Figure 1
Figure 2
Plant
Sales Gas Header
Compressor
or Eductor
Flow Meter
Gas From
Condensate Return
Other VRU sites
to Storage Tank
2
Application Note
Vapor Recovery Units
Figure 4
Electrochemical Cell O2 Sensor
Cathode Anode
Electrolyte + -
Oxygen Permeable
Membrane
electrolyte solution. An oxygen permeable membrane Advantages of optical oxygen measurement in vapor
allows oxygen molecules to enter the cell where they recovery applications include the following:
react with the electrolyte creating a voltage response to the
changing oxygen level (figure 3). H2S and trace amounts • Greatly reduced maintenance compared to competitive
of BTEX gases can poison the electrochemical cell causing technology
drift, frequent recalibration and eventual death of the cell. • High measurement accuracy at low part-per-million oxygen levels
Often a sample line scrubber is installed upstream from • No poisoning by contaminant gases such as H2S
the electrochemical cell to remove the contaminant gases. • Ability to measure in the presence of condensed moisture
The scrubber adds to the maintenance and complexity of • Optical sensor fails "high" thus preventing a false sense of
the sample system. Condensed moisture can also create security in the measurement
measurement error by plugging the permeable membrane
of the electrochemical cell. Coalescing filters to block Figure 5
3
Application Note
Vapor Recovery Units
Barben Analytical recommends using our 4401OXY Figure 6
Contact Us
Manual Sample Calibration Panel
Gas Phase Oxygen Measurement
Model #: SCP-B-OXY-ACFM-BOS
BOS1 (0 to 4.2% O2)
BOS2 (0 to 25% O2)
Barben Analytical is a leading supplier of analytical mea- BOS3 (0 to 300ppm O2, 1000ppm overange)