Min amb is specified as -10 degC, however, the plant is not suitable for this low ambient temperature. Therefore, the comp
Continuous fresh ventilation air of 22000 m3/hr is required.
Oil heater is required since minimum ambient < 10 degC.
Gas quality specified as 0.1 ppm by wieght, sales to refer contrating for discharge filter requirements.
CE/PED/ATEX requirements are specified, sales to refer to contracting/QA for the same.
Area classification as Class 2, IIC specified for instruments safety. Sales to refer design & QA for the same.
The suction gas contains CO2 & H2S(dry). However, in presence of water (H2O), the gas mixture will be corrosive, which ma
dew point). Also specified H2S content is 25ppm. The Client to ensure the max content of H2S shall not be incresaed than s
60/2
3 |2 30. 180.
FI
DE N
FO !! I
AL T
CO
N
IN R
NA R
TE
SE L
Y
IN
T
NA
US L
O E
NL
Y
Calculation of approx. Am3/hr
RPM 970
Sm3/hr 4247.527 Vol. efficiency (%) 79
Nm3/hr 4017.931
Methane 91.91
Propane 1.19
I butane 0.20
Butane 0.28
I Pentane 0.01
Pentane 0.01
Ethane 5.82
Hexane 0.01
N2 0.55
CO2 0.02
Neo penta 0.00
100
Required Nm3/hr 300
Suction Pressure (bara) 1.137
Suction temp (°C) 20
Corresponding Am3/hr 286.8634443832
D1 (m) 0.2244123003
D1 Corrected (m) 0.225
PR1 (Assumption) 3
D2 (m) 0.1299038106
D2 corrected (m) 0.15
PR2 (Assumption) 3
D3 (m) 0.0866025404
D3 Corrected (m) 0.09
A1 0.039760782
A2 0.0176714587
A3 0.0063617251
Crankcase press (bara) 19
RESULTS
Ps3 118.51
Pd3 301
(n-1)/n 0.29078
Ambient temp °C 30