Anda di halaman 1dari 1

24 23 22 21 20 19 18 17 16 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1

T
SECTIONS OF THE FIRED HEATER: T

TRUE R250.00
A A. Stack section
R R

B. Convection section

P P
2000.00 C, Radiation section
1000.00
N
D. Burner section N
150.00

M 1000.00 MECHANICAL DESIGN CONDITIONS M


Heater section Firebox Bank 1
COIL DESIGN:
Max. calc. film temperature °C 495 361
L Max. calc. tube metal temperature °C 496 362 L
250.00 COIL ARRANGEMENT:
Tube orientation Horizontal Horizontal
Tube material carbon steel
K Refractory material Alumina silicate composite K
Tube outside diameter mm 114.3 114.3
250.00 Tube wall thickness mm 6.02
Number of parallel flow streams 2 1
TRUE R57.15
J Number of tubes 8 36 J
Number of rows of tubes (conv. sect.) 6
B Number of tubes per path per row (conv. sect.) 6
Effective tube length mm 1200 1200
H 203.20 Bare tubes: Number 8 36 H
Total exposed surface m² 6.9 15.5
Extended surface tubes: Number
Total exposed surface m²
G G
Tube layout 90 in-line square

2000.00 C Tube spacing (cent. to cen. same row) mm 203.2 203.2


F F

E E
400.00
TRUE R70.00
IFR DATE: 2/20/2019 DESIGN PHASE:I FUPRE/DML REFINERY DESIGN PROJECT
D
8.56 1500.00 D
IGBAGARA P.W. UNIT: MM EFFURUN, DELTA STATE NIGERIA.
1500.00
ALAH, J. MATERIAL: SA51670 CAPACITY: 12.5 BARREL/DAY
C C
DESIGN ANI, C. TITLE: SERVICE:
WEIGHT:

BOILER FOR STEAM GENERATION HEAT WATER


ONOCHA, O CODE: HTFS
B B
D Osagie, O. SCALE: 1:8
DESCRIPTION:
PROJECTION: THIRD ANGLE
CHECK HEAT WATER TO 380 C
OLUMOR, E.O PLOT SIZE: A0 QUANTITY: 1

A APPRD. OLAYEBI, F. REV: NILL FILE NAME: BOILER3D TAG NO: STFM-5 SHEET 2 OF 7 A

24 23 22 21 20 19 18 17 16 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1