CORTEC

Ordering information

Variants Order No.


MVAJ - High/Low Burden Tripping Relay MVAJ
Number of Contacts
Five 0 5
Ten 1 0
Twenty 2 0

Contact Mechanism
Self Reset (5 & 10 Contacts Only!) 1
Self Reset (Delayed 2s) (10 Contacts Only!) 2
Hand-Reset 3
Electrically-Reset 4
Hand & Electrically-Reset 5

Case
Size 2 (5 & 10 Contacts Only!) - Blue/Grey livery J
Size 4 (20 Contacts Only!) - Blue/Grey livery L
Size 2 (5 & 10 Contacts Only!) - Grey/Grey livery R
Size 4 (20 Contacts Only!) - Grey/Grey livery T

Flagging
Standard Hand - Reset Flag A
Following Flag B

Voltage (Nominal)
24/27 Volts 0 0
30/34 Volts 0 2
48/54 Volts 0 5
110/125 Volts 0 8
220/250 Volts 1 0

Contact Combinations
5 Contact Versions
5 Normally Open 0 0
4 Normally Open/ 1 Normally Closed 0 1
3 Normally Open/ 2 Normally Closed 0 2
2 Normally Open/ 3 Normally Closed 0 3
4 Normally Open/ 1 Normally Open - internally wired for RESET cut off (MVAJ054/5R*08** variants ONLY!) 9 1
2 Normally Open/ 2 Normally Closed/ 1 Normally Open - internally wired for RESET cut off (MVAJ054/5R*08** variants ONLY!) 9 2
1 Normally Open/ 3 Normally Closed/ 1 Normally Open - internally wired for RESET cut off (MVAJ054/5R*08** variants ONLY!) 9 3
3 Normally Open/ 1 Normally Closed/ 1 Normally Open - internally wired for RESET cut off (MVAJ054/5R*08** variants ONLY!) 9 4
10 Contact Versions
10 Normally Open 0 0
8 Normally Open/ 2 Normally Closed 0 2
6 Normally Open/ 4 Normally Closed (MVAJ101R*08** variants OR MVAJ103/4/5 ONLY!) 0 4
4 Normally Open/ 6 Normally Closed (MVAJ101R*08** variants OR MVAJ103/4/5 ONLY!) 0 6
2 Normally Open/ 8 Normally Closed ( Not MVAJ101/2 !) 0 8
20 Contact Versions
20 Normally Open 0 0
18 Normally Open/ 2 Normally Closed 0 2
16 Normally Open/ 4 Normally Closed 0 4
14 Normally Open/ 6 Normally Closed 0 6
12 Normally Open/ 8 Normally Closed 0 8
10 Normally Open/ 10 Normally Closed 1 0
8 Normally Open/ 12 Normally Closed 1 2
6 Normally Open/ 14 Normally Closed 1 4
4 Normally Open/ 16 Normally Closed 1 6

Issue
Factory Defined *

Page 2 of 8 427431379.xls 07/09/2019


Configurator

MVAJ Tripping Relay High or Low Burden


To enable only current variants to be offered, please specify ACTUAL or REQUIRED delivery date here
Format = dd/mm/yy (where d=day, m=month, y=year)
Digit No 1-4 5-6 7 8 9 10 - 11 12 - 13 14

PCS VARIANT MVAJ ** * * * ** ** A


TRIPPING RELAY
HIGH or LOW BURDEN
Number of Contacts
Select ONE of ...
Five **
Ten
Twenty
Contact Mechanism
& Reset Time Delay
Select ONE of ...
Self - Reset
Self - Reset (Delayed 2s) *
Hand - Reset
Electrically - Reset
Hand &
Case Electrically - on
(Dependant Reset
number of contacts)
Select Number of Contacts First *
Flagging
Select ONE of ...
Standard Hand - Reset Flag *
Following Flag
Nominal Supply Voltage
Select ONE of ...
24/27 Volts
30/34 Volts **
48/54 Volts
110/125 Volts
220/250Contact
Output Volts Configuration
Select - Normally Closed
Select all other attributes FIRST

**

Calculated - Normally Open


? - Normally Open
Issue A

Page 3 of 8 427431379.xls 07/09/2019


Master Text

MASTER TEXT
MVAJ*********A
MVAJ - High/Low Burden Tripping Relay
Nominal Supply Voltage :
Select ONE of ...
Contact Mechanism :
Select ONE of ...
Contact Configuration :
?-Make, ?-Break
Flagging :
Select ONE of ...
Special Instructions :

After test external link(s) MUST be fitted between case terminals ? & ? as detailed in the test instructions.

DOCUMENTS

Wiring/Circuit Diagram :
01MVAJ***01 SHT 1
Customer Diagram :
01MVAJ***01 SHT 1
Wiring Schedule :
02MVAJ***01 SHT 1
Outline Wrapper :
GJ0025 SHT ?
Test Specification :

Page 4 of 8 427431379.xls 07/09/2019


BOM

PCS MATERIAL Qty.


NUMBER DESCRIPTION
MASTER Required
MVAJ*********A
Aux Unit 1 #N/A #N/A #N/A
Aux Unit #N/A #N/A
Coil #N/A #N/A
Contacts #N/A #N/A

Page 5 of 8 427431379.xls 07/09/2019


Routing

Model No: MVAJ*********A


Ref Op Set: 50000154
Add Pre-production Ref. Op. Set 50000021
Add Inspection Characterisitics Op. 9000, 4

#N/A
#N/A
#N/A

#N/A 105BA Assemble & Wire #N/A Mins


50 105BB Product Check - Assy & Wire - Unit 5 Mins
#N/A 105BC Prep for Test #N/A Mins
80 105BC Customer Special Labels 0.6 Mins
85 105BB Product Check - Case,Cover & Labels 1 Mins
#N/A 105DB Auto Test #N/A Mins
1000 105BQ Final Inspection 3 Mins
9000 105BP Primary Packing 6.5 Mins

Page 1 of 1 427431379.xlsRouting 07/09/2019


Aux Unit FB0307???
Coil ZC0419???
Contacts FB03170??

New Aux Unit.Suffix (If Req'd)->

Copy From -------------->


#N/A
#N/A
#N/A

FB0307???.