Plant:

Location of port:

Clinker output 6000 TPH


Elevation: 250 Meter
Barometric pres: 10020 mmwg
Duct diameter 2.35 Meter
Area 4.3391071429 Meter²
Ambient Temperture 25 °C
Process Temperture 374 °C
Static Pressure -483 mmwg
Pitot tube Factor 0.84

Density of gas calculation

Air constituents %Vol


Oxygen 70
Carbon di oxide 30
Carbon mono oxide 10
Nitrogen 22

Density of gas 1.99002 kg/Nm^3


0.54 Kg/m^3

Dynamic pressure measurement

Avarage dynamic pressure 8.92 mmwg

Velocity 15.122177621 m/sec


Volume flow 236220.296150454 m^3/hr
Volume flow 91994.3021462004 Nm^3/hr
Mass flow 127558.959921245 kg/hr
Clinker Rate 6000000 kg/hr
Specific mass flow 0.0212598267 Kg/Kg Clinker
Specific gas flow 0.0153323837 Nm³/Kg Clk
FAN FLOW MEASUREMENT

Date:
FLOW MEASUREMENT
End