Anda di halaman 1dari 4

CV of Mr. S.

Sajiv

WinStar Electromechanical LLC, Dubai

Skill Set
Testing, commissioning and maintenance engineer have 5+ years of experience.
Have knowledge in testing and commissioning of 400/220kV GIS/132/66/33KV
(GIS)11KV, 415V (AIS) substation, panel boards (high tension & low tension), generator,
motor, transformers (power & distribution), CT, PT, breakers, isolator , and all electrical
equipment.

DEWA Approved CT/VT Engineer

Career Profile

 Inspection of control and Relay panel, preparation of Test Report and cable
schedule for sub-station, power plant, and process plant.
 Testing and Commissioning of switchgear , Control & Relay panel for
Generator, Transformer,
 Testing and Commissioning of power control Centre and motor control centre.
 Knowledge on Transformer Protection, Transformer Differential Protection &
REF Protection, Bus bar protection, Motor protection, and synchronizing
scheme.
 Testing of CT, PT, CVT, Circuit breaker, switch gear and Power Transformer.
 Operation and Maintenance of Power Plant and sub-station.
 Trouble shooting of all Electrical circuits, control and protection circuits.
 Troubleshooting and Quick Analysis of Power Systems. Commissioning of the LV -
MV AC Drives & DC drives

Key Projects Handled


Projects Executed in UAE

 33/11kV Ain Al Faydha B – AADC


 CT and VT testing.
 Testing of Auxiliary relays and voltmeters.
 33/11kV SAFIA SS – FEWA
 CT and VT testing.
 Verification of 11kV Schemes.
 Testing of Auxiliary relays and voltmeters.
CV of Mr. S.Sajiv

WinStar Electromechanical LLC, Dubai


 132/11kV Garden Toweer Substation - DEWA
 CT and VT testing.
 Verification of 11kV Schemes.
 Testing of Auxiliary relays and voltmeters.

 132/11kV Sahil Substation - DEWA

 Internal Verification of 11kV Schemes.


 Supporting for the GIS testing with manufacturer
 Internal testing of Auxiliary relays and voltmeters.
 Supporting of CT and VT testing.

 132/11kV Deira Tower Substation - DEWA

 Internal Verification of 11kV Schemes.


 Supporting for the GIS testing with manufacturer
 Internal testing of Auxiliary relays and voltmeters.
 Supporting of CT and VT testing.

Projects Executed in Qatar


 Testing and Commissioning of 66kV GIS/11Kv/415V Substation (Project Phase-
XII) for QATAR General Electricity & Water Corporation Authority (KAHRAMAA),
Location: DOHA Industrial Board S/S through Larsen & Toubro Limited, QATAR
(DOHA).

 Testing and Commissioning of 132kV GIS/66 KV GIS/11Kv/415V Substation


(Project Phase-XI) for QATAR General Electricity & Water Corporation Authority
(KAHRAMAA),

Location: Old Airport Refurbishment S/S through Larsen & Toubro Limited,
QATAR (DOHA).

 Testing and Commissioning of 132kV GIS/11Kv/415V (Project Phase-XII)


CV of Mr. S.Sajiv

WinStar Electromechanical LLC, Dubai


Location: Birkat Al Awamer-1, S/S through National Contracting Company,
QATAR (DOHA).

 Testing and Commissioning of 132kV GIS/11Kv/415V Substation (Project


Phase-XII)

Location: Ras Abu Fontas South, S/S through National Contracting Company,
QATAR (DOHA).

Projects Executed in India

 2*660MW Nigri Super Thermal Power Project. 400/11/3.3KV/415V &


275/225MVA GT,100MVA Station ,1.6MVA to 16MVA Distribution Transformer,
Switchyard , Switchgear Control & Protection scheme checking, testing of CT, PT,
Breaker (SF6
,VCB ), CBCT , Distribution Transformer & protective relays, cable schedule
preparation for Jaypee Cement Group, through M/s. Sigma Construction Pvt .Ltd ,
Nigri (Singruli),MP State.

 Installation and commissioning verify of overhead transmission lines up to 230 kV


on ISO, IEC & IE standard.

 Erection, Testing and commissioning of UG cables in various voltage levels.


 Charge of underground power transmission cable bonding, earthing &
insulation inspection.
 Co-ordinated Transformer testing: IR, voltage ratio test, magnetic balance test,
vector group test, magnetizing current test, SC current test, oil dielectric strength
test, resistivity, dielectric dissipation factor (Tan δ), flash point, ratio method,
lightning discharge or over voltage, sustained overloads.
 Inspection of power transformers; float operation, PRV operation, explosion
vent, OTI, WTI, conservator, breather, radiators, bushings, clearage distance,
load tap changer.

 Coordinated checks of transformer stability and sensitivity examination, winding


resistance tests (for all taps), vector relationship tests, transformer turns ratio test
(TTR), polarization index, winding insulation resistance test, core insulation
resistance test, polarity, secondary winding resistance, and insulation resistance
test, CT magnetizing (saturation current test), polarity, secondary winding
resistance, and insulation resistance test, zero phase sequence impedance test etc..

 Coordinated Testing and commissioning of CT’s,VT’s,VCB,SF6 breakers on gas


density switch test ,SF6,vaccum gas leakage test,SF6,vaccum gas purity test, IS bus
bar contact resistance measurement test, bus bar high voltage test,10kv isolation
test on ES with enclosures,SF6,vaccum circuit breaker timing test, earth switch
timing test, disconnecting switch timing test, and SF6,vaccum dew point test in GIS.
 Preparation of test reports and chart using QC tools for the electrical power
CV of Mr. S.Sajiv

WinStar Electromechanical LLC, Dubai


system equipment.
 Carry out root cause analysis, for process problems/deviation by means of different
techniques like cause affect analysis, failure mode effect analysis, why -why analysis
and point the process holder for corrective preventive actions for the deviation,
complex process NCR deviations.

Personnel Details
Educational Qualification : B.E (Electrical & Electronics Engineering)
Year of completion : 2012
Languages known : English, Hindi, Tamil & Malayalam

Anda mungkin juga menyukai