Anda di halaman 1dari 1

®

Process Heating Solutions Worldwide

Food Processing
Clean In Place Industry Case History

Application:
A dairy plant experienced frequent and
Features and Benefits: costly failure of shell-and-tube heat
exchangers on their clean-in-place (CIP)
100% Steam Efficiency systems. The CIP system was pumped from
Low Maintenance the CIP tank through the heater to the CIP
circuit. Increased energy efficiency was also
Compact Design part of the decision to look for an alternative
Precise Temperature Control solution.

Process Conditions:
Liquid Flow Rate: 60 GPM
Temperature Rise: 90ºF
Steam Pressure: 45 PSIG
Liquid Pressure: 20 PSIG
Steam Flow Required: 2,322 lbs./hr.
RETURN
EDOCTSE

Solution:
STEAM
INLET
ESTCODE

CIP
TANK

Pick SC25-1 Sanitary Heater was installed


TO CIP
EDOCTSE

CIRCUIT prior to system pump to provide an


ESTCODE

instantaneous heat up of CIP solution. The


system was installed in the horizontal position
to allow for mounting at the pump located on
ESTCODE
floor level. Since the original installation three
other SC25-1 heaters have been installed as
shell-and-tube units failed.

AP-F10
730 South Indiana Avenue | West Bend, WI 53095
ph: 262-338-1191 | fax: 262-338-8489 | www.pickheaters.com | info1@pickheaters.com

Anda mungkin juga menyukai