the placing of the reinjection diffuser a little above the bottom floor of the pond in order

to reduce turbulence in the LCZ layers and to avoid lifting of silt to the upper regions of
the pond depth which would affect the pond clarity and performance. However, the
practicality of achieving this desired result lies with the suitable design of brine
extraction diffuser, heat extraction system and brine reinjection diffuser and these
designs have been given in chapter 3. Hence with the simple design given above the
following pond dimensions have been obtained.

I. AREA:

a) Solar collection area of the pond at its top surface 497 m 2

(22.8 ra X 21º. 8m)

b) Solar collection area of the pond at its bottom Floor 353 m2

(19.3 m X18.3 m)

c) Solar collection area of the pond at LCZ-NCZ Interface 404 m 2

(20.6 ra X 19.6 m)
d) A free board (U.25m) the top peripheral
dimension and its area are (23.2 m X22.2 m)
and 515 m 2

II. ZONE THICKNESS


Thickness of UCZ = 0.25 m
Thickness of NCZ = 1.30 m
Thickness of LCZ = 0.90 m

III. TOTAL DEPTH OF THE POND = 2.45 m


IV. a. Expected Thermal power extraction from the pond = 500 Kwh/Day
b. Hot brine flow rate = 58.68 m3/Hr
c. Desired temperature drop across the heat exchanger = 8ºC
d. Assumed Average diurnal temperature rise of the pond = l°C/dav
e. Volume of brine stored in the LCZ (0.9m) = 346 m 5