, spacers, plugs, packings, bushings etc., as required Job complete in all res
the cost of all labour, tools, material etc. and as per specifications and directions of site engi
in-Charge.
a.,,25 mm Electrical,,:,,40 T&I,,,,,,:,,100
a.,,37 mm Electrical,,:,,40
a.,,50 mm Electrical,,:,,40 T&I,,,,,,:,,100
a.,,60,,mm Electrical,,:,,60 T&I,,,,,,:,,200

Supply, fabrication, erection, installation of steel structural works of any type and shape such as
cable trays, push button control posts etc., as required job complete in all respects including th
labour, tools, material etc., complete.and as per specifications and directions of site engineer/ E
Charge.

Connection and testing of 415 V AC 3 phase / 230 V AC single phase motors (including space heaters/thermistors wherever
Actuators including execution of terminal connection of control and power cables, earthing of the motor/actuator/ connec
installing the controller in LT panel, earthing the motor frame, armour etc. as per the drawings, erection manuals, and as pe
Engineer. Job complete in all respects including the cost of supplying and installation of all the required FLP/WP cable gland
adapeters, end lugs, GI earthing wire / strips, labour, tools, materials, etc., as required in all respects for all types of
motors/heaters/thermistors/actuators etc.
Capacity upto and including 1 KW
Capacity over 7.5 KW but upto 50 KW.
Capacity upto and including 1 KW
Capacity above 7.5 KW but upto 50 KW

<H>LT Panel:</> Erection, installation including within site transportation, testing and commission
owner supplied power-control- centres, motor control centres , soft starters, APFC panel etc. assem
required, installation on the already made foundation channels, aligning, levelling, grouting, asse
all the inter connections /outgoing/incoming power & control cable/ bus duct connection including m
cable entries as required as per drawing, specifications and directions of the Site Engineer/Engine
including cost of all materials, tools labour etc. complete in all respect including termination of
control cables, installation of thermistor controller, internal wiring, earthing of LT panels, supp
glands etc.complete as per cable schedule, drawings etc. ",,,,,,,,,,,,,,,,,,,,,,,,,,,,,, .
Capacity over 1 KW but upto 2.5 KW.
a) Weight of unit upto and including 100 Kg.
c) Weight of unit above 500 kg but upto and including 1000 kg
Capacity over 2.5 KW but upto 7.5 KW.
<H>CORROSION MONITORING PROBE</> Installation of Corrosion Monitoring Probes including Flareweld a
accessories complete in all respect under the supervision of Site Engineer. The Job complete all re
materials, tools, tackles and consummables
C INSTRUMENTATION WORKS
Installation, testing and commissioning of Pressure Indicator (PI) of various ratings as per direc
Engineer in-charge/ Site engineer and Drawings.
ChPT Landfall Point
CPCL Manali Ref SRB Area

As built documentation for each station covering a)Control /signalling cable layout drawings b)Cable trench details c)Cable
d)Earth grid layout e)Field instrument termination details f)Panel foundations details g)Cable schedule h)Junction box wirin
resistivity measurement data j)Field panel termination details k)Completed work reports formats daily activity report l)Calib
instruments tested as per scope m)OTDR traces of OFC laid in stations.
ChPT Landfall Point
CPCL Manali Ref SRB Area
CPCL 42 IN PIPELINE -COMPOSITE (Group B)
B ELECTRICAL WORKS

Supply, installation and fixing of Prefabricated perforated GI Cable trays of width 150 mm, 300 mm, 450 mm & 600 mm as p
requirement for laying of cables with standard run spacings. Load in Kg/Mtr for support span of 2.5 Meter as 30, 60, 75 & 9
concentric static load as 70 Kg at the centre. The work including all accessories for fixing on concrete / wall /structures etc.
site engineer.

Supply, installation & fixing of prefabricated perforated Aluminium cable trays of width 150 mm, 30
600 mm as per site requirement for laying of cables with standard rung spacings. Load for support s
as 30, 60, 75 & 90 (in Kg/Mtr) respectively with concentric static load as 70 Kg at the centre, wit
labour, tools and tackles, consumables etc , as per drawings, specification and directions of Sit
Engineer-in-Charge

<H>High Mast </> Supply, erection, testing and commissioning of raising /lowering type high mast to
Bajaj/Philips make (heavy duty type) including specifically designed integral High mast luminaire t
Bajaj make or equivalent Philips make and supply of requisite SON-T lamp per mast of Bajaj/Philips
control gears. The mast tower system shall be totally hot dip galvanized as per BS 729 and suitable
velocity as per IS-875. The high mast shafts shall be in suitable sections and with additional diap
for individual sections and will be stress fitted at site. Tower system includes headframes, stainl
rope (7/19), double drum winch ,galvanized lantern carriage. Item includes supply of all required m
including cabling from base to the fittings with Junction Box at the Top etc. and carrying out the
for the high mast as per approved design, providing set of two neon spiral type aviation obstructi
timer, fixing,wiring the light fittings and lamps etc. Supply & installation of 3-phase flameproof
suitable for electrical operation of raising and lowering the lantern carriage, special winch gear
simultaneous and reversible operation of double drum winch, supply and erection of flameproof, weat
control panel with 4P, 32A, MCCB as incomer, supply and erection of hot dipped galvanized lightning
per mast), including termination of power cables & earthing of High Mast, , with materials, labour,
tackles, consumables etc, as per drawings, specification, mast manufacturer guidelines and directi
Engineer / Engineer-in-Charge. Note: High mast manufacturer's assistance shall be taken for carryin
erection and commissioning work at no extra cost to the owner. ,,,,,,,,,,,,,,,,,,,,,,,,,,,, 20 M Hi
Nos. 2x400 W SON-T lamps
<H>(A) External works</>

<H>SAND SUPPLY & FILLING :</> Supplying and spreading of approved quality fine dry river sand in ca
including the cost of all material, transport, load and lift charges, labour, tools and tackles, co
as per drawings, specification and directions of Site Engineer / Engineer-in-Charge Elec: 300 M3

BRICK SOLING : Supply and laying of approved quality 75 mm thick second class brick flat soling wit
in the interstices, in cable trenches for protectionincluding the cost of all brick and sand, labou
charges, tools and tackles etc, as per drawings, specification and directions of Site Engineer / E
Charge Elec: 850 M2 T&I: 11400 M2

MS CABLE MARKER Supply, erection & installation of MS cable markers, including excavation, installa
markers, cement concrete grouting, backfilling, materials, labour, tools and tackles, consumables e
drawings, specification and directions of Site Engineer / Engineer-in-Charge Elec:,,100 T&I:,,,,57

LT Cable joint (1.1 KV): Making straight through joints on Al/Cu conductor XLPE/PVC insulated ar
including the supply of required materials such as cable jointing kit (of heat shrinkable sleeve ty
Raychem/Mseal/3M) , materials, labour, tools and tackles, consumables etc , as per drawings, speci
directions of Site Engineer / Engineer-in-Charge
LT Cable
Cable having outer dia upto 20 mm
Cables having outer dia b/w 20 to 40 mm
Cables having outer dia b/w 40 to 60 mm
Cables having outer dia above 60 mm
Copper control cable size upto 6 core x 1.5/2.5/4 sqmm

EARTH ELECTRODES Supplying, installation, testing of GI earthing electrode, including the supply an
of the CI cover, charcoal /special backfill etc. and construction of chamber; complete as per draw
,specifications and directions of the Site Engineer, Including the cost of all labour, tools, ma
complete in all respects.
EARTHING PLATE : Supply & Installation of G.I. earthing plate as per drawing no. 9200-99900-404-009-00 outside the buildi
includes grouting of the plate as shown in the drawing. The item should be complete in all respect including all materials, t
and as per direction of EIC / Site engineer.
EARTH PITS (T&I)

Supply, installation, testing of earthing system consisting of <H>6 earth pits </>of perforated GI
electrodes and copper plate terminal block including construction of chamber using cement concrete
pit cover and frame, supply of charcoal, salt etc including supply of interconnecting cables / stri
necessary welding etc complete as drawings, specifications and directions of the site engineer, inc
tools, materials etc complete in all respects as per drawing The job shall also include testing of
and the entire earthing system on whole. Note: Earthing for field instruments shall be provided fro
grid covered in Electrical SOR..

EARTH STRIP / WIRE / ROPE / CABLE Supply, installing and testing of earthing strip/wire/rope/ cable
making the earthing grid system by supplying, laying the GI / Cu strip and making all the necessa
joints, connecting to the earthing electrodes and existing earthing grid etc., complete as per d
specifications and directions of the Site engineer/Engineer-in-charge, including the cost of all la
materials, etc. complete in all respect. ,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,
50 mm X 6 mm G.I. earthing strip
40 mm X 5 mm G.I. earthing strip
25mm x 4 mm copper flat
25 mm X 3 mm Copper flat (T&I)
GI Wire / GI Rope ( 8 SWG ) Electrical,,,,200 M T&I,,,,,,,,390 M
Copper cable as per spec -100 mm2 Electrical,,,,200 M T&I,,,,,,,,150 M
GI wire / rope 35 sq. mm
GI wire / rope 10 mm diameter

<H>FLAME PROOF FITTINGS </>: Note: All equipment under this category shall be suitable for location in zone-I gas group I
class T3) area with a separate terminal box for incoming cable and a separate terminal box for out going cable (where appli
separate enclosure for each equipment including control gear etc. in IP 65 cast aluminium LM-6 certified enclosure.

<H>FLP/WP PUSH BUTTON STATION</> : Supply ,erection,testing and commissioning of FLP/WP push button
station of approved make with /without ammeter for the motor off control at field including connec
termination of copper control cable, fabricating, earthing the supporting structure, painting the s
supply & installation of double compression cable glands & flame proof plugs for sealing all spare
including the cost of all labour,tools, materials etc. complete in every respect as per the specifi
directions of the Site Engineer/ Engineer-in-charge.
b) Without Ammeter
<H>FLAME PROOF LIGHT FITTINGS :</> Supply erection , installation , testing and commissioning of flame proof light fitting
make alongwith flame- proof control gear box containing ballast & condensor and lamp, including fixing on walls,columns,
etc. as required ,grouting clamping , supporting including fabrication and installation of clamps, nuts, bolts ,earthing with 8
connecting the lamps, cable terminals at the light fittings, including supply & installation of double compression cable gland
plugs for sealing all spare entries etc.complete as per drawings, specifications and directions of Site Engineer / Engineer-in-
the cost of all labour ,tools, materials etc. complete in every respect.
a) 250 W HPMV/HPMH flood light fitting, fixture with built in choke, lamp complete Model as per Appendix-1

<H>FLP/WP EXHAUST FANS :</> Flame proof, weather proof, single phase, 12" exhaust fan, IP65, LM6 type EF1001 of FCG o
alongwith supporting frame, bolts, louvers, flame proof motor, including supply & installation of double compression cable
proof plugs for sealing all spare entries, complete in all respects
<H>SHOCK TREATMENT CHART </>: Supply and installation of shock treatment chart framed in good quali
English / Hindi / Local Language).
CAUTION BOARD : Supply and installation of vitreous enamel caution boards suitable for 440 V/11KV/
IS 255 including fixing on the wall with all the required hardware etc. complete in English / Hindi
Language.

<H>STAINLESS STEEL INSCRIPTION PLATE </>: Supply and installation of approved quality stainless steel name inscription p
anodising, engraving the inscriptions, providing screws, etc. for equipments viz. motors, motor control centres, switchgears
stations etc. as required, providing necessary holes tapping etc. and fixing the same complete in all respect as per the direc
Engineer/Engineer-in-charge including the cost of all labour, tools etc.
<H>INTERNAL WORKS </>

Supplying, installation and testing with 1.5 Sq.mm stranded PVC insulated copper conductor wires fo
neutral of 650V grade including earthing by providing 1.5 Sq.mm earth insulated continutity wire of
conduit (Supply & installation of PVC conduit covered elsewhere in SOR) recessed on wall/ceiling/ f
including supply & installation of switch boxes,junction boxes, pull boxes, bushes, screws, check n
modular switches and sockets . The circuit wiring with 4 Sq.mm PVC copper wire from D.B. to switch
required is also in the scope of the contractor.,,,,,,,, ,,,,,,,,,,,,,,,,,,,,,,
1 light point controlled by 1 modular sw
2 light point controlled by 1 modular sw
3 light point controlled by 1 modular sw
4 light points controlled by 1 Modular s

Wiring with PVC insulated 2.5 sqmm copper conductor wire for fan points (1 fan point controlled by 1 modular switch) inclu
space for electronic regulator in switch box , providing and fixing fan hook in the ceiling as per specifications and drawings.

Wiring with PVC insulated 2.5 sqmm copper conductor wire for phase & neutral , 650 V grade including earthing , the third
copper conductor earthing insulated continuity wire for exhaust/ wall bracket fan including providing and fixing of 5 pin 6 A
and 10 A modular switch near the door or as as per specifications and drawings. The circuit wiring shall be with 4 sq. mm P
from switchboard to 1st <H>exhaust fan</> for multiple exhaust fans in one circuit.

Wiring for 250 V single phase and neutral 16 amps modular power plug point with PVC insulated 4 sq
conductor wires for phase & neutral, 650 V grade including earthing, the third pin with 2.5 sq. mm
earthing insulated continuity wire, complete with providing and fixing of 6 pin 16/6A modular socke
modular switch (1 plug point per circuit) as per specifications and drawings

Wiring as in item no. 1 for 250 V single phase and neutral 6 amps modular plug point with PVC insulated 2.5 sq. mm. coppe
for phase & neutral, 650 V grade including earthing, the third pin with 1.5 sq. mm copper conductor earthing insulated con
complete with providing and fixing of 5 pin 6A modular socket and 10 A modular switch (1 plug point per circuit) as per spe
drawings. The circuit wiring shall be with 4 sq. mm PVC copper wire from switchboard to 1st plug point for multiple exhaus
circuit.
Point wiring for power plug point with 4 sq.mm stranded PVC insulated copper wire including earthing the third pin with 2.
insulated earthing wire complete with supply and fixing of recessed mounted industrial type 3 pin 32 A metal clad socket a
(Motor duty) housed in a 16 gauge M.S. Box
Wiring as in item no. 1 for call bell points (1 call bell point controlled by 1 modular switch)in switch box including providing
suiable for single phase 230 V as per specifications and drawings.

Wiring as in item no. 1 for 250 V single phase and neutral 6 amps modular plug point with PVC insulated 2.5 sq. mm. coppe
for phase & neutral, 650 V grade including earthing, the third pin with 1.5 sq. mm copper conductor earthing insulated con
complete with providing and fixing of 3 numbers, 6 A 5 pin modular sockets and 10 A modular switches for UPS point as pe
drawings.

<H>Lighting Distribution Board / AC Distribution Board</> Supply , installation, testing and comm
lighting / AC Distribution board of approved make as per appendix -1, with rating and feeders as p
specification. The DB shall be of IP-42 protection class and shall conform to IS 8623. The board sh
with an acrylic door as per specifications and drawings
Type IV DIstribution Board : Double Door Translucent Euro DB of Havells or approved make as per appendix -1, having 100
bar, 1x63 A TPN MCB , 1x63 A RCCB (100 mA Sensitivity), 9x6A SP MCB & 6x20 A SP MCB as per specification
Type V Distribution Board : Double Door, EURO DB of Havells or equivalent approved make having 200 A TPN Bus Bar, 1 x 1
1x100 A FP RCCB (100 mA Sensitivity), 9x32 A SPN Motor duty MCB as per specification
Critical Light DB : Euro DB DBOXx of Havells or equivalent make complete with bus bar, neutral links, earth links and 1 x 6 A
SPN MCB
<H><U>Fittings & Fixtures</></>

<H>Decorative Light fittings</> Supply, installation, connection, earthing and testing of the following fittings,including supp
of drop pipes, hooks, fittings, fixtures, nuts,bolts, supports, on walls, outlet box for regulators and all other required materi
specifications, drawings and directions of the Site Engineer including cost of all labour, tools, materials etc. complete in all r
the fittings can be the make mentioned in the respective SOR items or equivalent model from the approved make list given
specifications.

Tube light fitting type TBS 869/414 of PHILLIPS make complete with 4 x 14 w TL5 lamps, all accessories such as T5 lamps, el
capacitor, spring loaded rotor type lamp holders, starter, connector blocks etc, suitable for mounting in false ceiling

Tube light fitting type TPH 824/228 D8 DI HF of PHILLIPS make complete with 2 x 28 w T5 tubes, all accessories such as T5 l
ballast, capacitor, spring loaded rotor type lamp holders, starter, connector blocks etc. The fittings shall be provided with su
accessory / wall mounting bracket depending upon directions by EIC / Site Engineer

Tube light fitting type TMS 122/228 HF (with GMS 122/228 R) of PHILLIPS or approved make as per app
complete with 2 x 28 w TL5 tubes, all accessories such as TL5 lamps, electronic ballast, capacitor
rotor type lamp holders, starter, connector blocks, reflector etc.
Tube light fitting type TMS 122/128 (with reflector GMS 122/128 R ) of PHILLIPS or approved make as per appendix -1, com
TL5 tube of Philips make and all accessories such as electronic ballast, capacitor, spring loaded rotor type lamp holders, sta
blocks, reflector etc.

Tube light fitting type FCS 518 /218 of PHILLIPS make complete with 2 x 18 w CFL tubes, all access
electronic ballast, capacitor, spring loaded rotor type lamp holders, starter, connector blocks etc
Bulk head light fitting type FXC 101 (Grey, Clear) of PHILLIPS or approved make as per appendix -1, complete with 1 X PLS 9
other accessories etc.
Post top lantern type SPC 201 /70(I) LPF of PHILIPS make complete with including pole, 1 x 70w (I) SON lamp , luminaries w
& civil works like foundation etc. as per specifications & instruction of manufacturer and as per direction of EIC.
Ceiling fan with electronic regulator & other accessories and fittings etc. of or approved make as
with the following sweep size:- 56" Sweep
<H>Exhaust fan</> Supply, installation, testing of single phase 230 V, industrial type heavy duty exhaust fan of GEC/Usha/C
or of approved make as per appendix -1 fitted/ provided with louvres, supports etc. including making the required opening
and connecting the wires etc. including earthing the body of the fan, making good the opening on the wall etc. complete a
drawings and direction of Site Engineer including the cost of all labour, tools, materials etc. complete.
18" Sweep
18" Sweep

<H>PVC Conduit pipes</> Supply, installation, fixing in position, PVC conduit pipes, of ISI marked
brick work etc. during or after construction by making grooves in the wall, ceiling etc. cutting th
jointing the pipes with PVC couplers, providing necessary tees, bends, junction boxes etc. with 12
inside conduit without joint for concealed wiring, including making good the concrete, brick work,
complete as per drawings and direction of Site Engineer / Engineer-in-charge including cost of all
materials etc.
i) 19 mm
ii) 25 mm
iii) 32 mm

NOTE:1.the quoted price inclusive all applicable vat & tax & duties except service tax.
2. All the quantity are tentative. The final payment basic on the actual quantity confirm by Contractor.
Quantit Rate Amount
Units
y (RS) (RS)
4 5

4 SET

12 EA
10 EA
4 EA
4 EA
4 EA

19200 M3

140 M3

480 M
2600 M
200 M
4800 M
400 M
6350 M
1650 M
3400 M
1500 M
2000 M
500 M
140 M
40 M
140 M
260 M

6030 KG

3 EA
4 EA
4 EA
4 EA

200 KG
800 KG
1000 KG
1200 KG

2 EA

7 EA
4 EA
1 SET
1 SET

200 KG

5960 KG

2 EA

2580 M3

12250 M2

670 EA
2 EA
2 EA
2 EA
2 EA
2 EA

30 EA

20 EA

2 SET

200 M
40 M
60 M
100 M
590 M
350 M
60 M
200 M

4 EA
2 EA

2 EA

4 EA

4 EA

4 EA

10 EA
10 EA
4 EA
4 EA

12 EA

10 EA

10 EA

10 EA
5 EA

1 EA

4 EA

4 EA

1 EA

2 EA

24 EA

12 EA

16 EA

4 EA

4 EA

2 EA

4 EA

12 EA
6 EA
2 EA

200 M
200 M
100 M