Anda di halaman 1dari 3

Risk assessment form

Name of assessor Date

Time Work area Welding Shop in company Seven Oaks Engineering Private limited

Task being assessed

New risk
What is the Who might be How might Existing risk Risk rating Additional Action/ Action/
people be control rating monitored by monitored by
hazard? harmed? controls
harmed? measures (Residual) whom? when?
L C R L C R
Presence of welding Welders, Fire Employees may Local Exhaust 4 3 12 Ensure that the 2 3 6 Senior HSE Officer
fumes which can watchers, and other affected from any Ventilation is LEV is working at
cause respiratory personnel who are respiratory disese provided within the all times and no
disease, Chances of present in the due to welding workshop. Fire unauthorized
contact with molten workshop. fumes and serious blankets provided modifications are
materials causing burn may happend and made it done. Regular
burns. Chance of mandatory to use it. inspection of site
fire / explosion Fire watcher present and proper
in all locations housekeeping with
PPE

During lifting House keeping Load may collapse Risk assessment is 3 3 9 Ensure that a safety 2 3 6 Senior HSE Officer
chances of collision personnel, and those to the employees done for the lifting. personnel is present
which could lead to employees who are that may cause fatal Proper PPE is given during the lifting.
injury, inhalation of involved in lifting accident to all staffs. Ensure that
paint fumes to those activities. Employee may All employees to appropriate and
involved in painting, tripped with the load ensure that there are adequate
Slip Trip hazards that can cause no trailing exposed respiratory
while doing physical injury hazardously in the protection is given
housekeeping and major property work floor. to painters.
activities loss.
Risk assessment form

New risk
What is the Who might be How might Existing risk Risk rating Additional Action/ Action/
people be control rating monitored by monitored by
hazard? harmed? controls
harmed? measures (Residual) whom? when?
L C R L C R
Oxygen / Acetylene Workers working in Employee may Currently the area is 3 4 12 Permanent roof to 2 4 8 Senior HSE Officer
cylinders are stored the workshop and caught with fire that barricaded to be provided for the
in open area which anybody near the can cause serious prevent any cylinder storages
could lead to storage area burn injury,Major unauthorized entry area.
explosion due to property loss
high temperature.

Risk of fire being Major burns (third Inform all the 3 4 12 Separate areas for 2 4 8 Senior HSE Officer
spread to all areas Workers,superviors degree burns) to employees not to the storage of
because the access and anybody in the employees and fire obstruct the way to unwanted
to the fire pump was area and explosion of the the fire pump in the materials,Scraps
obstructed with equipments and pre- tour safety
unwanted material property may meeting
and it cannot be damage. The fire water
activated on timely supply valve was
manner. The main opened and a
fire water supply warning sign was
was closed installed stating not
to close the valve

Review date Signature