Anda di halaman 1dari 1

Flange Leakage Check

Nozzle Details Mean Dia. of


Resultant Equivalent Allowable Result
Sr. Node Pressure Temperature Axial Force Gasket Contact Condition /
Line No. Moment Pressure Pressure (Flange Leakage
No. No. Size Rating face Case
Check)
(Inch) (#) (Kg/cm2g) (Deg F) (N) (N-m) (mm) (psig) (psig)
1 10 14 150 11.6 368 2021 2256 389 195 210 Case -1 PASS
2 10 14 150 9.6 341 1798 2021 389 164 218 Case -2 PASS
3 10 14 150 0.5 374 2098 2325 389 39 208 Case -3 PASS
4 100 10 150 11.6 368 5940 4965 302 309 410 Case -1 PASS
5 100 10 150 9.6 341 5284 6011 302 307 218 Case -2 FAIL
6 100 10 150 0.5 374 5679 4822 302 147 208 Case -3 PASS
7 150 10 150 11.6 368 17 851 302 187 210 Case -1 PASS
8 150 10 150 9.6 341 10 760 302 157 218 Case -2 PASS
9 150 10 150 0.5 374 337 848 302 30 208 Case -3 PASS
Notes :
1) Gasket dimensions are as per ANSI B 16.20
2) Allowable Pressure is as per "Pressure-Temperature" Chart from ANSI B16.5.
3) This table is prepared based on ASME Section III, Paragraph NC-3658.1.
4) All values of Static output results (Force & Moments) for different cases are considered for the calculation.
6) The formula used to calculate the Equivalent Pressure is as follows :
Peqv = Pd + 4*F/3.14*G2 + 16*M/3.14*G3
where ; Pd = Internal Pressure
F = Axial Force
G = Mean Diameter of Gasket
M = Resultant Bending Moment
7) Units have been converted suitably.

Case -1 Design Case


Case -2 Operating Case
Case -3 Occasional Case